
Physicochemical Standards
Physicochemical standards are essential reference materials used to ensure the accuracy and reliability of various analytical measurements in scientific research and industrial applications. This category includes a wide range of standards such as conductivity standards, electrochemistry standards, and ICP-OES/ICP-MS standards and reagents, which are critical for precise elemental analysis and conductivity measurements. pH buffer solutions and total organic/inorganic carbon reagents are vital for maintaining pH levels and measuring carbon content in samples. Standards from European Pharmacopoeia (EP), United States Pharmacopoeia (USP), and other pharmacopoeias provide benchmarks for pharmaceutical quality control. Additional standards like turbidity, density, refractometry, and viscosity standards ensure accurate physical property measurements. Specialized standards, such as those for wine, dairy, and petrochemical industries, support quality control and regulatory compliance in specific sectors. These physicochemical standards play a crucial role in ensuring the validity and reproducibility of experimental results, supporting a wide range of applications from environmental monitoring to pharmaceutical testing and materials science.
Subcategories of "Physicochemical Standards"
- Colour Standards(74 products)
- Cryoscope Standards(10 products)
- Density Standards(107 products)
- Melting Point Standards(16 products)
- Osmolality Standards(27 products)
- Refractive Index Standards(96 products)
- Turbidity Standards(137 products)
- Viscosity Standards(75 products)
Found 3970 products of "Physicochemical Standards"
Sort by
The purity filter is not visible because current products do not have associated purity data for filtering.
Reagecon Ion Chromatography (IC) Multi Element Anion Standard (6 Elements) in Water (H₂O)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Chlorine (Cl): 20 µg/mL (ppm). - Fluorine (F): 1 µg/mL (ppm). - Nitrate (NO₃): 5 µg/mL (ppm). - Nitrite (NO₂): 1 µg/mL (ppm). - Phosphate (PO₄³): 10 µg/mL (ppm). - Sulphate (SO₄²): 50 µg/mL (ppm).Color and Shape:LiquidReagecon Phosphomolybdotungstic Reagent according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Phosphomolybdotungstic Reagent is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include the preparation of other reagents (4.1.1) and used as a reagent in the performance of tests outlined in several EP monographs. - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Mercuric Chloride TS Solution according to United States Pharmacopoeia (USP)
CAS:Reagecon's Mercuric Chloride TS Solution according to United States Pharmacopoeia (USP) is specified for use in individual United States Pharmacopoeia (USP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03); is NIST traceable and has guaranteed stability throughout its entire shelf life; even after opening the bottle.Color and Shape:LiquidReagecon Sodium Hydroxide 10M (10N) Analytical Volumetric Solution (AVL)
Reagecon's Sodium Hydroxide 10M (10N) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for acid/base titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties. Acid/base titrations, also called neutralisation titrations, are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Saybolt +15 Colour Standard
Reagecon's Saybolt +15 Colour Standard can be used to calibrate, control, qualify or validate colour measurement instruments. This includes ASTM specified methods D 156 and D 6045. The standard is particularly suited for colour grading light coloured petroleum products.Color and Shape:LiquidReagecon 20% Sucrose in Water (Brix) ISO 17034 Certified Reference Material
Reagecon’s 20% Sucrose in Water (Brix) is a Certified Reference Material (CRM). The product is manufactured and certified in accordance with the requirements of ISO 17034 (A2LA Ref: 6739.01) and can be used on any make or model of refractometer. This product is used primarily either as a calibrant or analytical control solution in Refractive Index based methods of Brix value determinations; it can also be used to validate appropriate test methods or qualify a refractometer for use in a regulated industry. The product has a shelf life of 20 weeks; is manufactured in accordance with ICUMSA guidelines and is presented in a convenient high quality dropper bottle. - The product measurement uncertainty is computated on a batch to batch basis; but is guaranteed to never exceed ± 0.15 °Brix. ISO 17034 accreditation (A2LA Ref: 6739.01) requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control. This product is certified gravimetrically on a mass fraction basis. Both solute and solvent are weighed on balances calibrated by Reagecon’s engineers using OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances.Color and Shape:LiquidReagecon Density Standard Quality Range 0.7111 g/mL at 25°C
CAS:This Reagecon Density Standard Quality Range 0.7111 g/mL at 25°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%Color and Shape:LiquidReagecon Calcium Standard for Ion Chromatography (IC) 0.2 mg/mL (200 ppm) in Water (H₂O)
Reagecon's Calcium Standard for Ion Chromatography (IC) 0.2 mg/mL (200 ppm) in H₂O is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon 124 mV Redox Oxidation/Reduction (ORP) Standard at 25°C
This Reagecon 124 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 124 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (10 Elements) in 2-5% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Aluminium (Al): 1000 µg/mL (ppm). - Boron (B): 1000 µg/mL (ppm). - Cadmium (Cd): 1000 µg/mL (ppm). - Chromium (Cr): 1000 µg/mL (ppm). - Copper (Cu): 1000 µg/mL (ppm). - Iron (Fe): 1000 µg/mL (ppm). - Manganese (Mn): 1000 µg/mL (ppm). - Nickel (Ni): 1000 µg/mL (ppm). - Lead (Pb): 1000 µg/mL (ppm). - Zinc (Zn): 1000 µg/mL (ppm).Color and Shape:LiquidReagecon Density Standard Premium Range 1.0005 g/mL at 20°C
