CAS 540-84-1
:2,2,4-Triméthylpentane
- 2,2,4-Trimethylpentan
- 2,2,4-Trimetil Pentano
- 2,2,4-Trimetilpentano
- 2,2,4-triméthyl pentane
- 2,2,4-トリメチルペンタン
- 2,4,4-Trimethylpentane
- ASTM ISO-Octane (2,2,4 Trimethylpentane) (Drum of 200 L)
- Iso-Ottano
- Iso-octano
- Isobutiltrimetilmetano
- Isobutyltrimethylmethane
- Isooctan
- Isooctane
- Isooktan
- Nsc 39117
- Pentan, 2,2,4-Trimethyl-
- Pentane, 2,2,4-trimethyl-
- Pentano, 2,2,4-Trimetil
- Trimethylpentan, 2,2,4-
- Trimetil Pentano, 2,2,4-
- Trimetilpentano, 2,2,4-
- Triméthyl pentane, 2,2,4-
- iso-Octane
- isooctane B&J brand 2.5 L
- イソオクタン
- Voir plus de synonymes
2,2,4-Trimethylpentane [for HPLC Solvent]
CAS :Formule :C8H18Degré de pureté :>99.0%(GC)Couleur et forme :Colorless clear liquidMasse moléculaire :114.232,2,4-Trimethylpentane
CAS :Formule :C8H18Degré de pureté :>99.0%(GC)Couleur et forme :Colorless clear liquidMasse moléculaire :114.232,2,4-Trimethylpentane [for Spectrophotometry]
CAS :Formule :C8H18Degré de pureté :>99.0%(GC)Couleur et forme :Colorless clear liquidMasse moléculaire :114.232,2,4-Trimethylpentane, ACS, 99+%
CAS :Solvent, thinner, in determination of fuel octane numbers2,2,4-Trimethylpentane is used as a solvent in spectrophotometric analysis and organic synthesis. Due to its high antiknock octane number, it is widely employed as a standard reference fuel for octane ratings. It acts as an entrainer in azeotr
Formule :C8H18Degré de pureté :99+%Couleur et forme :Colorless, LiquidMasse moléculaire :114.232,2,4-Trimethylpentane, Environmental Grade, 99.5+%
CAS :Suitable for pesticide residue analysis
Formule :C8H18Degré de pureté :99.5+%Masse moléculaire :114.232,2,4-Trimethylpentane, HPLC Grade, 99.7+%
CAS :Maximum level of impurities: Evaporation residue 3ppm, Chlorinated pesticides 5ppt, H2O 0.02%
Formule :C8H18Degré de pureté :99.7+%Couleur et forme :Colorless, LiquidMasse moléculaire :114.23Lead in Isooctane standard solution, Specpure™, 0μg/g(0.000g/gal)
CAS :This Thermo Scientific Chemicals brand product was originally part of the Alfa Aesar product portfolio. Some documentation and label information may refer to the legacy brand. The original Alfa Aesar product / item code or SKU reference has not changed as a part of the brand transition to Thermo Scientific Chemicals.
Formule :C8H18Masse moléculaire :114.232,2,4-Trimethylpentane, 99%
CAS :2,2,4-Trimethylpentane is used as a solvent in spectrophotometric analysis and in organic synthesis. Due to its high antiknock octane number, it is widely employed as a standard reference fuel for octane ratings. It acts as an entrainer in azeotropic distillation as well as thinner. It is involved
Formule :C8H18Degré de pureté :99%Couleur et forme :Liquid, Clear colorlessMasse moléculaire :114.232,2,4-Trimethylpentane, HPLC grade
CAS :2,2,4-Trimethylpentane, HPLC gradeMasse moléculaire :114.231g/mol2,2,4-Trimethylpentane, glass distilled
CAS :2,2,4-Trimethylpentane, glass distilledMasse moléculaire :114.231g/molReagecon Density Standard Premium Range 0.7073 g/mL at 15°C
CAS :This Reagecon Density Standard Premium Range 0.7073 g/mL at 15°C is manufactured and tested in accordance with ASTM D1480-12 for testing of density or relative density (specific and API gravity). It is tested by Bingham Pycnometry and can be used as a calibration or control standard for density measurement by pycnometer, vibrational, or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using Bingham Pycnometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 Accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). The density of the product is established and tested using high performance calibrated reference pycnometers. - High accuracy (± 0.00077 g/ml) - Tested using a fundamental measurement technique (Bingham Pycnometer)Couleur et forme :LiquidReagecon Density Standard Quality Range 0.7337 g/mL at 25°C
CAS :This Reagecon Density Standard Quality Range 0.7337 g/mL at 25°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%Couleur et forme :LiquidReagecon Density Standard Premium Range 0.6997 g/mL at 40°C
CAS :This Reagecon Density Standard Premium Range 0.6997 g/mL at 40°C is manufactured and tested in accordance with ASTM D1480-12 for testing of density or relative density (specific and API gravity). It is tested by Bingham Pycnometry and can be used as a calibration or control standard for density measurement by pycnometer, vibrational, or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using Bingham Pycnometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 Accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). The density of the product is established and tested using high performance calibrated reference pycnometers. - High accuracy (± 0.00077 g/ml) - Tested using a fundamental measurement technique (Bingham Pycnometer)Couleur et forme :LiquidReagecon Density Standard Premium Range 0.7033 g/mL at 20°C
CAS :This Reagecon Density Standard Premium Range 0.7033 g/mL at 20°C is manufactured and tested in accordance with ASTM D1480-12 for testing of density or relative density (specific and API gravity). It is tested by Bingham Pycnometry and can be used as a calibration or control standard for density measurement by pycnometer, vibrational, or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using Bingham Pycnometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 Accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). The density of the product is established and tested using high performance calibrated reference pycnometers. - High accuracy (± 0.00077 g/ml) - Tested using a fundamental measurement technique (Bingham Pycnometer)Couleur et forme :LiquidReagecon Density Standard Premium Range 0.7148 g/mL at 20°C
CAS :This Reagecon Density Standard Premium Range 0.7148 g/mL at 20°C is manufactured and tested in accordance with ASTM D1480-12 for testing of density or relative density (specific and API gravity). It is tested by Bingham Pycnometry and can be used as a calibration or control standard for density measurement by pycnometer, vibrational, or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using Bingham Pycnometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 Accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). The density of the product is established and tested using high performance calibrated reference pycnometers. - High accuracy (± 0.00077 g/ml) - Tested using a fundamental measurement technique (Bingham Pycnometer)Couleur et forme :LiquidReagecon Density Standard Quality Range 0.7033 g/mL at 20°C
CAS :This Reagecon Density Standard Quality Range 0.7033 g/mL at 20°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%Couleur et forme :LiquidReagecon Density Standard Quality Range 0.7374 g/mL at 20°C
CAS :This Reagecon Density Standard Quality Range 0.7374 g/mL at 20°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%Couleur et forme :LiquidReagecon Density Standard Quality Range 0.6997 g/mL at 40°C
CAS :This Reagecon Density Standard Quality Range 0.6997 g/mL at 40°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%Couleur et forme :Liquid



