
Physicochemical Standards
Physicochemical standards are essential reference materials used to ensure the accuracy and reliability of various analytical measurements in scientific research and industrial applications. This category includes a wide range of standards such as conductivity standards, electrochemistry standards, and ICP-OES/ICP-MS standards and reagents, which are critical for precise elemental analysis and conductivity measurements. pH buffer solutions and total organic/inorganic carbon reagents are vital for maintaining pH levels and measuring carbon content in samples. Standards from European Pharmacopoeia (EP), United States Pharmacopoeia (USP), and other pharmacopoeias provide benchmarks for pharmaceutical quality control. Additional standards like turbidity, density, refractometry, and viscosity standards ensure accurate physical property measurements. Specialized standards, such as those for wine, dairy, and petrochemical industries, support quality control and regulatory compliance in specific sectors. These physicochemical standards play a crucial role in ensuring the validity and reproducibility of experimental results, supporting a wide range of applications from environmental monitoring to pharmaceutical testing and materials science.
Subcategories of "Physicochemical Standards"
- Colour Standards(74 products)
- Cryoscope Standards(10 products)
- Density Standards(107 products)
- Melting Point Standards(16 products)
- Osmolality Standards(27 products)
- Refractive Index Standards(96 products)
- Turbidity Standards(137 products)
- Viscosity Standards(75 products)
Found 3970 products of "Physicochemical Standards"
Sort by
The purity filter is not visible because current products do not have associated purity data for filtering.
Reagecon Density Standard Premium Range 0.8340 g/mL at 25°C
This Reagecon Density Standard Premium Range 0.8340 g/mL at 25°C is manufactured and tested in accordance with ASTM D1480-12 for testing of density or relative density (specific and API gravity). It is tested by Bingham Pycnometry and can be used as a calibration or control standard for density measurement by pycnometer, vibrational, or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using Bingham Pycnometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 Accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). The density of the product is established and tested using high performance calibrated reference pycnometers. - High accuracy (± 0.00077 g/ml) - Tested using a fundamental measurement technique (Bingham Pycnometer)Color and Shape:LiquidReagecon Spectrophotometry (Linearity) Blank 0.1M Hydrochloric Acid
Reagecon's Spectrophotometry (Linearity) Blank 0.1M Hydrochloric Acid is a standard which gives a spectral scan at wavelengths that include 231 and 261 nm.Color and Shape:LiquidReagecon 10,000 ppm Chemical Oxygen Demand Standard
This highly accurate 10,000 ppm Chemical Oxygen Demand (COD) Calibration Standard, can be used to calibrate, control, verify or validate all COD Test Methods. The product yields an accurate test result of 10,000 ppm. Achieving this correct result increases significantly the confidence of the analyst in the correct COD reading of the sample. - Reagecon’s COD Standards are ideal for use as Control Standards to verify that correct analysis for COD has taken place. Achieving an acceptable result for the Control Standard will improve confidence in sample readings for this important environmental parameter. - Used as a Control Standard; or for Validation or Qualification. - Directly traceable to NIST standard reference materials. - Run Control with each set of samples. - Prepare and analyse in exactly the same way as samples. - Manufactured to exacting specifications with an extended shelf life and stability. - Proven compliance with EPA. - Compatible with any instrument.Color and Shape:LiquidReagecon Hydrochloric Acid 0.02M (0.02N) Analytical Volumetric Solution (AVL)
Reagecon's Hydrochloric Acid 0.02M (0.02N) Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon 147 µS/cm Conductivity Standard at 25°C (CDt)
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon Acetate Buffer pH 5.5 Dissolution Media in accordance to European Pharmacopoeia (EP)
Reagecon's Acetate Buffer pH 5.5 Dissolution Media is a ready to use solution, specifically formulated to perform dissolution studies on solid form pharmaceutical preparations. The product is prepared in accordance with relevant Pharmacopoeia requirements, without any deviations in materials or methodology from the Pharmacopoeia methods. - The product has the reported accuracy and guaranteed stability of 2 years.Color and Shape:LiquidReagecon Release Agent 1.0% Lanthanum for Atomic Absorption (AAS) in Nitric Acid (HNO₃)
Reagecon’s Release Agent 1.0% Lanthanum for Atomic Absorption (AAS) is a high quality product designed and specified to react with certain interfering anions, so as to eliminate or reduce interference, thereby enhancing the prospect of greater accuracy whilst measuring the target cation. - This product is produced from at least 99.9% pure starting material, enabling the user to have a very low level of impurities in the final sample.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (12 Elements) in 2-5% Nitric Acid (HNO₃)
