
Physicochemical Standards
Physicochemical standards are essential reference materials used to ensure the accuracy and reliability of various analytical measurements in scientific research and industrial applications. This category includes a wide range of standards such as conductivity standards, electrochemistry standards, and ICP-OES/ICP-MS standards and reagents, which are critical for precise elemental analysis and conductivity measurements. pH buffer solutions and total organic/inorganic carbon reagents are vital for maintaining pH levels and measuring carbon content in samples. Standards from European Pharmacopoeia (EP), United States Pharmacopoeia (USP), and other pharmacopoeias provide benchmarks for pharmaceutical quality control. Additional standards like turbidity, density, refractometry, and viscosity standards ensure accurate physical property measurements. Specialized standards, such as those for wine, dairy, and petrochemical industries, support quality control and regulatory compliance in specific sectors. These physicochemical standards play a crucial role in ensuring the validity and reproducibility of experimental results, supporting a wide range of applications from environmental monitoring to pharmaceutical testing and materials science.
Subcategories of "Physicochemical Standards"
- Colour Standards(74 products)
- Cryoscope Standards(10 products)
- Density Standards(107 products)
- Melting Point Standards(16 products)
- Osmolality Standards(27 products)
- Refractive Index Standards(96 products)
- Turbidity Standards(137 products)
- Viscosity Standards(75 products)
Found 3970 products of "Physicochemical Standards"
Sort by
The purity filter is not visible because current products do not have associated purity data for filtering.
Reagecon 500 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (10 Elements) in 2-5% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2-5% HNO₃ is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Selenium (Se): 40 µg/mL (ppm). - Copper (Cu): 100 µg/mL (ppm). - Lithium (Li): 100 µg/mL (ppm). - Nickel (Ni): 100 µg/mL (ppm). - Strontium (Sr): 100 µg/mL (ppm). - Zinc (Zn): 100 µg/mL (ppm). - Aluminium (Al): 200 µg/mL (ppm). - Iron (Fe): 200 µg/mL (ppm). - Phosphorus (P): 500 µg/mL (ppm). - Boron (B): 1000 µg/mL (ppm).Color and Shape:LiquidReagecon Hydrochloric Acid 0.01N Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP) Concentrate
Reagecon's Hydrochloric Acid 0.01N Dissolution Media Concentrate is presented in concentrate form. This concentrate measures 230.85ml in volume in each bottle and the contents of each bottle can be diluted to produce 6L of working solution in water. This diluted volume is the working Dissolution Medium. The product is prepared and when diluted can be used in accordance with relevant pharmacopoeia requirements. - This product is presented as a concentrate in order to facilitate easy shipping, storage and handling. - The pack contains 12 bottles, each of which has a volume of 230.85ml of solution, each 230.85ml bottle is diluted to give 6L of ready to use Dissolution Medium.Color and Shape:LiquidReagecon Copper (Cu) 0.1% Standard Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.2) Limit Test
Reagecon's Copper (Cu) 0.1% Standard Solution is used in the preparation of other reagents and as specified in individual monographs. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density to a specification of ± 0.2%. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 4.01 Buffer Solution at 25°C according to European Pharmacopoeia (EP)
Reagecon's pH Buffer Solution at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable; has guaranteed stability throughout its entire shelf life; even after opening the bottle. The product is developed; formulated and specified in accordance with EP requirements. - NIST traceableColor and Shape:LiquidReagecon Molybdenum Standard for Atomic Absorption (AAS) 1000 µg/mL (1000 ppm) in Water (H₂O)
Reagecon's Molybdenum Standard for Atomic Absorption (AAS) 1000 µg/mL in Water (H₂O) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Spectrophotometry Caffeine Absorbance/Transmission (Linearity) Standard 25 mg/L (5ml)
Reagecon Spectrophotometry Caffeine Absorbance/Transmission (Linearity) Standard 25 mg/L is a standard which gives a spectral scan at various wavelengths. - ACCREDITED CALIBRATION: Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for the calibration of laboratory balances. This accreditation underscores our commitment to quality and reliability.Color and Shape:LiquidReagecon Iodide Standard for Ion Chromatography (IC) 0.1 mg/mL (100 ppm) in Water (H₂O)
Reagecon's Iodide Standard for Ion Chromatography (IC) 0.1 mg/mL (100 ppm) in H₂O is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Osmolality Standard 290 mOsm/Kg
