Reagecon Volatile Organic Compound (VOC) Single Compound Standard Benzidine-d8 200 µg/mL in Methanol
This Reagecon Volatile Organic Compound (VOC) Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Gasoline Calibration Standard (2 Compound Mix) in Petroleum Ether
CAS:This Reagecon Gasoline Calibration Standard (2 Compound Mix) in Petroleum Ether is a ready to use standard used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing for a range of Aromatic and Oxygenate compounds in Gasoline in accordance with the ASTM D5845, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS. Description | Concentration: - Ethanol: 11 %. - MTBE: 20 %. - Petroluem Ether: 69 %.Color and Shape:LiquidReagecon Pesticide Standard (8 Compound Mix) in Hexane:Acetone
This Reagecon Pesticide Standard 8 Compound Mix is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested. Description | Concentration: - alpha-BHC: 400 µg/mL. - beta-BHC: 1000 µg/mL. - Lindane: 600 µg/mL. - delta-BHC: 600 µg/mL. - 4,4'-DDT: 1500 µg/mL. - 2,4'-DDT: 1000 µg/mL. - 4,4'-DDE: 800 µg/mL. - 4,4'-DDD: 1000 µg/mL.Color and Shape:LiquidReagecon Gasoline Calibration Standard (2 Compound Mix) in Petroleum Ether
CAS:This Reagecon Gasoline Calibration Standard (2 Compound Mix) in Petroleum Ether is a ready to use standard used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing Benzene levels in Gasoline in accordance with the International Standard ASTM D6277 and EN 238, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS. Description | Concentration: - Benzene: 0.5 %. - Toluene: 15 %.Color and Shape:LiquidReagecon Polychlorinated Biphenyl (PCB) Deuterated Internal Standard (2 Compound Mix) in Hexane
This Reagecon PCB Multi Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. Description | Concentration: - PCB77-d6: 10 µg/mL. - PCB156-d3: 10 µg/mL.Color and Shape:LiquidReagecon Polycyclic Aromatic Hydrocarbon (PAH) Internal Standard (6 Compound Mix) in Dichloromethane
This Reagecon Polycyclic Aromatic Hydrocarbon (PAH) Internal Standard 6 Compound Mix is a ready to use group of compounds that are added to samples and calibration standards at a known concentration; in order to provide a basis for comparison in quantification. This product is particularly suitable for calculating the response factor. - The product is used for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. It can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested. Description | Concentration: - acenaphthene-d10: 2000 µg/mL. - phenanthrene-d10: 2000 µg/mL. - chrysene-d12: 2000 µg/mL. - perylene-d12: 2000 µg/mL. - naphthalene-d8: 2000 µg/mL. - 1,4-Dichlorobenzene-d4: 2000 µg/mL.Color and Shape:LiquidReagecon Pesticide Standard (8 Compound Mix) in Hexane:Acetone
CAS:This Reagecon Pesticide Standard 8 Compound Mix is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested. Description | Concentration: - 2,4'-DDT: 100 µg/mL. - 4,4'-DDD: 100 µg/mL. - 4,4'-DDE: 100 µg/mL. - 4,4'-DDT: 100 µg/mL. - alpha-BHC: 100 µg/mL. - beta-BHC: 100 µg/mL. - delta-BHC: 100 µg/mL. - lindane: 100 µg/mL.Color and Shape:LiquidReagecon Fatty Acid Methyl Ester (FAME) 8 Compound Mix Method A Reference Solution in n-Heptane according to European Pharmacopoeia (EP) Chapter 2.4.22, Table 3
CAS:This Reagecon Fatty Acid Methyl Ester (FAME) 8 Compound Mix is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - The esterification of fatty acids is an important tool for both characterising fats and oils and for determining the total fat content in foods and foodstuffs. It is also an important measurement for the assessing of quality and purity of biofuels. Description | Concentration: - Methyl Myristate: 10% w/w. - Methyl Palmitate: 15% w/w. - Methyl Stearate: 20% w/w. - Methyl Arachidate: 20% w/w. - Methyl Oleate: 10% w/w. - Methyl Eicosenoate: 5% w/w. - Methyl Behenate: 10% w/w. - Methyl Linocerate: 10% w/w.Color and Shape:LiquidReagecon Pesticide Internal Standard (4 Compound Mix) in Methanol, acc Water Test HJ827
This Reagecon Pesticide Internal Standard 4 Compound Mix is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested. Description | Concentration: - Carbaryl-d7: 20 µg/mL. - Carbofuran-d3: 20 µg/mL. - Methiocarb-d3: 5 µg/mL. - Methomyl-d3: 20 µg/mL.Color and Shape:LiquidReagecon Volatile Organic Compound (VOC) Single Compound Standard Tetraethyl Lead 200 µg/mL in Purge and Trap Methanol
This Reagecon Volatile Organic Compound (VOC) Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Volatile Organic Compound (VOC) Standard (3 Compound Mix) in Methanol