Reagecon's ICP; ICP-MS Multi Element Standard in 2-5% HNO₃ is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Antimony (Sb): 10 µg/mL (ppm). - Arsenic (As): 10 µg/mL (ppm). - Cadmium (Cd): 10 µg/mL (ppm). - Cobalt (Co): 10 µg/mL (ppm). - Copper (Cu): 10 µg/mL (ppm). - Chromium (Cr): 10 µg/mL (ppm). - Iron (Fe): 10 µg/mL (ppm). - Manganese (Mn): 10 µg/mL (ppm). - Molybdenum (Mo): 10 µg/mL (ppm). - Nickel (Ni): 10 µg/mL (ppm). - Lead (Pb): 10 µg/mL (ppm). - Selenium (Se): 10 µg/mL (ppm).Color and Shape:LiquidReagecon Spectrophotometry (Linearity) Blank 0.001M Perchloric Acid (USP)
Reagecon's Spectrophotometry (Linearity) Blank 0.001M Perchloric Acid (USP) is a standard which gives a spectral scan at various wavelengths that include 235, 257, 313 and 350 nm.Color and Shape:LiquidReagecon Silver Nitrate 0.0141M (0.0141N ) Analytical Volumetric Solution (AVL)
Reagecon's Silver Nitrate 0.0141M (0.0141N ) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for precipitation (argentometric) titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties. Precipitation titrimetry is based on reactions that yield compounds of limited solubility. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Sulphur Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in Water (H₂O)
Reagecon's Sulphur Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in Water (H₂O) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Total Base Number (TBN) Standard 0.5 mg/g Potassium Hydroxide (KOH)
Reagecon Total Base Number (TBN) Standard 0.5 mg/g Potassium Hydroxide (KOH) is a high quality standard that can be used to calibrate; control or validate the methodology or equipment used to perform TBN testing according to ASTM Method D2896. - Produced in accordance with ASTM D2896. - Test method D2896 is used for both new and used petroleum products that may contain basic constituents that may be present as additives. - The test method D2896 may also be used as a measure of lubricant degradation; but any condemning limits based on the test must be established on an individual basis. - Standards are traceable to NIST. - The method has a very low uncertainty of measurement. - Stability is proven (either opened or unopened) for the shelf life of this product. - Consistency of product - Independent; Traceable; Certified.Color and Shape:SolidReagecon Clinical Standard Sodium 100mmol/l and Potassium 100 mmol/l for Flame Photometry
Reagecon's Sodium 100mmol/l and Potassium 100 mmol/l Standard for Flame Photometry is manufactured from ultra-pure salts. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2% for each cation. The results are reported in mg/L on the basis of weight. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 4.00 Colour Coded Buffer Solution at 20°C
Reagecon's pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Platinum Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 5% Hydrochloric Acid (HCl)
Reagecon's Platinum Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 5% Hydrochloric Acid (HCl) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon N7.5 Kinematic Viscosity, Dynamic Viscosity and Density Standard to 100°C
Reagecon's N7.5 Kinematic Viscosity, Dynamic Viscosity and Density Standard can be used to calibrate, control or validate all types of viscometers including capillary, flow cup, rotational, falling ball, falling/rising object, stabinger and vibrational viscometers.This Viscosity Standard and all Reagecon Viscosity Standards are reported to 4 significant figures on their Certificate of Analysis.Only 2 significant figures are shown here for expediency of layout. - This product has been tested according to ASTM method D 2162 for Kinematic Viscosity using Ubbelohde Master Viscometers. - The Density has been tested in accordance with ASTM method D4052 (Kinematic Viscosity x Density = Dynamic Viscosity). - Kinematic Viscosity values and Density values are traceable to the Primary Standard of pure water at 20°C as adopted by NIST. Temperature values are traceable via National Standards to the ITS-90 temperature scale.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (13 Elements) in 5% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon's Multi Element Standard for ICP; ICP-MS in 5% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Silver (Ag): 1 µg/mL (ppm). - Bismuth (Bi): 1 µg/mL (ppm). - Cobalt (Co): 1 µg/mL (ppm). - Iron (Fe): 1 µg/mL (ppm). - Aluminium (Al): 2.5 µg/mL (ppm). - Calcium (Ca): 2.5 µg/mL (ppm). - Nickel (Ni): 2.5 µg/mL (ppm). - Selenium (Se): 2.5 µg/mL (ppm). - Zinc (Zn): 2.5 µg/mL (ppm). - Cadmium (Cd): 5 µg/mL (ppm). - Copper (Cu): 5 µg/mL (ppm). - Magnesium (Mg): 5 µg/mL (ppm). - Lead (Pb): 2500 µg/mL (ppm).Color and Shape:LiquidReagecon Beryllium Standard for Atomic Absorption (AAS) 1000 µg/mL (1000 ppm) in 1M Hydrochloric Acid (HCl)
Reagecon's Beryllium Standard for Atomic Absorption (AAS) 1000 µg/mL in 1M Hydrochloric Acid (HCl) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:Liquid

