Physicochemical standards are essential reference materials used to ensure the accuracy and reliability of various analytical measurements in scientific research and industrial applications. This category includes a wide range of standards such as conductivity standards, electrochemistry standards, and ICP-OES/ICP-MS standards and reagents, which are critical for precise elemental analysis and conductivity measurements. pH buffer solutions and total organic/inorganic carbon reagents are vital for maintaining pH levels and measuring carbon content in samples. Standards from European Pharmacopoeia (EP), United States Pharmacopoeia (USP), and other pharmacopoeias provide benchmarks for pharmaceutical quality control. Additional standards like turbidity, density, refractometry, and viscosity standards ensure accurate physical property measurements. Specialized standards, such as those for wine, dairy, and petrochemical industries, support quality control and regulatory compliance in specific sectors. These physicochemical standards play a crucial role in ensuring the validity and reproducibility of experimental results, supporting a wide range of applications from environmental monitoring to pharmaceutical testing and materials science.
Subcategories of "Physicochemical Standards"
- Colour Standards(74 products)
- Cryoscope Standards(10 products)
- Density Standards(107 products)
- Melting Point Standards(16 products)
- Osmolality Standards(27 products)
- Refractive Index Standards(96 products)
- Turbidity Standards(137 products)
- Viscosity Standards(75 products)
Found 3970 products of "Physicochemical Standards"
Sort by
The purity filter is not visible because current products do not have associated purity data for filtering.
Reagecon 30,000 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 200 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 5000 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 1413 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 3M Potassium Chloride Electrode Filling Solution (Electrolyte) Free from Silver Ion
Concentrated or saturated Potassium Chloride (KCl) is the optimal electrolyte and filling solution for potentiometric titrations, direct pH measurement, redox or ion measurement where silver/silver chloride or calomel reference electrodes are used. However, saturated KCl is only sparingly soluble below 20°C, so if measurements below this temperature are to be carried out 3M Potassium Chloride remains in solution down to less than 10°C. - A good electrolyte must fulfil a number of conditions. The equitransference of the cation/anion combination should be as close as possible to being equimobile, have constant chloride activity, be of high electrical conductance and be as non-chemically reactive as possible. Reagecon 3M Potassium Chloride Electrode Filling Solution is a high quality product that fulfils all of these criteria.Color and Shape:LiquidReagecon Di Sodium Phosphate 55.3g and Citric Acid 4.8g Adjust to pH 6.8 Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP)
Reagecon's Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon 12,880 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon Ammonium Cerium Nitrate 0.01M according to European Pharmacopoeia (EP) Chapter 4 (4.2.2)
CAS:Controlled ProductReagecon's Ammonium Cerium Nitrate 0.01M is a fully factorised, high purity, stable product, developed and tested for titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.2%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties as detailed in several EP monographs. - NIST traceable - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stochiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon 50,000 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon Opalescence Reference Standard Stock Solution according to Chinese Pharmacopoeia (ChP)
Reagecon's Opalescence Reference Standard Stock Solution is used as a reference material to ascertain the clarity and degree of opalescence of liquids in accordance with Chinese Pharmacopoeia (ChP). - This Primary Opalescence Suspension is a ready to use Standard presented in high quality, tamper evident bottles for use in calibrating Comparators, Turbidimeters and Nephelometers and for controlling the reproducibility of their measurements. This product is a formazin suspension prepared with equal parts hexamethylenetetramine solution and hydrazine sulphate solution. This combination is defined as a 4000 NTU (Nephelometric Turbidity Units) Primary Reference Standard. - Concentration verified using a high performance Spectrophotometer or Nephelometer. - The Primary Opalescence Suspension maybe diluted in precise ratios to form the ChP Reference Opalescence SuspensionsColor and Shape:Liquid SuspensionReagecon 12,880 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 80,000 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon pH 4.00 Colour Coded Buffer Solution at 20°C
Reagecon's pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Hydrochloric Acid 0.01N Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP)
Reagecon's Hydrochloric Acid 0.01N Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon Hydrochloric Acid 6M according to European Pharmacopoeia (EP) Chapter 4 (4.2.2)
