
Physicochemical Standards
Physicochemical standards are essential reference materials used to ensure the accuracy and reliability of various analytical measurements in scientific research and industrial applications. This category includes a wide range of standards such as conductivity standards, electrochemistry standards, and ICP-OES/ICP-MS standards and reagents, which are critical for precise elemental analysis and conductivity measurements. pH buffer solutions and total organic/inorganic carbon reagents are vital for maintaining pH levels and measuring carbon content in samples. Standards from European Pharmacopoeia (EP), United States Pharmacopoeia (USP), and other pharmacopoeias provide benchmarks for pharmaceutical quality control. Additional standards like turbidity, density, refractometry, and viscosity standards ensure accurate physical property measurements. Specialized standards, such as those for wine, dairy, and petrochemical industries, support quality control and regulatory compliance in specific sectors. These physicochemical standards play a crucial role in ensuring the validity and reproducibility of experimental results, supporting a wide range of applications from environmental monitoring to pharmaceutical testing and materials science.
Subcategories of "Physicochemical Standards"
- Colour Standards(74 products)
- Cryoscope Standards(10 products)
- Density Standards(107 products)
- Melting Point Standards(16 products)
- Osmolality Standards(27 products)
- Refractive Index Standards(96 products)
- Turbidity Standards(137 products)
- Viscosity Standards(75 products)
Found 3970 products of "Physicochemical Standards"
Sort by
The purity filter is not visible because current products do not have associated purity data for filtering.
Reagecon Total Base Number (TBN) Titration Solvent 2:1 Chlorobenzene and Glacial Acetic Acid for ASTM D2896
CAS:Reagecon’s Total Base Number (TBN) Titration Solvent 2:1 Chlorobenzene and Glacial Acetic Acid for ASTM D2896 is used by dissolving the sample in this solution and titrating potentiometrically with a solution of perchloric acid in glacial acetic acid. The test method is used for both new and used petroleum products that may contain basic constituents that may be present as additives. The test may also be used as a measure of lubricant degradation, but any condemning limits based on the test must be established on an individual basis.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (32 Elements) in 2-5% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Silver (Ag): 100 µg/mL (ppm). - Aluminium (Al): 100 µg/mL (ppm). - Barium (Ba): 100 µg/mL (ppm). - Bismuth (Bi): 100 µg/mL (ppm). - Calcium (Ca): 100 µg/mL (ppm). - Cadmium (Cd): 100 µg/mL (ppm). - Cobalt (Co): 100 µg/mL (ppm). - Chromium (Cr): 100 µg/mL (ppm). - Copper (Cu): 100 µg/mL (ppm). - Iron (Fe): 100 µg/mL (ppm). - Gallium (Ga): 100 µg/mL (ppm). - Germanium (Ge): 100 µg/mL (ppm). - Indium (In): 100 µg/mL (ppm). - Potassium (K): 100 µg/mL (ppm). - Lithium (Li): 100 µg/mL (ppm). - Magnesium (Mg): 100 µg/mL (ppm). - Manganese (Mn): 100 µg/mL (ppm). - Molybdenum (Mo): 100 µg/mL (ppm). - Sodium (Na): 100 µg/mL (ppm). - Niobium (Nb): 100 µg/mL (ppm). - Nickel (Ni): 100 µg/mL (ppm). - Phosphorus (P): 100 µg/mL (ppm). - Lead (Pb): 100 µg/mL (ppm). - Rhenium (Re): 100 µg/mL (ppm). - Antimony (Sb): 100 µg/mL (ppm). - Silicon (Si): 100 µg/mL (ppm). - Tin (Sn): 100 µg/mL (ppm). - Tantalum (Ta): 100 µg/mL (ppm). - Titanium (Ti): 100 µg/mL (ppm). - Vanadium (V): 100 µg/mL (ppm). - Tungsten (W): 100 µg/mL (ppm). - Zinc (Zn): 100 µg/mL (ppm).Color and Shape:LiquidReagecon Lead Standard for Ion Chromatography (IC) 0.1 mg/mL (100 ppm) in 0.005% Nitric Acid (HNO₃)
Reagecon's Lead Standard for Ion Chromatography (IC) 0.1 mg/mL (100 ppm) in 0.005% HNO₃ is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Clinical Standard Sodium 120mmol/l and Potassium 2 mmol/l for Flame Photometry
Reagecon's Sodium 120mmol/l and Potassium 2 mmol/l Standard for Flame Photometry is manufactured from ultra-pure salts. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2% for each cation. The results are reported in mg/L on the basis of weight. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Nitric Acid 5% w/v Analytical Volumetric Solution (AVL)
Reagecon's Nitric Acid 5% w/v Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon pH 8.50 Phosphate Buffer Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.3)
Reagecon’s pH 8.5 Phosphate Buffer Solution is specified for use in individual European Pharmacopoeia (EP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable; has guaranteed stability throughout its entire shelf life; even after opening the bottle. - NIST traceableColor and Shape:LiquidReagecon Barium Hydroxide Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Barium Hydroxide Solution is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include use in the identification reactions of ions and functional groups (2.3.1) and used as a reagent in the performance of tests outlined in several EP monographs. - NIST traceable - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon pH 7.41 Buffer Solution at 25°C according to European Pharmacopoeia (EP)