Reagecon's Osmolality Standard 290 mOsm/kg is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). The Osmolality results are reported in milliOsmoles per kilogram water (mOsm/kg H₂O shortened to mOsm/kg for routine use). This product is manufactured in compliance with European; United States and Chinese Pharmacopoeia guidelines where appropriate. - Manufactured in accordance with European and United States Pharmacopoeia guidelines where appropriate. - These standards are used for calibration; quality control; method validation and instrument calibration irrespective of brand. - Low Uncertainty of Measurement. - Manufactured to exacting specifications with an extended shelf life and stability. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Brix Standard (Stabilised) 10% at 20°C
Reagecon's Brix Standard (Stabilised) 10% at 20°C is a high quality product; with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Brix determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer; manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for the test method used to certify this product (TPR1A 01). - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.11%. It is stable for one year; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.11%) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (32 Elements) in 2-5% Nitric Acid (HNO₃)
Reagecon's Multi Element Standard for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Aluminium (Al): 10 µg/mL (ppm). - Antimony (Sb): 10 µg/mL (ppm). - Arsenic (As): 10 µg/mL (ppm). - Barium (Ba): 10 µg/mL (ppm). - Beryllium (Be): 10 µg/mL (ppm). - Bismuth (Bi): 10 µg/mL (ppm). - Cadmium (Cd): 10 µg/mL (ppm). - Calcium (Ca): 10 µg/mL (ppm). - Cesium (Cs): 10 µg/mL (ppm). - Chromium (Cr): 10 µg/mL (ppm). - Cobalt (Co): 10 µg/mL (ppm). - Copper (Cu): 10 µg/mL (ppm). - Gallium (Ga): 10 µg/mL (ppm). - Indium (In): 10 µg/mL (ppm). - Iron (Fe): 10 µg/mL (ppm). - Lead (Pb): 10 µg/mL (ppm). - Lithium (Li): 10 µg/mL (ppm). - Magnesium (Mg): 10 µg/mL (ppm). - Manganese (Mn): 10 µg/mL (ppm). - Molybdenum (Mo): 10 µg/mL (ppm). - Nickel (Ni): 10 µg/mL (ppm). - Potassium (K): 10 µg/mL (ppm). - Rubidium (Rb): 10 µg/mL (ppm). - Selenium (Se): 10 µg/mL (ppm). - Silver (Ag): 10 µg/mL (ppm). - Sodium (Na): 10 µg/mL (ppm). - Strontium (Sr): 10 µg/mL (ppm). - Thallium (Tl): 10 µg/mL (ppm). - Tin (Sn): 10 µg/mL (ppm). - Uranium (U): 10 µg/mL (ppm). - Vanadium (V): 10 µg/mL (ppm). - Zinc (Zn): 10 µg/mL (ppm).Color and Shape:LiquidReagecon Ethanol Density Standard 20% v/v Ethanol/Water (Nominal Density 0.97356 g/mL)
Color and Shape:LiquidReagecon Sodium Standard for Atomic Absorption (AAS) 0.5 µg/mL (5 ppm) in 2% Nitric Acid (HNO₃)
Reagecon's Sodium Standard for Atomic Absorption (AAS) 0.5 µg/mL in 2% Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (14 Elements) in 5% Nitric Acid (HNO₃) and 1% Hydrochloric Acid (HCl)
Reagecon’s Multi Element Standards for ICP; ICP-MS in 5% Nitric Acid (HNO₃) and 1% Hydrochloric Acid (HCl) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Arsenic (As): 15 µg/mL (ppm). - Cadmium (Cd): 2 µg/mL (ppm). - Cobalt (Co): 5 µg/mL (ppm). - Lead (Pb): 5 µg/mL (ppm). - Copper (Cu): 300 µg/mL (ppm). - Mercury (Hg): 3 µg/mL (ppm). - Lithium (Li): 250 µg/mL (ppm). - Nickel (Ni): 20 µg/mL (ppm). - Palladium (Pd): 10 µg/mL (ppm). - Vanadium (V): 10 µg/mL (ppm). - Antimony (Sb): 90 µg/mL (ppm). - Tin (Sn): 600 µg/mL (ppm). - Chromium (Cr): 1100 µg/mL (ppm). - Molybdenum (Mo): 1500 µg/mL (ppm).Color and Shape:LiquidReagecon Potassium Pyroantimonate Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Potassium Pyroantimonate Solution is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include use in the identification reactions of ions and functional groups (2.3.1) and used as a reagent in the performance of tests outlined in several EP monographs. - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (12 Elements) in 2% Nitric Acid (HNO₃) and trace Hydrofluoric Acid (HF)
Reagecon’s Multi Element Standards for ICP; ICP-MS in 2% HNO₃ and trace HF is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Boron (B): 10 µg/mL (ppm). - Germanium (Ge): 10 µg/mL (ppm). - Molybdenum (Mo): 10 µg/mL (ppm). - Niobium (Nb): 10 µg/mL (ppm). - Phosphorus (P): 10 µg/mL (ppm). - Rhenium (Re): 10 µg/mL (ppm). - Sulfur (S): 10 µg/mL (ppm). - Silicon (Si): 10 µg/mL (ppm). - Tantalum (Ta): 10 µg/mL (ppm). - Titanium (Ti): 10 µg/mL (ppm). - Tungsten (W): 10 µg/mL (ppm). - Zirconium (Zr): 10 µg/mL (ppm).Color and Shape:LiquidReagecon Ethanol Density Standard 11% v/v Ethanol/Water (Nominal Density 0.98352 g/mL)
Color and Shape:LiquidReagecon Chloride Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in Water (H₂O)
Reagecon's Chloride Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in H₂O is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Thorium Standard for Atomic Absorption (AAS) 10,000 µg/mL (10,000 ppm) in 1M Nitric Acid (HNO₃)
Reagecon's Thorium Standard for Atomic Absorption (AAS) 10;000 µg/mL in 1M Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Ion Chromatography (IC) Multi Element Anion Standard (7 Elements) in Water (H₂O)
Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Flerovium (Fl): 50 µg/mL (ppm). - Chloride (Cl⁻): 50 µg/mL (ppm). - Bromide (Br⁻): 50 µg/mL (ppm). - Nitrite (NO₂): 50 µg/mL (ppm). - Nitrate (NO₃): 50 µg/mL (ppm). - Phosphate (PO₄³): 50 µg/mL (ppm). - Sulphate (SO₄²): 50 µg/mL (ppm).Color and Shape:LiquidReagecon Sulphur Standard for ICP, ICP-MS 10,000 µg/mL (10,000 ppm) in Water (H₂O)