Reagecon's Hydrochloric Acid 6M is a fully factorised, high purity, stable product, developed and tested for titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.2%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties as detailed in several EP monographs. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stochiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon 84 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 3000 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon Ion Chromatography (IC) Multi Element Standard (3 Elements) in 1% Nitric Acid (HNO₃)
Reagecon's Ion Chromatography (IC) Multi Element Standard (3 Elements) in 1% HNO₃ is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Magnesium (Mg): 5000 µg/mL (ppm). - Phosphorus (P): 300 µg/mL (ppm). - Potassium (K): 5000 µg/mL (ppm).Color and Shape:LiquidReagecon 1000 NTU Ratio Turbidity Standard
Reagecon 1000 NTU Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon 1000 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon pH 7.00 Colour Coded Buffer Solution at 20°C
Reagecon's pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 3M Potassium Chloride Electrode Filling Solution Saturated with Silver Chloride (Electrolyte)
Concentrated or saturated Potassium Chloride (KCl) is the optimal electrolyte and filling solution for potentiometric titrations, direct pH measurement, redox or ion measurement where silver/silver chloride or calomel reference electrodes are used. However, saturated KCl is only sparingly soluble below 20°C, so if measurements below this temperature are to be carried out 3M Potassium Chloride remains in solution down to less than 10°C. Some electrode manufacturers recommend that the Potassium Chloride be saturated with Silver Chloride (AgCl). - A good electrolyte must fulfil a number of conditions. The equitransference of the cation/anion combination should be as close as possible to being equimobile, have constant chloride activity, be of high electrical conductance and be as non-chemically reactive as possible. Reagecon 3M Potassium Chloride Electrode Filling Solution Saturated with Silver Chloride is a high quality product that fulfils all of these criteria.Color and Shape:LiquidReagecon Sodium Standard for Atomic Absorption (AAS) 1000 µg/mL (1000 ppm) in 0.5M Nitric Acid (HNO₃)
Reagecon's Sodium Standard for Atomic Absorption (AAS) 1000 µg/mL in 0.5M Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 7.40 Phosphate Buffer Saline Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.3)
Reagecon’s pH 7.4 Phosphate Buffer Saline Solution is specified for use in individual European Pharmacopoeia (EP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable; has guaranteed stability throughout its entire shelf life; even after opening the bottle. - NIST traceableColor and Shape:LiquidReagecon 10,000 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon Sulphuric Acid 0.05M (0.1N) Analytical Volumetric Solution (AVL)
Reagecon's Sulphuric Acid 0.05M (0.1N) Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Sodium Lauryl Sulphate 0.50% Dissolution Media in accordance to United States Pharmacopoeia (USP) Concentrate
Reagecon's Sodium Lauryl Sulphate 0.50% Dissolution Media Concentrate is presented in concentrate form. This concentrate measures 1L in volume which can be diluted to produce 20L of working solution in water. This diluted volume is the working Dissolution Medium. The product is prepared and when diluted can be used in accordance with relevant pharmacopoeia requirements. - This product is presented as a concentrate in order to facilitate easy shipping, storage and handling. - The pack contains 1 bottle of which has a volume of 1L of solution, this 1L bottle is diluted to give 20L of ready to use Dissolution Medium.Color and Shape:LiquidReagecon 147 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon Sodium Thiosulphate 0.1M according to European Pharmacopoeia (EP) Chapter 4 (4.2.2)
Reagecon's Sodium Thiosulphate 0.1M is a fully factorised, high purity, stable product, developed and tested for titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.2%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties as detailed in several EP monographs. - NIST traceable - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stochiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Potassium Phosphate pH 7.4 Dissolution Media in accordance to Chinese (CP) United States (USP) and European Pharmacopoeias (EP)
Reagecon's Potassium Phosphate pH 7.4 Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon pH 5.5 Buffer Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.3)
Reagecon’s pH 5.5 Buffer Solution is specified for use in individual European Pharmacopoeia (EP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable; has guaranteed stability throughout its entire shelf life; even after opening the bottle. - NIST traceableColor and Shape:LiquidReagecon Phosphorus Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in Water (H₂O)
Reagecon's Phosphorus Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in Water (H₂O) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon 400 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon Potassium Phosphate pH 7.2 Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP)
Reagecon's Potassium Phosphate pH 7.2 Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon 1413 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon Silicon Standard for ICP, ICP-MS 10,000 µg/mL (10,000 ppm) in Water (H₂O)