Reagecon's pH Buffer Solution at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable; has guaranteed stability throughout its entire shelf life; even after opening the bottle. The product is developed; formulated and specified in accordance with EP requirements. - NIST traceableColor and Shape:LiquidReagecon Acetate Buffer pH 4.5 Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP) Concentrate
Reagecon's Acetate Buffer pH 4.5 Dissolution Media Concentrate is presented in concentrate form. This concentrate measures 961.5ml in volume in each bottle and the contents of each bottle can be diluted to produce 25L of working solution in water. This diluted volume is the working Dissolution Medium. The product is prepared and when diluted can be used in accordance with relevant pharmacopoeia requirements. - This product is presented as a concentrate in order to facilitate easy shipping, storage and handling. - The pack contains 6 bottles, each of which has a volume of 961.5ml of solution, each 961.5ml bottle is diluted to give 25L of ready to use Dissolution Medium.Color and Shape:LiquidReagecon BY4 Colour Reference Solution according to European Pharmacopoeia (EP)
Reagecon’s BY4 Colour Reference Solution is formulated as a reference solution for the examination of the degree of colouration of liquids in accordance with the European Pharmacopoeia Chapter 2.2.2. This product is produced by combining Reagecon Primary Colour Solutions. - Concentration verified using a high performance spectrophotometerColor and Shape:LiquidReagecon Carbon Dioxide Standard (CO₂) 4g/l
Reagecon’s Carbon Dioxide Standard (CO₂) 1 g/l is one of a series of standards used to calibrate and control the Corning 965D Carbon Dioxide Analyser. Use of this instrument is one of a number of approved techniques available for the determination of CO₂ in beer and other carbonated beverages. This instrument was subsequently marketed by Mettler Toledo as the model M965D CO₂ Analyser. - This product is produced using raw materials of a very high purity and specification. The product is tested titrimetrically using Reagecon’s in house method TPATB against Hydrochloric Acid, Analytical Volumetric Standard solution. This standard is directly traceable to NIST Standard Reference Material 723e - tris(hydroxymethyl)aminomethane. A detailed Certificate of Analysis is issued with each batch manufactured.Color and Shape:LiquidReagecon Density Standard Quality Range 0.8292 g/mL at 60°C
This Reagecon Density Standard Quality Range 0.8292 g/mL at 60°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%Color and Shape:LiquidReagecon Ion Chromatography (IC) Multi Element Anion Standard (3 Elements) in Water (H₂O)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Sulphate (SO₄²): 1000 µg/mL (ppm). - Fluoride (F⁻): 1000 µg/mL (ppm). - Chloride (Cl⁻): 1000 µg/mL (ppm).Color and Shape:LiquidReagecon Iodine 0.1M (0.2N) Analytical Volumetric Solution (AVL)
Reagecon's Iodine 0.1M (0.2N) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for oxidation/reduction titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties. Oxidation/reduction titrations depend on changes in the electropotential of the oxidation reduction system and always involves a reaction between an oxidising and reducing pair. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Sodium Carbonate Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Sodium Carbonate Solution is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include use in the identification reactions of ions and functional groups (2.3.1) and used as a reagent in the performance of tests outlined in several EP monographs. - NIST traceable - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Refractive Index Standard (Stabilised Sucrose) 1.35568 nD units at 20°C
Reagecon's Refractive Index Standard (Stabilised Sucrose) 1.35568 nD units at 20°C is a high quality product, with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Refractive Index determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer, manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation for the test method used to certify this product. - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.00014 nD units. It is stable for one year; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.00014 nD units) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon Sodium Standard for Atomic Absorption (AAS) 10 µg/mL (10 ppm) in 0.5M Nitric Acid (HNO₃)
Reagecon's Sodium Standard for Atomic Absorption (AAS) 10 µg/mL in 0.5M Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:Liquid