Reagecon's Sulphur Standard for ICP; ICP-MS 10;000 µg/mL (10;000 ppm) in Water (H₂O) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 7.00 Technical Colour Coded Buffer Solution at 25°C
Reagecon’s Technical pH Buffer Solution at 25°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Refractive Index Standard (Solvent Based) 1.40485 nD units at 20°C
CAS:Reagecon's Refractive Index Standards (Solvent Based) 1.40485 nD at 20°C is a high quality product; with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Refractive Index determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer; manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for the test method. - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.00014 nD units. It is stable for two years; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.00014 nD units) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon Platinum-Cobalt (Hazen) 30 Colour Standard
Reagecon's Platinum-Cobalt (Hazen) 30 Colour Standard can be used to calibrate, control, qualify or validate colour measurement instruments. This standard can be described as Platinum-Cobalt, Pt-Co, Hazen or APHA colour. All descriptions are interchangeable. This product is used extensively in the water industry and several other industries. The standard covers the requirements of ASTM Method D 1209.Color and Shape:LiquidReagecon Yttrium Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)
Reagecon's Yttrium Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Benzethonium Chloride 0.04M (0.04N) Analytical Volumetric Solution (AVL)
Reagecon's Benzethonium Chloride 0.04M (0.04N) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Chemical Oxygen Demand (COD) Vials 0-150 mg/L
Reagecon's Chemical Oxygen Demand (COD) vials 0-150 mg/l can be used in conjunction with the Hach®, Aqualytic PC Spectro® and Aqualytic PC Compact Vario® Spectrophotometers that accept 16mm vials. - Ready to use in 16mm diameter vials. - Compatible with all dedicated spectrophotometer brands. - Use in the same way as instrument manufacturer’s vials. - See More on Reagecon's Chemical Oxygen Demand (COD) Vials COD Vials - Product Instruction-Information Sheet - It is considered best practice to always include a COD control standard when testing samples, with the value of the control standard close to the expected COD value for your samples. Reagecon supply a wide range of Chemical Oxygen Demand (COD) Standards which can be used for this purpose.Color and Shape:LiquidReagecon Hydrochloric Acid 0.1N according to United States Pharmacopoeia (USP)
Reagecon's Hydrochloric Acid 0.1N is a fully factorised, high purity, stable product, developed and tested for titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.2%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties as detailed in several USP monographs. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stochiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Calcium Standard for Atomic Absorption (AAS) 100 µg/mL (100 ppm) 0.5M Nitric Acid (HNO₃)
Reagecon's Calcium Standard for Atomic Absorption (AAS) 100 µg/mL in 0.5M Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 4.01 Colour Coded Buffer Solution at 25°C in Twin Neck
Reagecon's pH Buffer Solution at 25°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Zinc Chloride Solution Iodinated according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
CAS:Reagecon Zinc Chloride Solution Iodinated is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include use as a reagent in the performance of tests outlined in several EP monographs. - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Arsenic (V) Standard for Atomic Absorption (AAS) 1000 µg/mL (1000 ppm) in 1M Nitric Acid (HNO₃)
Reagecon's Arsenic (V) Standard for Atomic Absorption (AAS) 1000 µg/mL in 1M Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Sodium Nitrite 0.5M (0.5N) Analytical Volumetric Solution (AVL)
Reagecon's Sodium Nitrite 0.5M (0.5N) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Platinum-Cobalt (Hazen) 20 Colour Standard
Reagecon's Platinum-Cobalt (Hazen) 20 Colour Standard can be used to calibrate, control, qualify or validate colour measurement instruments. This standard can be described as Platinum-Cobalt, Pt-Co, Hazen or APHA colour. All descriptions are interchangeable. This product is used extensively in the water industry and several other industries. The standard covers the requirements of ASTM Method D 1209.Color and Shape:LiquidReagecon 4 NTU Non Ratio Turbidity Standard
Reagecon 4 NTU Non Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for non-ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - These Turbidity Standards remove the handling; stability and accuracy problems associated with traditional Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon Brix Standard (Stabilised) 45% at 20°C
