
Physicochemical Standards
Physicochemical standards are essential reference materials used to ensure the accuracy and reliability of various analytical measurements in scientific research and industrial applications. This category includes a wide range of standards such as conductivity standards, electrochemistry standards, and ICP-OES/ICP-MS standards and reagents, which are critical for precise elemental analysis and conductivity measurements. pH buffer solutions and total organic/inorganic carbon reagents are vital for maintaining pH levels and measuring carbon content in samples. Standards from European Pharmacopoeia (EP), United States Pharmacopoeia (USP), and other pharmacopoeias provide benchmarks for pharmaceutical quality control. Additional standards like turbidity, density, refractometry, and viscosity standards ensure accurate physical property measurements. Specialized standards, such as those for wine, dairy, and petrochemical industries, support quality control and regulatory compliance in specific sectors. These physicochemical standards play a crucial role in ensuring the validity and reproducibility of experimental results, supporting a wide range of applications from environmental monitoring to pharmaceutical testing and materials science.
Subcategories of "Physicochemical Standards"
- Colour Standards(74 products)
- Cryoscope Standards(10 products)
- Density Standards(107 products)
- Melting Point Standards(16 products)
- Osmolality Standards(27 products)
- Refractive Index Standards(96 products)
- Turbidity Standards(137 products)
- Viscosity Standards(75 products)
Found 3970 products of "Physicochemical Standards"
Sort by
The purity filter is not visible because current products do not have associated purity data for filtering.
Reagecon Sodium Lauryl Sulphate 0.50% Dissolution Media in accordance to United States Pharmacopoeia (USP)
Reagecon's Sodium Lauryl Sulphate 0.50% Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon 30,000 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 3M Potassium Chloride Electrode Filling Solution (Electrolyte) Free from Silver Ion
Concentrated or saturated Potassium Chloride (KCl) is the optimal electrolyte and filling solution for potentiometric titrations, direct pH measurement, redox or ion measurement where silver/silver chloride or calomel reference electrodes are used. However, saturated KCl is only sparingly soluble below 20°C, so if measurements below this temperature are to be carried out 3M Potassium Chloride remains in solution down to less than 10°C. - A good electrolyte must fulfil a number of conditions. The equitransference of the cation/anion combination should be as close as possible to being equimobile, have constant chloride activity, be of high electrical conductance and be as non-chemically reactive as possible. Reagecon 3M Potassium Chloride Electrode Filling Solution is a high quality product that fulfils all of these criteria.Color and Shape:LiquidReagecon Di Sodium Phosphate 55.3g and Citric Acid 4.8g Adjust to pH 6.8 Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP)
Reagecon's Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon 12,880 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon pH 4.00 Colour Coded Buffer Solution at 20°C
Reagecon's pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Hydrochloric Acid 6M according to European Pharmacopoeia (EP) Chapter 4 (4.2.2)
Reagecon's Hydrochloric Acid 6M is a fully factorised, high purity, stable product, developed and tested for titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.2%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties as detailed in several EP monographs. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stochiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon 84 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 1000 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon pH 7.40 Phosphate Buffer Saline Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.3)
Reagecon’s pH 7.4 Phosphate Buffer Saline Solution is specified for use in individual European Pharmacopoeia (EP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable; has guaranteed stability throughout its entire shelf life; even after opening the bottle. - NIST traceableColor and Shape:LiquidReagecon 10,000 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon pH 3.50 Buffer Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.3)
Reagecon’s pH 3.5 Buffer Solution is specified for use in individual European Pharmacopoeia (EP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable; has guaranteed stability throughout its entire shelf life; even after opening the bottle. - NIST traceableColor and Shape:LiquidReagecon Hydrochloric Acid 0.1N Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP)
Reagecon's Hydrochloric Acid 0.1N Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon 20 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 500 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon Platinum-Cobalt (Hazen) 500 Colour Standard
