Physicochemical Standards
Physicochemical standards are essential reference materials used to ensure the accuracy and reliability of various analytical measurements in scientific research and industrial applications. This category includes a wide range of standards such as conductivity standards, electrochemistry standards, and ICP-OES/ICP-MS standards and reagents, which are critical for precise elemental analysis and conductivity measurements. pH buffer solutions and total organic/inorganic carbon reagents are vital for maintaining pH levels and measuring carbon content in samples. Standards from European Pharmacopoeia (EP), United States Pharmacopoeia (USP), and other pharmacopoeias provide benchmarks for pharmaceutical quality control. Additional standards like turbidity, density, refractometry, and viscosity standards ensure accurate physical property measurements. Specialized standards, such as those for wine, dairy, and petrochemical industries, support quality control and regulatory compliance in specific sectors. These physicochemical standards play a crucial role in ensuring the validity and reproducibility of experimental results, supporting a wide range of applications from environmental monitoring to pharmaceutical testing and materials science.
Subcategories of "Physicochemical Standards"
- Colour Standards(74 products)
- Cryoscope Standards(10 products)
- Density Standards(107 products)
- Melting Point Standards(16 products)
- Osmolality Standards(27 products)
- Refractive Index Standards(96 products)
- Turbidity Standards(137 products)
- Viscosity Standards(75 products)
Found 3970 products of "Physicochemical Standards"
Sort by
The purity filter is not visible because current products do not have associated purity data for filtering.
Reagecon 200 mV Redox Oxidation/Reduction (ORP) Standard at 25°C
This Reagecon's 200 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 200 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.Color and Shape:LiquidReagecon Hydrochloric Acid 0.2M (0.2N) Analytical Volumetric Solution (AVL)
Reagecon's Hydrochloric Acid 0.2M (0.2N) Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Perchloric Acid 0.1M (0.1N) in Acetic Acid Analytical Volumetric Solution (AVL)
Reagecon's Perchloric Acid 0.1M (0.1N) in Acetic Acid Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Polycyclic Aromatic Hydrocarbon (PAH) Standard (5 Compound Mix) in Hexane: Acetone
CAS:This Reagecon Polycyclic Aromatic Hydrocarbon (PAH) Standard 5 Compound Mix is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC, GC-MS, HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested. Description | Concentration: - acenaphthene-d10: 1000 µg/mL. - phenanthrene-d10: 1000 µg/mL. - chrysene-d12: 1000 µg/mL. - perylene-d12: 1000 µg/mL. - naphthalene-d8: 1000 µg/mL.Color and Shape:LiquidReagecon Volatile Organic Compound (VOC) Single Compound Standard Acrolein 1000 µg/mL in Water
This Reagecon Volatile Organic Compound (VOC) Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Stock Solution to make Arsenic Trioxide according to United States Pharmacopoeia (USP)
Reagecon's Stock Solution to make Arsenic Trioxide according to United States Pharmacopoeia (USP) is specified for use in individual United States Pharmacopoeia (USP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03); is NIST traceable and has guaranteed stability throughout its entire shelf life; even after opening the bottle.Color and Shape:LiquidReagecon Germanium Standard for Atomic Absorption (AAS) 1000 µg/mL (1000 ppm) in 1% Hydroflouric Acid (HF), 5% Nitric Acid (HNO₃)
Reagecon's Germanium Standard for Atomic Absorption (AAS) 1000 µg/mL in 1% Hydroflouric Acid (HF); 5% Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Iron Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)
Reagecon's Iron Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Total Acid Number (TAN) Standard 1.5 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix
Reagecon Total Acid Number (TAN) Standard 1.5 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This high quality standard can be used to calibrate; control or validate the methodology or equipment used to perform TAN testing according to ASTM Method D664. - Produced in accordance with ASTM D664. - The TAN test method D664 is used to indicate relative changes that occur in oil during use under oxidising conditions regardless of the colour or other properties of the oil. - The test method D664 is also used as a guide in quality control of lubricating oil formulations or as a measure of lubricant degradation. - Standards are traceable to NIST. - The method has a very low uncertainty of measurement which is linked to the TAN value and is expressed as a percentage of that value. - Stability is proven (either opened or unopened) for the shelf life of this product. - This Standard forms part of the linearity set of TAN Standards that range in value from 0.5 mg/g KOH in a synthetic base oil up to 4.5 mg/g KOH. - Consistency of product - Independent; Traceable; Certified.Color and Shape:SolidReagecon Potassium Phosphate pH 7.4 Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP) Concentrate