This Reagecon Volatile Organic Compound (VOC) Standard 3 Compound Mix is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested. Description | Concentration: - 4-bromofluorobenzene (BFB): 2000 µg/mL. - dibromofluoromethane: 2000 µg/mL. - toluene-d8: 2000 µg/mL.Color and Shape:LiquidReagecon Volatile Organic Compound (VOC) Single Compound Standard 4-Bromofluorobenzene 2000 µg/mL in Methanol
This Reagecon Volatile Organic Compound (VOC) Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon PBDE Multi Compound Standard (8 Compounds) in Hexane:Toluene
CAS:This Reagecon PBDE Multi Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. Description | Concentration: - 2,4,4'-Tribromodiphenyl ether: 20 µg/mL. - 2,2',4,4'-Tetrabromodiphenyl ether: 20 µg/mL. - 2,2',4,4',5-Pentabromodiphenyl ether: 20 µg/mL. - 2,2',4,4',6-Pentabromodiphenyl ether: 20 µg/mL. - 2,2',4,4',5,5'-Hexabromodiphenyl ether: 20 µg/mL. - 2,2',4,4',5,6'-Hexabromodiphenyl ether: 20 µg/mL. - 2,2',3,4,4',5',6-Heptabromodiphenyl ether: 20 µg/mL. - 2,2',3,3',4,4',5,5',6,6'-Decabromodiphenyl ether: 200 µg/mL.Color and Shape:LiquidReagecon Smoke Point Kit ASTM D1322, Standard Smoke Point Blends at 101.3 kPa
This Reagecon Smoke Point Kit is used in fuel analysis for the calibration of or as an analytical quality control material for the measurement of smoke point in petrochemical products. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS.Color and Shape:LiquidReagecon Cetane Improver 2-Ethylhexyl Nitrate 0.2% Calibration Standard in Chevron Phillips High Cetane Reference Fuel
This Reagecon Cetane Improver Calibration Standard is a ready to use standard in Petroleum Ether used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing for 2-Ethylhexyl Nitrate a known Cetane improver, in Diesel, in accordance with the International Standard ASTM E1655, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS.Color and Shape:LiquidReagecon Sodium Sulphide Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Sodium Sulphide Solution is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include the preparation of other reagents (4.1.1), use in identification reactions of ions and functional groups (2.3.1) and used as a reagent in the performance of tests outlined in several EP monographs.
- NIST traceable
- This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (29 Elements) in 2-5% Nitric Acid (HNO₃) and trace Hydrofluoric Acid (HF)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation.
Reagecon's Multi Element Standard for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) and trace Hydrofluoric Acid (HF) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances.
- GHS/OSHA compliant, REACH
- This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.
Description | Concentration:
- Aluminium (Al): 100 µg/mL (ppm).
- Antimony (Sb): 100 µg/mL (ppm).
- Arsenic (As): 100 µg/mL (ppm).
- Barium (Ba): 100 µg/mL (ppm).
- Bismuth (Bi): 100 µg/mL (ppm).
- Boron (B): 100 µg/mL (ppm).
- Cadmium (Cd): 100 µg/mL (ppm).
- Calcium (Ca): 100 µg/mL (ppm).
- Chromium (Cr): 100 µg/mL (ppm).
- Cobalt (Co): 100 µg/mL (ppm).
- Copper (Cu): 100 µg/mL (ppm).
- Gallium (Ga): 100 µg/mL (ppm).
- Hafnium (Hf): 100 µg/mL (ppm).
- Indium (In): 100 µg/mL (ppm).
- Iron (Fe): 100 µg/mL (ppm).
- Lead (Pb): 100 µg/mL (ppm).
- Lithium (Li): 100 µg/mL (ppm).
- Magnesium (Mg): 100 µg/mL (ppm).
- Manganese (Mn): 100 µg/mL (ppm).
- Molybdenum (Mo): 100 µg/mL (ppm).
- Nickel (Ni): 100 µg/mL (ppm).
- Potassium (K): 100 µg/mL (ppm).
- Silver (Ag): 100 µg/mL (ppm).
- Sodium (Na): 100 µg/mL (ppm).
- Strontium (Sr): 100 µg/mL (ppm).
- Thallium (Tl): 100 µg/mL (ppm).
- Titanium (Ti): 100 µg/mL (ppm).
- Tungsten (W): 100 µg/mL (ppm).
- Zinc (Zn): 100 µg/mL (ppm).Color and Shape:LiquidReagecon Zirconium Standard for ICP, ICP-MS 100 µg/mL (100 ppm) in 1% Hydrofluoric Acid (HF) and 5% Nitric Acid (HNO₃)
Reagecon's Zirconium Standard for ICP; ICP-MS 100 µg/mL (100 ppm) in 1% Hydrofluoric Acid (HF) and 5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances.
- GHS/OSHA compliant, REACH
- This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 6.86 at 25°C Equimolal Phosphate 0.05M according to United States Pharmacopoeia (USP)
Reagecon's pH 6.86 at 25°C Equimolal Phosphate 0.05M according to United States Pharmacopoeia (USP) is specified for use in individual United States Pharmacopoeia (USP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03); is NIST traceable and has guaranteed stability throughout its entire shelf life; even after opening the bottle.
Color and Shape:Liquid