Reagecon's Silicon Standard for ICP; ICP-MS 10;000 µg/mL (10;000 ppm) in Water (H₂O) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 3.50 Buffer Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.3)
Reagecon’s pH 3.5 Buffer Solution is specified for use in individual European Pharmacopoeia (EP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable; has guaranteed stability throughout its entire shelf life; even after opening the bottle. - NIST traceableColor and Shape:LiquidReagecon Hydrochloric Acid 0.1N Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP)
Reagecon's Hydrochloric Acid 0.1N Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon 20 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 500 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon Platinum-Cobalt (Hazen) 500 Colour Standard
Reagecon's Platinum-Cobalt (Hazen) 500 Colour Standard can be used to calibrate, control, qualify or validate colour measurement instruments. This standard can be described as Platinum-Cobalt, Pt-Co, Hazen or APHA colour. All descriptions are interchangeable. This product is used extensively in the water industry and several other industries. The standard covers the requirements of ASTM Method D 1209.Color and Shape:LiquidReagecon Sodium Standard for ICP, ICP-MS 10,000 µg/mL (10,000 ppm) in 3.5% Nitric Acid (HNO₃)
Reagecon's Sodium Standard for ICP; ICP-MS 10;000 µg/mL (10;000 ppm) in 3.5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon 300 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon Silver Nitrate 0.01M (0.01N) Analytical Volumetric Solution (AVL)
Reagecon's Silver Nitrate 0.01M (0.01N) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for precipitation (argentometric) titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties. Precipitation titrimetry is based on reactions that yield compounds of limited solubility. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Potassium Phosphate pH 7.5 Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP)
Reagecon's Potassium Phosphate pH 7.5 Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon pH 10.00 Colour Coded Buffer Solution at 20°C
Reagecon's pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 8.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 10.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 7.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Spectrophotometry Stray Light Inorganic 220 nm Cut-off Filter - Sodium Iodide with Blank (ChP)
Reagecon's Spectrophotometry Stray Light Inorganic 220 nm Cut-off Filter - Sodium Iodide (ChP) is formulated to give zero absorbance at 220 nm wavelength. This standard is used to indicate to the analyst that the instrument is measuring light omitted from a source, other than through the sample cuvette.Color and Shape:LiquidReagecon Potassium Dichromate Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Potassium Dichromate Solution is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include use in the identification reactions of ions and functional groups (2.3.1) and used as a reagent in the performance of tests outlined in several EP monographs. - NIST traceable - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon pH 11.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 4.005 DIN 19266 Buffer Solution at 25°C
Reagecon's DIN 19266 pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 13.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 1.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 6.881 NIST Value Buffer Solution at 20°C
Reagecon’s NIST Value pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Carbonate pH 9.00 Borax Free Buffer Solution at 20°C
Reagecon’s Borax Free pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Carbonate pH 10.00 Borax Free Buffer Solution at 25°C
Reagecon’s Borax Free pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Carbonate pH 10.00 Borax Free Buffer Solution at 20°C
Reagecon’s Borax Free pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Vapour Pressure Calibration Standard (2 Compound Mix), D5191
This Reagecon Vapour Pressure Calibration Standard 2 Compound Mix is a ready to use standard used as either a calibrant or as an analytical quality control material for standard test methods for vapour pressure measurement of petroleum products and liquid fuels. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - This standard is used in in accordance with the International Standard ASTM D5191 using infrared (IR) instrumentation. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. Description | Concentration: - N-Petane: 68.5 %. - Toulene: 31.5 %.Color and Shape:LiquidReagecon Gasoline Calibration Standard (4 Compound Mix) in Petroleum Ether
This Reagecon Gasoline Calibration Standard (4 Compound Mix) in Petroleum Ether is a ready to use standard used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing for a range of Aromatic and Oxygenate compounds in Gasoline in accordance with the ASTM D5845, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS. Description | Concentration: - Naphtalin: 3 %. - o-xylene: 6.2%. - p-xylene: 6 %. - MTBE: 10.6 %.Color and Shape:LiquidReagecon Volatile Organic Compound (VOC) Single Compound Standard Chlorophyll a 20 µg/mL in Acetone
This Reagecon Volatile Organic Compound (VOC) Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Pesticide Single Compound Standard 2,4-D 13C6 100ug/ml in Acetone