Reagecon's Platinum-Cobalt (Hazen) 500 Colour Standard can be used to calibrate, control, qualify or validate colour measurement instruments. This standard can be described as Platinum-Cobalt, Pt-Co, Hazen or APHA colour. All descriptions are interchangeable. This product is used extensively in the water industry and several other industries. The standard covers the requirements of ASTM Method D 1209.Color and Shape:LiquidReagecon Sodium Standard for ICP, ICP-MS 10,000 µg/mL (10,000 ppm) in 3.5% Nitric Acid (HNO₃)
Reagecon's Sodium Standard for ICP; ICP-MS 10;000 µg/mL (10;000 ppm) in 3.5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 10.00 Colour Coded Buffer Solution at 20°C
Reagecon's pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 8.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 10.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Carbonate pH 9.00 Borax Free Buffer Solution at 20°C
Reagecon’s Borax Free pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Carbonate pH 10.00 Borax Free Buffer Solution at 25°C
Reagecon’s Borax Free pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Carbonate pH 10.00 Borax Free Buffer Solution at 20°C
Reagecon’s Borax Free pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Vapour Pressure Calibration Standard (2 Compound Mix), D5191
This Reagecon Vapour Pressure Calibration Standard 2 Compound Mix is a ready to use standard used as either a calibrant or as an analytical quality control material for standard test methods for vapour pressure measurement of petroleum products and liquid fuels. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - This standard is used in in accordance with the International Standard ASTM D5191 using infrared (IR) instrumentation. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. Description | Concentration: - N-Petane: 68.5 %. - Toulene: 31.5 %.Color and Shape:LiquidReagecon Gasoline Calibration Standard (4 Compound Mix) in Petroleum Ether
This Reagecon Gasoline Calibration Standard (4 Compound Mix) in Petroleum Ether is a ready to use standard used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing for a range of Aromatic and Oxygenate compounds in Gasoline in accordance with the ASTM D5845, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS. Description | Concentration: - Naphtalin: 3 %. - o-xylene: 6.2%. - p-xylene: 6 %. - MTBE: 10.6 %.Color and Shape:LiquidReagecon Volatile Organic Compound (VOC) Single Compound Standard Chlorophyll a 20 µg/mL in Acetone
This Reagecon Volatile Organic Compound (VOC) Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Pesticide Single Compound Standard 2,4-D 13C6 100ug/ml in Acetone
This Reagecon Pesticide Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Azo Dye Metabolite Single Compound Standard Aniline 1000 µg/mL in Purge and Trap Methanol
This Reagecon Azo Dye Single Metabolite Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library.Color and Shape:LiquidReagecon Pesticide Single Compound Standard 2,4-D 13C6 100 µg/mL in Acetonitrile
This Reagecon Pesticide Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Pesticide Standard (2 Compound Mix) in Methanol
This Reagecon Pesticide Standard 2 Compound Mix is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested. Description | Concentration: - Methyl Mercury Chloride: 1000 µg/mL. - Ethyl Mercury Chloride: 1000 µg/mL.Color and Shape:LiquidReagecon Vapour Pressure Calibration Standard (2 Compound Mix), D5191
This Reagecon Vapour Pressure Calibration Standard 2 Compound Mix is a ready to use standard used as either a calibrant or as an analytical quality control material for standard test methods for vapour pressure measurement of petroleum products and liquid fuels. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - This standard is used in in accordance with the International Standard ASTM D5191 using infrared (IR) instrumentation. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. Description | Concentration: - N-Petane: 22 %. - Toulene: 78 %.Color and Shape:LiquidReagecon Volatile Organic Compound (VOC) Single Compound Standard Pyridine 2000 µg/mL in Purge & Trap Methanol
This Reagecon Volatile Organic Compound (VOC) Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Pesticide Single Compound Internal Standard Decafluorobiphenyl 1000 µg/mL in Acetonitrile
This Reagecon Pesticide Single Compound Internal Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Pesticide Single Compound Standard Acetochlor-d11 100 µg/mL in Acetone
This Reagecon Pesticide Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Volatile Organic Compound (VOC) Single Compound Standard Nitrobenzene-d5 1000 µg/mL in Methanol
This Reagecon Volatile Organic Compound (VOC) Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Gasoline Calibration Standard (3 Compound Mix) in Petroleum Ether