Reagecon's Brix Standard (Stabilised) 45% at 20°C is a high quality product; with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Brix determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer; manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for the test method used to certify this product (TPR1A 01). - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.11%. It is stable for one year; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.11%) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon 20 NTU Turbiform™ Stabilised Formazin Turbidity Standard
This standard is an aqueous suspension of a formazin type product that carries all of the advantages of formazin but eliminates its shortcomings. It is stable; safe; EPA approved and accurate. - Reagecon have developed a proprietary synthetic process that produces a family of products called Turbiform™. These products combine most of the positive attributes of the formazin and AMCO APEA-1 range of standards already available from Reagecon; whilst eliminating most of the shortcomings. Most importantly; this process does not interfere adversely with the status of formazin as the recognised primary standard. - Product exhibits a wide range of particle sizes; shapes and slopes (similar to formazin) mean diameter 3 µm with distribution of between 1 and 20 microns; which are similar to the particle size and distribution found in most sample types. - This product can be used to calibrate; control; validate or qualify; almost any make or model of Turbidity measuring instrument. - Traceable to NIST reference material 1690 and 1691 - Can be used to calibrate; control; validate or qualify almost any make or model of instrumentColor and Shape:LiquidReagecon Melting Point Caffeine 235 °C to 238 °C Standard
Reagecon's Melting Point Caffeine 235 °C to 238 °C Standard is an ultrapure substance; specially prepared to calibrate; control; verify or qualify Melting Point (MP) apparatus. The exceptional purity of this product is critical as MP will change with the presence of very small quantities of impurities. This product is produced in accordance with the European; US and Chinese Pharmacopeia requirements. The product can assist in identifying a compound or derivative or checking the purity or thermal stability of a known compound. - This product is tested using Melting Point apparatus that is traceable to the ITS-90 Temperature Scale.Color and Shape:SolidReagecon ICP, ICP-MS Multi Element Standard (2 Elements) in Water (H₂O)
Reagecon’s Multi Element Standards for ICP; ICP-MS in Water (H₂O) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Sulfur (S): 100 µg/mL (ppm). - Silicon (Si): 100 µg/mL (ppm).Color and Shape:LiquidReagecon Refractive Index Standard (Solvent Based) 1.50044 nD units at 20°C
CAS:Reagecon's Refractive Index Standards (Solvent Based) 1.50044 nD at 20°C is a high quality product; with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Refractive Index determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer; manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for the test method. - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.00014 nD units. It is stable for two years; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.000158 nD units) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon Ion Chromatography (IC) Multi Element Anion Standard (3 Elements) in Water (H₂O)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Sulphate (SO₄²): 1000 µg/mL (ppm). - Fluoride (F⁻): 1000 µg/mL (ppm). - Chloride (Cl⁻): 1000 µg/mL (ppm).Color and Shape:LiquidReagecon Sodium Chloride 0.05M (0.05N) Analytical Volumetric Solution (AVL)
Reagecon's Sodium Chloride 0.05M (0.05N) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Osmolality Standard 300 mOsm/Kg
Reagecon's Osmolality Standard 300 mOsm/kg is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). The Osmolality results are reported in milliOsmoles per kilogram water (mOsm/kg H₂O shortened to mOsm/kg for routine use). This product is manufactured in compliance with European; United States and Chinese Pharmacopoeia guidelines where appropriate. - Manufactured in accordance with European and United States Pharmacopoeia guidelines where appropriate. - These standards are used for calibration; quality control; method validation and instrument calibration irrespective of brand. - Low Uncertainty of Measurement. - Manufactured to exacting specifications with an extended shelf life and stability. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Ion Chromatography (IC) Multi Element Cation Standard (6 Elements) in Water (H₂O)
Reagecon's Ion Chromatography (IC) Multi Element Cation Standard (6 Elements) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Calcium (Ca): 1000 µg/mL (ppm). - Ammonium (NH4): 1000 µg/mL (ppm). - Sodium (Na): 1000 µg/mL (ppm). - Potassium (K): 1000 µg/mL (ppm). - Magnesium (Mg): 1000 µg/mL (ppm). - Lithium (Li): 1000 µg/mL (ppm).Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (48 Elements) in 2-5% Nitric Acid (HNO₃)
