
Physicochemical Standards
Physicochemical standards are essential reference materials used to ensure the accuracy and reliability of various analytical measurements in scientific research and industrial applications. This category includes a wide range of standards such as conductivity standards, electrochemistry standards, and ICP-OES/ICP-MS standards and reagents, which are critical for precise elemental analysis and conductivity measurements. pH buffer solutions and total organic/inorganic carbon reagents are vital for maintaining pH levels and measuring carbon content in samples. Standards from European Pharmacopoeia (EP), United States Pharmacopoeia (USP), and other pharmacopoeias provide benchmarks for pharmaceutical quality control. Additional standards like turbidity, density, refractometry, and viscosity standards ensure accurate physical property measurements. Specialized standards, such as those for wine, dairy, and petrochemical industries, support quality control and regulatory compliance in specific sectors. These physicochemical standards play a crucial role in ensuring the validity and reproducibility of experimental results, supporting a wide range of applications from environmental monitoring to pharmaceutical testing and materials science.
Subcategories of "Physicochemical Standards"
- Colour Standards(74 products)
- Cryoscope Standards(10 products)
- Density Standards(107 products)
- Melting Point Standards(16 products)
- Osmolality Standards(27 products)
- Refractive Index Standards(96 products)
- Turbidity Standards(137 products)
- Viscosity Standards(75 products)
Found 3970 products of "Physicochemical Standards"
Sort by
The purity filter is not visible because current products do not have associated purity data for filtering.
Reagecon Uranium Standard for Atomic Absorption (AAS) 10,000 µg/mL (10,000 ppm) in 1M Nitric Acid (HNO₃)
Reagecon's Uranium Standard for Atomic Absorption (AAS) 10;000 µg/mL in 1M Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Sodium Hypochlorite 0.5% w/v Cleaning Solution
Reagecon's Sodium Hypochlorite 0.5% w/v Cleaning Solution is a high quality antimicrobial (bactericidal/viricidal) disinfectant presented in a convenient pack size. The product is highly effective in sanitising laboratory, production and processing areas and equipment (not stainless steel).Color and Shape:LiquidReagecon Clinical Standard Cesium 1.5 mmol/L for Flame Photometry
Reagecon's Cesium 1.5 mmol/L Standard for Flame Photometry is manufactured from ultra-pure salts. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2% for each cation. The results are reported in mg/L on the basis of weight. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Sodium Hydroxide 0.1M (0.1N) Analytical Volumetric Solution (AVL)
Reagecon's Sodium Hydroxide 0.1M (0.1N) Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Diphenylamine R1 Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Diphenylamine R1 Solution is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include the preparation of other reagents (4.1.1) and used as a reagent in the performance of tests outlined in several EP monographs. - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Carbon Dioxide Standard (CO₂) Release Agent
Reagecon’s Carbon Dioxide (CO₂) Release Agent is used as an acidic CO₂ release agent during the measurement of CO₂ using the Corning 965D Carbon Dioxide Analyser. Use of this instrument is one of a number of approved techniques available for the determination of CO₂, in beer and other carbonated beverages. This instrument was subsequently marketed by Mettler Toledo as the model M965D CO₂ Analyser. - This product is produced using raw materials of a very high purity and specification. The product is tested using Reagecon Test Method TPATA and the result expressed in Molar Acidity, specification 2.0 – 2.2M acidity. A Certificate of Conformity is issued with each batch.Color and Shape:LiquidReagecon Lead Nitrate 0.05M according to Chinese Pharmacopoeia (ChP)
Reagecon's Lead Nitrate 0.05M is a fully factorised, high purity, stable product, developed and tested for titrations. This is an Analytical Volumetric Solution, also called titrant, standard titrant or standard solution. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations also called potentiometric titration, to determine the end points by detection of any of several properties as detailed in several ChP monographs. - NIST Traceable - Titration is a rapid, economical and versatile analytical tool. This Reagecon Analytical Volumetric Solution is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stochiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Chemical Oxygen Demand (COD) Vials 0-15,000 mg/L