CAS:This Reagecon Gasoline Calibration Standard (3 Compound Mix) in Petroleum Ether is a ready to use standard used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing for a range of Aromatic and Oxygenate compounds in Gasoline in accordance with the ASTM D5845, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS. Description | Concentration: - ETBE: 20 %. - Methanol: 6 %. - Petroleum Ether: 54 %. - TAME: 20 %.Color and Shape:LiquidReagecon Volatile Organic Compound (VOC) Single Compound Standard Benzidine-d8 200 µg/mL in Methanol
This Reagecon Volatile Organic Compound (VOC) Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Gasoline Calibration Standard (2 Compound Mix) in Petroleum Ether
CAS:This Reagecon Gasoline Calibration Standard (2 Compound Mix) in Petroleum Ether is a ready to use standard used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing Benzene levels in Gasoline in accordance with the International Standard ASTM D6277 and EN 238, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS. Description | Concentration: - Benzene: 0.5 %. - Toluene: 15 %.Color and Shape:LiquidReagecon Pesticide Standard (8 Compound Mix) in Hexane:Acetone
CAS:This Reagecon Pesticide Standard 8 Compound Mix is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested. Description | Concentration: - 2,4'-DDT: 100 µg/mL. - 4,4'-DDD: 100 µg/mL. - 4,4'-DDE: 100 µg/mL. - 4,4'-DDT: 100 µg/mL. - alpha-BHC: 100 µg/mL. - beta-BHC: 100 µg/mL. - delta-BHC: 100 µg/mL. - lindane: 100 µg/mL.Color and Shape:LiquidReagecon Gasoline Calibration Standard (2 Compound Mix) in Petroleum Ether
This Reagecon Gasoline Calibration Standard (2 Compound Mix) in Petroleum Ether is a ready to use standard used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing Benzene levels in Gasoline in accordance with the International Standard ASTM D6277 and EN 238, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS. Description | Concentration: - Benzene: 3.5%. - Mesitylen: 11.5 %.Color and Shape:LiquidReagecon Ion Chromatography (IC) Multi Element Anion Standard (7 Elements) in Water (H₂O)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 9.00 Buffer Solution at 25°C in Twin Neck
Reagecon's pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (7 Elements) in 10% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon's Multi Element Standard for ICP; ICP-MS in 10% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Calcium (Ca): 200 µg/mL (ppm). - Iron (Fe): 5 µg/mL (ppm). - Magnesium (Mg): 100 µg/mL (ppm). - Phosphorus (P): 200 µg/mL (ppm). - Potassium (K): 500 µg/mL (ppm). - Sodium (Na): 200 µg/mL (ppm). - Zinc (Zn): 5 µg/mL (ppm).Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (5 Elements) in 5% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 5% HNO₃ is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Calcium (Ca): 2000 µg/mL (ppm). - Iron (Fe): 2000 µg/mL (ppm). - Potassium (K): 2000 µg/mL (ppm). - Magnesium (Mg): 2000 µg/mL (ppm). - Sodium (Na): 2000 µg/mL (ppm).Color and Shape:LiquidReagecon Antimony Standard for Atomic Absorption (AAS) 10,000 µg/mL (10,000 ppm) in Water (H₂O)
Reagecon's Antimony Standard for Atomic Absorption (AAS) 10;000 µg/mL in Water (H₂O) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 8.00 Buffer Solution at 20°C in Bag-in-Box
Reagecon's pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Refractive Index Standard (Stabilised Sucrose) 1.35171 nD units at 20°C
Reagecon's Refractive Index Standard (Stabilised Sucrose) 1.35171 nD units at 20°C is a high quality product, with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Refractive Index determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer, manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation for the test method used to certify this product. - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.00014 nD units. It is stable for one year; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.00014 nD units) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon System Suitability Set to USP for Total Organic (TOC) suitable for use with Sievers 900/M9 Analysers
Reagecon's System Suitability Set to USP for Total Organic (TOC) is a product of extremely high specification and purity. The product is produced from ultra pure raw materials including water that is prepared by a special proprietary process. The product is presented in vials that are manufactured, cleaned and leached, by a special proprietary process specifically for the product. - The products RTOCRs and RTOCRss from the table above are prepared gravimetrically on a weight/volume basis to a specification of ± 2%. Reagecon holds IEC/ISO 17025 accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). Products are tested using a high performance calibrated Total Organic Carbon Analyser (TOC Instrument); RTOCRs and RTOCRss are tested within the scope of Reagecon’s ISO 17025 accredited test method (A2LA Ref: 6739.03) and RTOCW is not tested within the scope of the accredited test method. Item No - Description | Qty: - RTOCRs-TOC Standard USP Standard Sucrose Solution Rs (0.5mg/L C): 1. - RTOCRss-TOC Standard USP System Suitability Solution 1 4-Benzoquinone (0.5mg/L C): 1. - RTOCW-TOC Standard USP Reagent Water Rw: 1.Color and Shape:Liquid