Reagecon's Multi Element Standard for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Aluminium (Al): 10 µg/mL (ppm). - Arsenic (As): 10 µg/mL (ppm). - Barium (Ba): 10 µg/mL (ppm). - Beryllium (Be): 10 µg/mL (ppm). - Bismuth (Bi): 10 µg/mL (ppm). - Boron (B): 10 µg/mL (ppm). - Cadmium (Cd): 10 µg/mL (ppm). - Calcium (Ca): 10 µg/mL (ppm). - Cerium (Ce): 10 µg/mL (ppm). - Cesium (Cs): 10 µg/mL (ppm). - Chromium (Cr): 10 µg/mL (ppm). - Cobalt (Co): 10 µg/mL (ppm). - Copper (Cu): 10 µg/mL (ppm). - Dysprosium (Dy): 10 µg/mL (ppm). - Erbium (Er): 10 µg/mL (ppm). - Europium (Eu): 10 µg/mL (ppm). - Gadolinium (Gd): 10 µg/mL (ppm). - Gallium (Ga): 10 µg/mL (ppm). - Holmium (Ho): 10 µg/mL (ppm). - Indium (In): 10 µg/mL (ppm). - Iron (Fe): 10 µg/mL (ppm). - Lanthanum (La): 10 µg/mL (ppm). - Lead (Pb): 10 µg/mL (ppm). - Lithium (Li): 10 µg/mL (ppm). - Lutetium (Lu): 10 µg/mL (ppm). - Magnesium (Mg): 10 µg/mL (ppm). - Manganese (Mn): 10 µg/mL (ppm). - Neodymium (Nd): 10 µg/mL (ppm). - Nickel (Ni): 10 µg/mL (ppm). - Phosphorus (P): 10 µg/mL (ppm). - Potassium (K): 10 µg/mL (ppm). - Praseodymium (Pr): 10 µg/mL (ppm). - Rhenium (Re): 10 µg/mL (ppm). - Rubidium (Rb): 10 µg/mL (ppm). - Samarium (Sm): 10 µg/mL (ppm). - Scandium (Sc): 10 µg/mL (ppm). - Selenium (Se): 10 µg/mL (ppm). - Sodium (Na): 10 µg/mL (ppm). - Strontium (Sr): 10 µg/mL (ppm). - Terbium (Tb): 10 µg/mL (ppm). - Thallium (Tl): 10 µg/mL (ppm). - Thorium (Th): 10 µg/mL (ppm). - Thulium (Tm): 10 µg/mL (ppm). - Uranium (U): 10 µg/mL (ppm). - Vanadium (V): 10 µg/mL (ppm). - Ytterbium (Yb): 10 µg/mL (ppm). - Yttrium (Y): 10 µg/mL (ppm). - Zinc (Zn): 10 µg/mL (ppm).Color and Shape:LiquidReagecon Saybolt +19 Colour Standard
Reagecon's Saybolt +19 Colour Standard can be used to calibrate, control, qualify or validate colour measurement instruments. This includes ASTM specified methods D 156 and D 6045. The standard is particularly suited for colour grading light coloured petroleum products.Color and Shape:LiquidReagecon Sodium Thiosulphate 0.05M (0.05N) Analytical Volumetric Solution (AVL)
Reagecon's Sodium Thiosulphate 0.05M (0.05N) Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for oxidation/reduction titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Oxidation/reduction titrations depend on changes in the electropotential of the oxidation reduction system and always involves a reaction between an oxidising and reducing pair. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Hydrochloric Acid 6.0M (6.0N) Analytical Volumetric Solution (AVL)
Reagecon's Hydrochloric Acid 6.0M (6.0N) Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (8 Elements) in 5% Hydrochloric Acid (HCl)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 5% Hydrochloric Acid (HCl) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Chromium (Cr): 100 µg/mL (ppm). - Cadmium (Cd): 100 µg/mL (ppm). - Copper (Cu): 100 µg/mL (ppm). - Palladium (Pd): 100 µg/mL (ppm). - Zinc (Zn): 100 µg/mL (ppm). - Nickel (Ni): 100 µg/mL (ppm). - Manganese (Mn): 100 µg/mL (ppm). - Barium (Ba): 100 µg/mL (ppm).Color and Shape:LiquidReagecon 475 mV Redox Oxidation/Reduction (ORP) Standard at 25°C
This Reagecon's 475 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 475 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.Color and Shape:LiquidReagecon N35 Kinematic Viscosity, Dynamic Viscosity and Density Standard
Reagecon’s N35 Kinematic Viscosity, Dynamic Viscosity and Density Standard can be used to calibrate, control or validate all types of viscometers including capillary, flow cup, rotational, falling ball, falling/rising object, stabinger and vibrational viscometers.This Viscosity Standard and all Reagecon Viscosity Standards are reported to 4 significant figures on their Certificate of Analysis.Only 2 significant figures are shown here for expediency of layout. - This product has been tested according to ASTM method D 2162 for Kinematic Viscosity using Ubbelohde Master Viscometers. - The Density has been tested in accordance with ASTM method D4052 (Kinematic Viscosity x Density = Dynamic Viscosity). - Kinematic Viscosity values and Density values are traceable to the Primary Standard of pure water at 20°C as adopted by NIST. Temperature values are traceable via National Standards to the ITS-90 temperature scale.Color and Shape:LiquidReagecon pH 3.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Density Standards Premium Range 0.8027 g/mL at 60°C
This Reagecon Density Standard Premium Range 0.8027 g/mL at 60°C is manufactured and tested in accordance with ASTM D1480-12 for testing of density or relative density (specific and API gravity). It is tested by Bingham Pycnometry and can be used as a calibration or control standard for density measurement by pycnometer, vibrational, or hydrometer (specific gravity) based techniques. - High accuracy - Tested using a fundamental measurement technique (Bingham Pycnometer)Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (4 Elements) in 2-5% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standard for ICP; ICP-MS in 2-5% HNO₃ is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Calcium (Ca): 1000 µg/mL (ppm). - Magnesium (Mg): 1000 µg/mL (ppm). - Sodium (Na): 1000 µg/mL (ppm). - Phosphorus (P): 1000 µg/mL (ppm).Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (5 Elements) in 2-5% Nitric Acid (HNO₃) and 1% Hydroflouric Acid (HF)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) and 1% Hydroflouric Acid (HF) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Silicon (Si): 1000 µg/mL (ppm). - Titanium (Ti): 1000 µg/mL (ppm). - Molybdenum (Mo): 1000 µg/mL (ppm). - Tin (Sn): 1000 µg/mL (ppm). - Antimony (Sb): 1000 µg/mL (ppm).Color and Shape:LiquidReagecon Thallium Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)