Reagecon's Chemical Oxygen Demand (COD) vials 0-15,000 mg/l can be used in conjunction with the Hach®, Aqualytic PC Spectro® and Aqualytic PC Compact Vario® Spectrophotometers that accept 16mm vials. - Ready to use in 16mm diameter vials. - Compatible with all dedicated spectrophotometer brands. - Use in the same way as instrument manufacturer’s vials. - See More on Reagecon's Chemical Oxygen Demand (COD) Vials COD Vials - Product Instruction-Information Sheet - It is considered best practice to always include a COD control standard when testing samples, with the value of the control standard close to the expected COD value for your samples. Reagecon supply a wide range of Chemical Oxygen Demand (COD) Standards which can be used for this purpose.Color and Shape:LiquidReagecon pH 10.00 Colour Coded Buffer Solution at 20°C in Twin Neck
Reagecon's pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Spectrophotometry Bandwidth Resolution Standard Toluene in Hexane (Ph. Eur) Ratio of 268.7nm Peak to 266.8nm Trough
CAS:Reagecon's Spectrophotometry Bandwidth Resolution Standard Toluene in Hexane (Ph. Eur) Ratio of 268.7nm Peak to 266.8nm Trough produces a series of peaks and troughs over a very narrow change of wavelength. It enables a plot to be plotted that displays a maximum trough at an absorbance of 0.15A.Color and Shape:LiquidReagecon Colour Reference Solution No.2 Yellow according to Chinese Pharmacopoeia (ChP)
Reagecon's Colour Reference Solution No.2 Yellow is formulated as a reference solution for the examination of the degree of colouration of liquids in accordance with the Chinese Pharmacopoeia. This product is produced by combining Reagecon Primary Colour Solutions. - This Reference Colour Solution is a ready to use coloration standard presented in high quality, tamper evident bottles for use as a calibration and/or quality control standard. It is prepared by combining Reagecon Primary Colour Solutions. - Manufactured gravimetrically according to Chinese Pharmacopoeia guidelines. - Concentration verified using a high performance spectrophotometer.Color and Shape:LiquidReagecon Ammonia Dilute R1 according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Ammonia Dilute R1 is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include the preparation of other reagents (4.1.1), a component of buffer solutions (4.1.3) and used as a reagent in the performance of tests outlined in several EP monographs. - NIST traceable - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Ion Chromatography (IC) Multi Element Anion Standard (5 Elements) in Water (H₂O)
Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Fluoride (F⁻): 20 µg/mL (ppm). - Chloride (Cl⁻): 30 µg/mL (ppm). - Nitrate (NO₃): 100 µg/mL (ppm). - Phosphate (PO₄³): 150 µg/mL (ppm). - Sulphate (SO₄²): 150 µg/mL (ppm).Color and Shape:LiquidReagecon Iron Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)
Reagecon's Iron Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Barium Chloride TS/RS Solution according to United States Pharmacopoeia (USP)
Reagecon's Barium Chloride TS/RS Solution according to United States Pharmacopoeia (USP) is specified for use in individual United States Pharmacopoeia (USP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03); is NIST traceable and has guaranteed stability throughout its entire shelf life; even after opening the bottle.Color and Shape:LiquidReagecon Mercury Standard for Atomic Absorption (AAS) 1000 µg/mL (1000 ppm) in 0.5M Nitric Acid (HNO₃)
Reagecon's Mercury Standard for Atomic Absorption (AAS) 1000 µg/mL in 0.5M Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon 30,000 µS/cm Conductivity Standard at 25°C (CDt)
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 1 NTU Turbiform™ Stabilised Formazin Turbidity Standard
This standard is an aqueous suspension of a formazin type product that carries all of the advantages of formazin but eliminates its shortcomings. It is stable; safe; EPA approved and accurate. - Reagecon have developed a proprietary synthetic process that produces a family of products called Turbiform™. These products combine most of the positive attributes of the formazin and AMCO APEA-1 range of standards already available from Reagecon; whilst eliminating most of the shortcomings. Most importantly; this process does not interfere adversely with the status of formazin as the recognised primary standard. - Product exhibits a wide range of particle sizes; shapes and slopes (similar to formazin) mean diameter 3 µm with distribution of between 1 and 20 microns; which are similar to the particle size and distribution found in most sample types. - This product can be used to calibrate; control; validate or qualify; almost any make or model of Turbidity measuring instrument. - Traceable to NIST reference material 1690 and 1691 - Can be used to calibrate; control; validate or qualify almost any make or model of instrumentColor and Shape:LiquidReagecon Density Standard Quality Range 1.0005 g/mL at 20°C
This Reagecon Density Standard Quality Range 1.0005 g/mL at 20°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%Color and Shape:Liquid