This Reagecon Pesticide Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Gasoline Calibration Standard (2 Compound Mix) in Petroleum Ether
CAS:This Reagecon Gasoline Calibration Standard (2 Compound Mix) in Petroleum Ether is a ready to use standard used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing for a range of Aromatic and Oxygenate compounds in Gasoline in accordance with the ASTM D5845, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS. Description | Concentration: - DIPE: 20 %. - Petroluem Ether: 66 %. - Tert-Butanol: 14 %.Color and Shape:LiquidReagecon Pesticide Single Compound Standard 2,4-D 13C6 100 µg/mL in Acetonitrile
This Reagecon Pesticide Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Pesticide Standard (2 Compound Mix) in Methanol
This Reagecon Pesticide Standard 2 Compound Mix is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested. Description | Concentration: - Methyl Mercury Chloride: 1000 µg/mL. - Ethyl Mercury Chloride: 1000 µg/mL.Color and Shape:LiquidReagecon Vapour Pressure Calibration Standard (2 Compound Mix), D5191
This Reagecon Vapour Pressure Calibration Standard 2 Compound Mix is a ready to use standard used as either a calibrant or as an analytical quality control material for standard test methods for vapour pressure measurement of petroleum products and liquid fuels. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - This standard is used in in accordance with the International Standard ASTM D5191 using infrared (IR) instrumentation. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. Description | Concentration: - N-Petane: 22 %. - Toulene: 78 %.Color and Shape:LiquidReagecon Cetane Improver 2-Ethylhexyl Nitrate 0.1% Calibration Standard in Chevron Phillips High Cetane Reference Fuel
This Reagecon Cetane Improver Calibration Standard is a ready to use standard in Petroleum Ether used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing for 2-Ethylhexyl Nitrate a known Cetane improver, in Diesel, in accordance with the International Standard ASTM E1655, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS.Color and Shape:LiquidReagecon Cetane Improver 2-Ethylhexyl Nitrate 0.03% Calibration Standard in Chevron Phillips High Cetane Reference Fuel
This Reagecon Cetane Improver Calibration Standard is a ready to use standard in Petroleum Ether used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing for 2-Ethylhexyl Nitrate a known Cetane improver, in Diesel, in accordance with the International Standard ASTM E1655, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS.Color and Shape:LiquidReagecon Cetane Improver 2-Ethylhexyl Nitrate 0.5% Calibration Standard in Chevron Phillips High Cetane Reference Fuel
This Reagecon Cetane Improver Calibration Standard is a ready to use standard in Petroleum Ether used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing for 2-Ethylhexyl Nitrate a known Cetane improver, in Diesel, in accordance with the International Standard ASTM E1655, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS.Color and Shape:LiquidReagecon Vapour Pressure Calibration Standard (2 Compound Mix), D5191
This Reagecon Vapour Pressure Calibration Standard 2 Compound Mix is a ready to use standard used as either a calibrant or as an analytical quality control material for standard test methods for vapour pressure measurement of petroleum products and liquid fuels. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - This standard is used in in accordance with the International Standard ASTM D5191 using infrared (IR) instrumentation. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. Description | Concentration: - N-Petane: 44 %. - Toulene: 56 %.Color and Shape:LiquidReagecon Polycyclic Aromatic Hydrocarbon (PAH) Single Compound Standard 3-Hydroxybenzo[a]pyrene 50 µg/mL in Toluene
This Reagecon Polycyclic Aromatic Hydrocarbon (PAH) Single Compound Standard is a ready to use product that is used either as a calibrant or analytical control solution for a variety of gas and liquid chromatography methods that include GC; GC-MS; HPLC and LC-MS. This product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. - The identity of each standard is verified using a high performance calibrated Gas Chromatograph Mass Spectrometer (GC-MS Instrument). The mass spectrum of each of the analytes is confirmed by comparison with the National Institute of Standards and Technology (NIST) mass spectral library. - Ready to use (dilute for use as calibration and/or quality control standards). - Can be used with a variety of instruments including GC; GC-MS; HPLC and LC-MS. - Produced in accordance with EPA methods. - Designed for use in EPA or EU analytical methods. - Ideal for use in EPA 500; 600 and 8000 series methods. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Gasoline Calibration Standard (3 Compound Mix) in Petroleum Ether
