CymitQuimica logo
Physicochemical Standards

Physicochemical Standards

Physicochemical standards are essential reference materials used to ensure the accuracy and reliability of various analytical measurements in scientific research and industrial applications. This category includes a wide range of standards such as conductivity standards, electrochemistry standards, and ICP-OES/ICP-MS standards and reagents, which are critical for precise elemental analysis and conductivity measurements. pH buffer solutions and total organic/inorganic carbon reagents are vital for maintaining pH levels and measuring carbon content in samples. Standards from European Pharmacopoeia (EP), United States Pharmacopoeia (USP), and other pharmacopoeias provide benchmarks for pharmaceutical quality control. Additional standards like turbidity, density, refractometry, and viscosity standards ensure accurate physical property measurements. Specialized standards, such as those for wine, dairy, and petrochemical industries, support quality control and regulatory compliance in specific sectors. These physicochemical standards play a crucial role in ensuring the validity and reproducibility of experimental results, supporting a wide range of applications from environmental monitoring to pharmaceutical testing and materials science.

Subcategories of "Physicochemical Standards"

Found 3970 products of "Physicochemical Standards"

Sort by

The purity filter is not visible because current products do not have associated purity data for filtering.
products per page.
  • Reagecon Chromium (6+) Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in Water (H₂O)


    Reagecon's Chromium (6+) Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in Water (H₂O) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.
    Color and Shape:Liquid

    Ref: 07-PCR62A7

    100ml
    108.00€
  • Reagecon Methyl Red Indicator 0.05% Solution according to Chinese Pharmacopoeia (ChP)


    Reagecon's Methyl Red Indicator 0.05% Solution is a high quality Indicator Solution produced from the highest quality raw materials and manufactured and tested under rigorous conditions. During manual titrations; indicator, titrant or analyte change colour and this colour change is by far the most important method of end point detection, in such titrations. A high quality indicator solution such as Reagecon’s, facilitates end point detection, in a clear and unambiguous manner and is an imperative for accurate manual titrimetry.
    Color and Shape:Liquid

    Ref: 07-CPMETRSOL01

    100ml
    58.00€
  • Reagecon Deionised Water (25L)


    Reagecon’s Deionised Water is a high quality pure water product, presented in a convenient pack size. The product can be used as a matrix for a variety of solutes or as a cleaning/sanitisation solution.
    Color and Shape:Liquid

    Ref: 07-Y0018

    25l
    84.00€
  • Reagecon Silver Nitrate 0.1M (0.1N) Analytical Volumetric Solution (AVL)


    Reagecon's Silver Nitrate 0.1M (0.1N) Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for precipitation (argentometric) titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Precipitation titrimetry is based on reactions that yield compounds of limited solubility. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.
    Color and Shape:Liquid

    Ref: 07-N20100H

    500ml
    73.00€
  • Reagecon Refractive Index Standard (Stabilised Sucrose) 1.35171 nD units at 20°C


    Reagecon's Refractive Index Standard (Stabilised Sucrose) 1.35171 nD units at 20°C is a high quality product, with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Refractive Index determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer, manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation for the test method used to certify this product. - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.00014 nD units. It is stable for one year; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.00014 nD units) - Tested using a state of the art Refractometer
    Color and Shape:Liquid

    Ref: 07-RIBS125S6

    6x15ml
    486.00€
  • Reagecon Clinical Standard Sodium 60 mmol/L and Potassium 25 mmol/L for Flame Photometry


    Reagecon's Sodium 60 mmol/L and Potassium 25 mmol/L Standard for Flame Photometry is manufactured from ultra-pure salts. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2% for each cation. The results are reported in mg/L on the basis of weight. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.
    Color and Shape:Liquid

    Ref: 07-FCNK16

    500ml
    113.00€
  • Reagecon 100 ppm Chemical Oxygen Demand Standard


    This highly accurate 100 ppm Chemical Oxygen Demand (COD) Calibration Standard, can be used to calibrate, control, verify or validate all COD Test Methods. The product yields an accurate test result of 100 ppm. Achieving this correct result increases significantly the confidence of the analyst in the correct COD reading of the sample. - Reagecon’s COD Standards are ideal for use as Control Standards to verify that correct analysis for COD has taken place. Achieving an acceptable result for the Control Standard will improve confidence in sample readings for this important environmental parameter. - Used as a Control Standard; or for Validation or Qualification. - Directly traceable to NIST standard reference materials. - Run Control with each set of samples. - Prepare and analyse in exactly the same way as samples. - Manufactured to exacting specifications with an extended shelf life and stability. - Proven compliance with EPA. - Compatible with any instrument.
    Color and Shape:Liquid

    Ref: 07-COD100

    500ml
    130.00€
  • Reagecon ICP, ICP-MS Multi Element Standard (18 Elements) in 2% Nitric Acid (HNO₃)


    Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2% HNO₃ is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Arsenic (As): 10 µg/mL (ppm). - Cadmium (Cd): 10 µg/mL (ppm). - Selenium (Se): 10 µg/mL (ppm). - Chromium (Cr): 10 µg/mL (ppm). - Copper (Cu): 10 µg/mL (ppm). - Nickel (Ni): 100 µg/mL (ppm). - Lead (Pb): 100 µg/mL (ppm). - Zinc (Zn): 100 µg/mL (ppm). - Barium (Ba): 100 µg/mL (ppm). - Aluminium (Al): 100 µg/mL (ppm). - Boron (B): 100 µg/mL (ppm). - Beryllium (Be): 100 µg/mL (ppm). - Cobalt (Co): 100 µg/mL (ppm). - Iron (Fe): 100 µg/mL (ppm). - Manganese (Mn): 100 µg/mL (ppm). - Strontium (Sr): 100 µg/mL (ppm). - Thallium (Tl): 100 µg/mL (ppm). - Vanadium (V): 100 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-ICP-MIX1-CYM