This Reagecon Density Standard Premium Range 1.0005 g/mL at 20°C is manufactured and tested in accordance with ASTM D1480-12 for testing of density or relative density (specific and API gravity). It is tested by Bingham Pycnometry and can be used as a calibration or control standard for density measurement by pycnometer, vibrational, or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using Bingham Pycnometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 Accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). The density of the product is established and tested using high performance calibrated reference pycnometers. - High accuracy (± 0.00077 g/ml) - Tested using a fundamental measurement technique (Bingham Pycnometer)Color and Shape:LiquidReagecon Ion Chromatography (IC) Multi Element Cation Standard (6 Elements) in Water (H₂O)
Reagecon's Ion Chromatography (IC) Multi Element Cation Standard (6 Elements) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Lithium (Li): 50 µg/mL (ppm). - Sodium (Na): 200 µg/mL (ppm). - Ammonium (NH₄): 250 µg/mL (ppm). - Magnesium (Mg): 250 µg/mL (ppm). - Calcium (Ca): 500 µg/mL (ppm). - Potassium (K): 500 µg/mL (ppm).Color and Shape:LiquidReagecon Manganese Standard for Atomic Absorption (AAS) 1000 µg/mL (1000 ppm) in 2% Nitric Acid (HNO₃)
Reagecon's Manganese Standard for Atomic Absorption (AAS) 1000 µg/mL in 2% Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Total Base Number (TBN) Standard 1.0 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix
Reagecon Total Base Number (TBN) Standard 1.0 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This high quality standard can be used to calibrate; control or validate the methodology or equipment used to perform TBN testing according to ASTM Method D2896. - Produced in accordance with ASTM D2896. - Test method D2896 is used for both new and used petroleum products that may contain basic constituents that may be present as additives. - The test method D2896 may also be used as a measure of lubricant degradation; but any condemning limits based on the test must be established on an individual basis. - Standards are traceable to NIST. - The method has a very low uncertainty of measurement. - Stability is proven (either opened or unopened) for the shelf life of this product. - This Standard forms part of the linearity set of TBN Standards that range in value from 1.0 mg/g KOH in a synthetic base oil up to 70 mg/g KOH. - Consistency of product - Independent; Traceable; Certified.Color and Shape:SolidReagecon ICP, ICP-MS Multi Element Standard (3 Elements) in 2% Nitric Acid (HNO₃), ICH Q3D Oral Class 2B
Reagecon’s Multi Element Standard for ICP; ICP-MS in 2% HNO₃ is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Selenium (Se): 150 µg/mL (ppm). - Silver (Ag): 150 µg/mL (ppm). - Thallium (Tl): 8 µg/mL (ppm).Color and Shape:LiquidReagecon Potassium Phosphate pH 6.8 Dissolution Media in accordance to United States (USP) and European Pharmacopoeias (EP) Concentrate
Reagecon's Potassium Phosphate pH 6.8 Dissolution Media Concentrate is presented in concentrate form. This concentrate measures 384ml in volume in each bottle and the contents of each bottle can be diluted to produce 10L of working solution in water. This diluted volume is the working Dissolution Medium. The product is prepared and when diluted can be used in accordance with relevant pharmacopoeia requirements. - This product is presented as a concentrate in order to facilitate easy shipping, storage and handling. - The pack contains 12 bottles, each of which has a volume of 384ml of solution, each 384ml bottle is diluted to give 10L of ready to use Dissolution Medium.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (15 Elements) in 2-5% Nitric Acid (HNO₃) and trace Hydrofluoric Acid (HF)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon's Multi Element Standard for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) and trace Hydrofluoric Acid (HF) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Molybdenum (Mo): 10 µg/mL (ppm). - Aluminium (Al): 50 µg/mL (ppm). - Cadmium (Cd): 50 µg/mL (ppm). - Cobalt (Co): 50 µg/mL (ppm). - Copper (Cu): 50 µg/mL (ppm). - Chromium (Cr): 50 µg/mL (ppm). - Iron (Fe): 50 µg/mL (ppm). - Manganese (Mn): 50 µg/mL (ppm). - Nickel (Ni): 50 µg/mL (ppm). - Lead (Pb): 50 µg/mL (ppm). - Silicon (Si): 50 µg/mL (ppm). - Vanadium (V): 50 µg/mL (ppm). - Tungsten (W): 50 µg/mL (ppm). - Zinc (Zn): 50 µg/mL (ppm).Color and Shape:LiquidReagecon ASTM Colour Standard A7
Reagecon’s ASTM Colour Standard A7 can be used to calibrate, control, qualify or validate colour measurement instruments. This includes ASTM specified methods D1500, D6045 for petrochemical products and ISO 2049 and IP 196 for other liquids.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (10 Elements) in 2-5% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Arsenic (As): 1000 µg/mL (ppm). - Cadmium (Cd): 1000 µg/mL (ppm). - Chromium (Cr): 1000 µg/mL (ppm). - Copper (Cu): 1000 µg/mL (ppm). - Iron (Fe): 1000 µg/mL (ppm). - Mercury (Hg): 1000 µg/mL (ppm). - Manganese (Mn): 1000 µg/mL (ppm). - Nickel (Ni): 1000 µg/mL (ppm). - Lead (Pb): 1000 µg/mL (ppm). - Zinc (Zn): 1000 µg/mL (ppm).Color and Shape:LiquidReagecon Density Standard Quality Range 0.9060 g/mL at 25°C
This Reagecon Density Standard Quality Range 0.9060 g/mL at 25°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%Color and Shape:Liquid