Reagecon's Thallium Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Methyl Orange Indicator 0.1% Alcoholic Solution
Reagecon's Methyl Orange Indicator 0.1% Alcoholic Solution is a high quality Indicator Solution produced from the highest quality raw materials and manufactured and tested under rigorous conditions. For manual titrations; indicator titrant or analyte change colour and this colour change is by far the most important method of end point detection, in such titrations. A high quality indicator solution such as Reagecon's Methyl Orange Indicator 0.1% Alcoholic Solution facilitates end point detection, in a clear and unambiguous manner and is an imperative for accurate manual titrimetry.Color and Shape:LiquidReagecon Concentrate to make Sodium (Na) 200ppm Standard Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.2) Limit Test
Reagecon's Concentrate to make Sodium (Na) 200ppm Standard Solution is used in the preparation of other reagents and as specified in individual monographs. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density to a specification of ± 0.2%. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (16 Elements) in 5% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 5% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Cerium (Ce): 100 µg/mL (ppm). - Lanthanum (La): 100 µg/mL (ppm). - Neodymium (Nd): 100 µg/mL (ppm). - Praseodymium (Pr): 100 µg/mL (ppm). - Dysprosium (Dy): 20 µg/mL (ppm). - Erbium (Er): 20 µg/mL (ppm). - Europium (Eu): 20 µg/mL (ppm). - Gadolinium (Gd): 20 µg/mL (ppm). - Holmium (Ho): 20 µg/mL (ppm). - Lutetium (Lu): 20 µg/mL (ppm). - Scandium (Sc): 20 µg/mL (ppm). - Samarium (Sm): 20 µg/mL (ppm). - Terbium (Tb): 20 µg/mL (ppm). - Thulium (Tm): 20 µg/mL (ppm). - Yttrium (Y): 20 µg/mL (ppm). - Ytterbium (Yb): 20 µg/mL (ppm).Color and Shape:LiquidReagecon Ammonium Chloride TS Solution according to United States Pharmacopoeia (USP)
Reagecon's Ammonium Chloride TS Solution according to United States Pharmacopoeia (USP) is specified for use in individual United States Pharmacopoeia (USP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03); is NIST traceable and has guaranteed stability throughout its entire shelf life; even after opening the bottle.Color and Shape:LiquidReagecon pH 7.00 Colour Coded Buffer Solution at 25°C in Twin Neck
Reagecon's pH Buffer Solution at 25°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (3 Elements) in 5% Nitric Acid (HNO₃) and 0.5% Hydrochloric Acid (HCl)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 5% HNO₃ and 0.5% HCl is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Gallium (Ga): 50 µg/mL (ppm). - Iridium (Ir): 10 µg/mL (ppm). - Rhodium (Rh): 10 µg/mL (ppm).Color and Shape:LiquidReagecon Simulated Gastric Fluid (M) pH 1.20 Dissolution Media
Reagecon's Simulated Gastric Fluid (M) pH 1.20 Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon Ammonia Test Solution according to Japanese Pharmacopoeia
CAS:Reagecon's Ammonia Test Solution is a high purity stable product developed and tested for several Japanese Pharmacopoeia (JP) applications. - This Reagecon JP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Thorium Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)
Reagecon's Thorium Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 12.627 NIST Value Buffer Solution at 20°C
Reagecon’s NIST Value pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Refractive Index Standard (Stabilised Sucrose) 1.37233 nD units at 20°C
Reagecon's Refractive Index Standards (Stabilised Sucrose) 1.37233 nD at 20°C is a high quality product, with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Refractive Index determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer, manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation for the test method used to certify this product. - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.00014 nD units. It is stable for one year; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.00014 nD units) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon Universal Indicator Solution
Reagecon's Universal Indicator Solution is a high quality Indicator Solution produced from the highest quality raw materials and manufactured and tested under rigorous conditions. For manual titrations; indicator titrant or analyte change colour and this colour change is by far the most important method of end point detection, in such titrations. A high quality indicator solution such as Reagecon's Universal Indicator Solution facilitates end point detection, in a clear and unambiguous manner and is an imperative for accurate manual titrimetry.Color and Shape:LiquidReagecon Buffered Sodium Dodecyl Sulphate pH 7 Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP)