Reagecon's Potassium Phosphate pH 7.4 Dissolution Media Concentrate is presented in concentrate form. This concentrate measures 384ml in volume in each bottle and the contents of each bottle can be diluted to produce 10L of working solution in water. This diluted volume is the working Dissolution Medium. The product is prepared and when diluted can be used in accordance with relevant pharmacopoeia requirements. - This product is presented as a concentrate in order to facilitate easy shipping, storage and handling. - The pack contains 12 bottles, each of which has a volume of 384ml of solution, each 384ml bottle is diluted to give 10L of ready to use Dissolution Medium.Color and Shape:LiquidReagecon Eribium Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)
Reagecon's Eribium Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Density Standard Premium Range 0.6997 g/mL at 40°C
CAS:This Reagecon Density Standard Premium Range 0.6997 g/mL at 40°C is manufactured and tested in accordance with ASTM D1480-12 for testing of density or relative density (specific and API gravity). It is tested by Bingham Pycnometry and can be used as a calibration or control standard for density measurement by pycnometer, vibrational, or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using Bingham Pycnometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 Accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). The density of the product is established and tested using high performance calibrated reference pycnometers. - High accuracy (± 0.00077 g/ml) - Tested using a fundamental measurement technique (Bingham Pycnometer)Color and Shape:LiquidReagecon pH 9.18 Buffer Solution at 25°C according to European Pharmacopoeia (EP)
Reagecon's pH Buffer Solution at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable; has guaranteed stability throughout its entire shelf life; even after opening the bottle. The product is developed; formulated and specified in accordance with EP requirements. - NIST traceableColor and Shape:LiquidReagecon Acetic Acid Ammonium Acetate Buffer TS Solution according to United States Pharmacopoeia (USP)
Reagecon's Acetic Acid Ammonium Acetate Buffer TS Solution according to United States Pharmacopoeia (USP) is specified for use in individual United States Pharmacopoeia (USP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03); is NIST traceable and has guaranteed stability throughout its entire shelf life; even after opening the bottle.Color and Shape:LiquidReagecon Cobalt Standard for Atomic Absorption (AAS) 1000 µg/mL (1000 ppm) in 0.5M Nitric Acid (HNO₃)
CAS:Reagecon's Cobalt Standard for Atomic Absorption (AAS) 1000 µg/mL in 0.5M Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Phenolphthalein R1 Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Phenolphthalein R1 Solution is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include use as an indicator In volumetric titrations, plus as an indicator of pH change as outlined in several EP monographs. - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon pH 9.40 Buffer Solution at 25°C
Reagecon’s pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Fluoride 100ppm Ion Selective Electrode Standard
Reagecon's Fluoride 100ppm Ion Selective Electrode Standard can be used at suitable concentrations to calibrate or control measurements that use Ion Selective Electrodes (ISE’s) as the sensing technology. - Reagecon’s Ion Selective Electrode (ISE) Standards; diluted to a suitable concentration; are particularly suitable for use as a calibration or control material; using Ion Selective Electrodes as the sensing technology. - Accurate to ± 0.5%. - Aqueous matrix. - Directly traceable to NIST standard reference materials. - Can be used for Method Validation or Instrument Qualification. - Can also be used as a calibrant for other techniques. - Safe; compatible with all types of ISE Electrodes. - Manufactured to exacting specifications with an extended shelf life & stability; even after opening the bottle.Color and Shape:Liquid