CAS:This Reagecon Gasoline Calibration Standard (3 Compound Mix) in Petroleum Ether is a ready to use standard used in fuel analysis as either a calibrant or analytical control solution. This standard is used in testing for a range of Aromatic and Oxygenate compounds in Gasoline in accordance with the ASTM D5845, using infrared (IR) instrumentation. The product can also be used to validate appropriate test methods or qualify an instrument in a regulated industry. The product is QC tested on a high performance GC-MS. Description | Concentration: - ETBE: 20 %. - Methanol: 6 %. - Petroleum Ether: 54 %. - TAME: 20 %.Color and Shape:LiquidReagecon Ion Chromatography (IC) Multi Element Anion Standard (6 Elements) in Water (H₂O)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Chloride (Cl⁻): 1000 µg/mL (ppm). - Phosphate (PO₄³): 1000 µg/mL (ppm). - Nitrate (NO₃): 1000 µg/mL (ppm). - Sulphate (SO₄²): 1000 µg/mL (ppm). - Fluoride (F⁻): 100 µg/mL (ppm). - Bromide (Br⁻): 100 µg/mL (ppm).Color and Shape:LiquidReagecon pH 4.00 Mercury Free Colour Coded Buffer Solution at 25°C
Reagecon’s Mercury Free pH Buffer Solution at 25°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Buffer Standard pH 9.225 at 20°C NIST Value ISO 17034 Certified Reference Material
Reagecon's Buffer Standard pH 9.225 at 20°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:LiquidReagecon Buffer Standard pH 7.000 at 25°C High Resolution Colour Coded ISO 17034 Certified Reference Material
Reagecon's Buffer Standard pH 7.000 at 25°C Certified Reference Material is colour coded for ease of use; produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:LiquidReagecon Buffer Standard pH 9.180 at 25°C DIN 19266 ISO 17034 Certified Reference Material
Reagecon's Buffer Standard pH 9.180 at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:LiquidReagecon Buffer Standard pH 10.062 at 20°C NIST Value ISO 17034 Certified Reference Material
Reagecon's Buffer Standard pH 10.062 at 20°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:LiquidReagecon Manganese Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in Water (H₂O)
Reagecon's Manganese Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in H₂O is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Buffer Standard pH 9.00 at 25°C ISO 17034 Certified Reference Material
Reagecon's Buffer Standard pH 9.00 at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:LiquidReagecon Buffer Standard pH 9.23 at 25°C DIN 19267 ISO 17034 Certified Reference Material
Reagecon's Buffer Standard pH 9.23 at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:LiquidReagecon Buffer Standard pH 6.86 at 25°C ISO 17034 Certified Reference Material
Reagecon's Buffer Standard pH 6.86 at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:LiquidReagecon Buffer Standard pH 6.865 at 25°C DIN 19266 ISO 17034 Certified Reference Material
Reagecon's Buffer Standard pH 6.865 at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:LiquidReagecon Buffer Standard pH 6.00 at 20°C ISO 17034 Certified Reference Material
Reagecon's Buffer Standard pH 6.00 at 20°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:LiquidReagecon Buffer Standard pH 8.00 at 25°C ISO 17034 Certified Reference Material
Reagecon's Buffer Standard pH 8.00 at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:LiquidReagecon Calcium Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in Water (H₂O)
Reagecon's Calcium Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in H₂O is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Buffer Standard pH 4.005 at 25°C DIN 19266 ISO 17034 Certified Reference Material
Reagecon's Buffer Standard pH 4.005 at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:LiquidReagecon Perchloric Acid 0.1M (0.1N) in Acetic Acid Analytical Volumetric Solution (AVL)
Reagecon's Perchloric Acid 0.1M (0.1N) in Acetic Acid Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Density Standard Quality Range 0.7721 g/mL at 15°C
This Reagecon Density Standard Quality Range 0.7721 g/mL at 15°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%Color and Shape:LiquidReagecon Clinical Standard Sodium 150mmol/l and Potassium 100mmol/l for Flame Photometry
Reagecon's Sodium 150mmol/l and Potassium 100mmol/l Standard for Flame Photometry is manufactured from ultra-pure salts. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2% for each cation. The results are reported in mg/L on the basis of weight. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon 60 NTU Non Ratio Turbidity Standard
Reagecon 60 NTU Non Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for non-ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - These Turbidity Standards remove the handling; stability and accuracy problems associated with traditional Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon 1300 ppm Chemical Oxygen Demand Standard
This highly accurate 1300 ppm Chemical Oxygen Demand (COD) Calibration Standard, can be used to calibrate, control, verify or validate all COD Test Methods. The product yields an accurate test result of 1300 ppm. Achieving this correct result increases significantly the confidence of the analyst in the correct COD reading of the sample. - Reagecon’s COD Standards are ideal for use as Control Standards to verify that correct analysis for COD has taken place. Achieving an acceptable result for the Control Standard will improve confidence in sample readings for this important environmental parameter. - Used as a Control Standard; or for Validation or Qualification. - Directly traceable to NIST standard reference materials. - Run Control with each set of samples. - Prepare and analyse in exactly the same way as samples. - Manufactured to exacting specifications with an extended shelf life and stability. - Proven compliance with EPA. - Compatible with any instrument.Color and Shape:Liquid