Reagecon's Buffered Sodium Dodecyl Sulphate pH 7 Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon pH 4.005 DIN 19266 Buffer Solution at 25°C in Twin Neck
Reagecon's DIN 19266 pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Clinical Standard Sodium 120mmol/l and Potassium 2 mmol/l for Flame Photometry
Reagecon's Sodium 120mmol/l and Potassium 2 mmol/l Standard for Flame Photometry is manufactured from ultra-pure salts. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2% for each cation. The results are reported in mg/L on the basis of weight. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (6 Elements) in 2-5% Hydrochloric Acid (HCl)
Reagecon's Multi Element Standard for ICP; ICP-MS in 2-5% Hydrochloric Acid (HCl) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Caesium Chloride (CsCl): 1000 µg/mL (ppm). - Calcium (Ca): 2 µg/mL (ppm). - Magnesium (Mg): 1 µg/mL (ppm). - Phosphorus (P): 10 µg/mL (ppm). - Potassium (K): 10 µg/mL (ppm). - Sodium (Na): 2 µg/mL (ppm).Color and Shape:LiquidReagecon Nitric Acid 5% w/v Analytical Volumetric Solution (AVL)
Reagecon's Nitric Acid 5% w/v Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon pH 8.50 Phosphate Buffer Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.3)
Reagecon’s pH 8.5 Phosphate Buffer Solution is specified for use in individual European Pharmacopoeia (EP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable; has guaranteed stability throughout its entire shelf life; even after opening the bottle. - NIST traceableColor and Shape:LiquidReagecon Barium Hydroxide Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Barium Hydroxide Solution is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include use in the identification reactions of ions and functional groups (2.3.1) and used as a reagent in the performance of tests outlined in several EP monographs. - NIST traceable - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon 8000 µS/cm Conductivity Standard at 25°C
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon pH 7.41 Buffer Solution at 25°C according to European Pharmacopoeia (EP)
Reagecon's pH Buffer Solution at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable; has guaranteed stability throughout its entire shelf life; even after opening the bottle. The product is developed; formulated and specified in accordance with EP requirements. - NIST traceableColor and Shape:LiquidReagecon Sodium Hydroxide 1.0M Solution according to Chinese Pharmacopoeia (ChP)
Reagecon's Sodium Thiosulfate 0.1M is a fully factorised, high purity, stable product, developed and tested for titrations. This is an Analytical Volumetric Solution, also called titrant, standard titrant or standard solution. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations also called potentiometric titration, to determine the end points by detection of any of several properties as detailed in several ChP monographs. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Acetate Buffer pH 4.5 Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP) Concentrate
Reagecon's Acetate Buffer pH 4.5 Dissolution Media Concentrate is presented in concentrate form. This concentrate measures 961.5ml in volume in each bottle and the contents of each bottle can be diluted to produce 25L of working solution in water. This diluted volume is the working Dissolution Medium. The product is prepared and when diluted can be used in accordance with relevant pharmacopoeia requirements. - This product is presented as a concentrate in order to facilitate easy shipping, storage and handling. - The pack contains 6 bottles, each of which has a volume of 961.5ml of solution, each 961.5ml bottle is diluted to give 25L of ready to use Dissolution Medium.Color and Shape:LiquidReagecon BY4 Colour Reference Solution according to European Pharmacopoeia (EP)
Reagecon’s BY4 Colour Reference Solution is formulated as a reference solution for the examination of the degree of colouration of liquids in accordance with the European Pharmacopoeia Chapter 2.2.2. This product is produced by combining Reagecon Primary Colour Solutions. - Concentration verified using a high performance spectrophotometerColor and Shape:LiquidReagecon Refractive Index Standard (Solvent Based) 1.38779 nD units at 20°C
Reagecon's Refractive Index Standards (Solvent Based) 1.38779 nD at 20°C is a high quality product; with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Refractive Index determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer; manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for the test method. - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.00014 nD units. It is stable for two years; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.00014 nD units) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon Carbon Dioxide Standard (CO₂) 4g/l
Reagecon’s Carbon Dioxide Standard (CO₂) 1 g/l is one of a series of standards used to calibrate and control the Corning 965D Carbon Dioxide Analyser. Use of this instrument is one of a number of approved techniques available for the determination of CO₂ in beer and other carbonated beverages. This instrument was subsequently marketed by Mettler Toledo as the model M965D CO₂ Analyser. - This product is produced using raw materials of a very high purity and specification. The product is tested titrimetrically using Reagecon’s in house method TPATB against Hydrochloric Acid, Analytical Volumetric Standard solution. This standard is directly traceable to NIST Standard Reference Material 723e - tris(hydroxymethyl)aminomethane. A detailed Certificate of Analysis is issued with each batch manufactured.Color and Shape:LiquidReagecon Ammonia, Ammonium Chloride Buffer TS Solution according to United States Pharmacopoeia (USP)
CAS:Reagecon's Ammonia; Ammonium Chloride Buffer TS Solution according to United States Pharmacopoeia (USP) is specified for use in individual United States Pharmacopoeia (USP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03); is NIST traceable and has guaranteed stability throughout its entire shelf life; even after opening the bottle.Color and Shape:LiquidReagecon 3.5M Potassium Chloride Electrode Filling Solution (Electrolyte) Free from Silver Ion
Concentrated or saturated Potassium Chloride (KCl) is the optimal electrolyte and filling solution for potentiometric titrations, direct pH measurement, redox or ion measurement where silver/silver chloride or calomel reference electrodes are used. However, saturated KCl is only sparingly soluble below 20°C, so if measurements below this temperature are to be carried out 3.5M Potassium Chloride remains in solution down to 15°C. - A good electrolyte must fulfil a number of conditions. The equitransference of the cation/anion combination should be as close as possible to being equimobile, have constant chloride activity, be of high electrical conductance and be as non-chemically reactive as possible. Reagecon 3.5M Potassium Chloride Electrode Filling Solution is a high quality product that fulfils all of these criteriaColor and Shape:LiquidReagecon Zinc Standard for ICP, ICP-MS 10,000 µg/mL (10,000 ppm) in 2-5% Nitric Acid (HNO₃)
Reagecon's Zinc Standard for ICP; ICP-MS 10;000 µg/mL (10;000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Bromide Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in Water (H₂O)
Reagecon's Bromide Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in H₂O is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Ion Chromatography (IC) Multi Element Anion Standard (3 Elements) in Water (H₂O)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Sulphate (SO₄²): 1000 µg/mL (ppm). - Fluoride (F⁻): 1000 µg/mL (ppm). - Chloride (Cl⁻): 1000 µg/mL (ppm).Color and Shape:LiquidReagecon Iodine 0.1M (0.2N) Analytical Volumetric Solution (AVL)
Reagecon's Iodine 0.1M (0.2N) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for oxidation/reduction titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties. Oxidation/reduction titrations depend on changes in the electropotential of the oxidation reduction system and always involves a reaction between an oxidising and reducing pair. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Refractive Index Standard (Stabilised Sucrose) 1.35568 nD units at 20°C
Reagecon's Refractive Index Standard (Stabilised Sucrose) 1.35568 nD units at 20°C is a high quality product, with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Refractive Index determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer, manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation for the test method used to certify this product. - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.00014 nD units. It is stable for one year; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.00014 nD units) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon pH 1.679 DIN 19266 Buffer Solution at 25°C in Twin Neck
Reagecon's DIN 19266 pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Sodium Standard for Atomic Absorption (AAS) 10 µg/mL (10 ppm) in 0.5M Nitric Acid (HNO₃)
Reagecon's Sodium Standard for Atomic Absorption (AAS) 10 µg/mL in 0.5M Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (21 Elements) in 5% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 5% HNO₃ is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Silver (Ag): 100 µg/mL (ppm). - Arsenic (As): 100 µg/mL (ppm). - Boron (B): 100 µg/mL (ppm). - Barium (Ba): 100 µg/mL (ppm). - Beryllium (Be): 100 µg/mL (ppm). - Calcium (Ca): 100 µg/mL (ppm). - Cadmium (Cd): 100 µg/mL (ppm). - Cerium (Ce): 100 µg/mL (ppm). - Cobalt (Co): 100 µg/mL (ppm). - Chromium (Cr): 100 µg/mL (ppm). - Copper (Cu): 100 µg/mL (ppm). - Mercury (Hg): 100 µg/mL (ppm). - Magnesium (Mg): 100 µg/mL (ppm). - Manganese (Mn): 100 µg/mL (ppm). - Nickel (Ni): 100 µg/mL (ppm). - Phosphorus (P): 100 µg/mL (ppm). - Lead (Pb): 100 µg/mL (ppm). - Selenium (Se): 100 µg/mL (ppm). - Strontium (Sr): 100 µg/mL (ppm). - Thallium (Tl): 100 µg/mL (ppm). - Vanadium (V): 100 µg/mL (ppm).Color and Shape:LiquidReagecon Tartrate Standard for Ion Chromatography (IC) 0.2 mg/mL (200 ppm) in Water (H₂O)
Reagecon's Tartrate Standard for Ion Chromatography (IC) 0.2 mg/mL (200 ppm) in H₂O is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:Liquid