    100ml
    622.00€
  • Reagecon System Suitability Set to USP for Total Organic (TOC) suitable for use with Sievers 900/M9 Analysers


    Reagecon's System Suitability Set to USP for Total Organic (TOC) is a product of extremely high specification and purity. The product is produced from ultra pure raw materials including water that is prepared by a special proprietary process. The product is presented in vials that are manufactured, cleaned and leached, by a special proprietary process specifically for the product. - The products RTOCRs and RTOCRss from the table above are prepared gravimetrically on a weight/volume basis to a specification of ± 2%. Reagecon holds IEC/ISO 17025 accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). Products are tested using a high performance calibrated Total Organic Carbon Analyser (TOC Instrument); RTOCRs and RTOCRss are tested within the scope of Reagecon’s ISO 17025 accredited test method (A2LA Ref: 6739.03) and RTOCW is not tested within the scope of the accredited test method. Item No - Description | Qty: - RTOCRs-TOC Standard USP Standard Sucrose Solution Rs (0.5mg/L C): 1. - RTOCRss-TOC Standard USP System Suitability Solution 1 4-Benzoquinone (0.5mg/L C): 1. - RTOCW-TOC Standard USP Reagent Water Rw: 1.
    Color and Shape:Liquid

    Ref: 07-RTOCUSP1

    3x40ml
    275.00€
  • Reagecon Sodium Hydroxide Strong Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)


    Reagecon Sodium Hydroxide Strong Solution is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications.  These include the preparation of other reagents (4.1.1), a component of buffer solutions (4.1.3), use in identification reactions of ions and functional groups (2.3.1) and used as a reagent in the performance of tests outlined in several EP monographs. - NIST traceable - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.
    Color and Shape:Liquid

    Ref: 07-1081404

    1l
    157.00€
  • Reagecon Methyl Orange Indicator conforms to United States Pharmacopoeia (USP)


    Reagecon's Methyl Orange Indicator Solution is a high quality Indicator Solution produced from the highest quality raw materials and manufactured and tested under rigorous conditions. For manual titrations; indicator, titrant or analyte change colour and this colour change is by far the most important method of end point detection, in such titrations. A high quality indicator solution such as Reagecon's’s facilitates end point detection, in a clear and unambiguous manner and is an imperative for accurate manual titrimetry.
    Color and Shape:Liquid

    Ref: 07-USP3401

    100ml
    49.00€
  • Reagecon Cadmium Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)


    Reagecon's Cadmium Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.
    Color and Shape:Liquid

    Ref: 07-PCD2B2

    250ml
    176.00€
  • Reagecon Density Standard Quality Range 0.9514 g/mL at 15°C


    This Reagecon Density Standard Quality Range 0.9514 g/mL at 15°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%
    Color and Shape:Liquid

    Ref: 07-DEN15130

    100ml
    128.00€
  • Reagecon N18000 Kinematic Viscosity, Dynamic Viscosity and Density Standard


    Reagecon’s N18000 Kinematic Viscosity, Dynamic Viscosity and Density Standard can be used to calibrate, control or validate all types of viscometers including capillary, flow cup, rotational, falling ball, falling/rising object, stabinger and vibrational viscometers.This Viscosity Standard and all Reagecon Viscosity Standards are reported to 4 significant figures on their Certificate of Analysis.Only 2 significant figures are shown here for expediency of layout.   - This product has been tested according to ASTM method D 2162 for Kinematic Viscosity using Ubbelohde Master Viscometers. - The Density has been tested in accordance with ASTM method D4052 (Kinematic Viscosity x Density = Dynamic Viscosity). - Kinematic Viscosity values and Density values are traceable to the Primary Standard of pure water at 20°C as adopted by NIST. Temperature values are traceable via National Standards to the ITS-90 temperature scale.
    Color and Shape:Liquid

    Ref: 07-REVIS-N18000

    500ml
    131.00€
  • Reagecon pH 1.68 Buffer Solution at 25°C


    Reagecon’s pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.
    Color and Shape:Liquid

    Ref: 07-1016825

    1l
    47.00€
  • Reagecon ICP, ICP-MS Multi Element Standard (6 Elements) in 2-5% Hydrochloric Acid (HCl)


    Reagecon's Multi Element Standard for ICP; ICP-MS in 2-5% Hydrochloric Acid (HCl) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Caesium Chloride (CsCl): 1000 µg/mL (ppm). - Calcium (Ca): 3 µg/mL (ppm). - Magnesium (Mg): 2 µg/mL (ppm). - Phosphorus (P): 15 µg/mL (ppm). - Potassium (K): 20 µg/mL (ppm). - Sodium (Na): 5 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-REICPCAL6M1

    250ml
    327.00€
  • Reagecon Ion Chromatography (IC) Multi Element Anion Standard (7 Elements) in Water (H₂O)


    Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Fluoride (F⁻): 0.25 µg/mL (ppm). - Bromate (BrO₃): 0.25 µg/mL (ppm). - Nitrite (NO₂): 0.25 µg/mL (ppm). - Phosphate (PO₄³): 0.25 µg/mL (ppm). - Nitrate (NO₃): 6.25 µg/mL (ppm). - Chloride (Cl⁻): 25 µg/mL (ppm). - Sulphate (SO₄²): 50 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-REICA7MIX4A

    100ml
    112.00€
  • Reagecon Fluoride 5 ppm Ion Selective Electrode Standard


    Reagecon's Fluoride 5 ppm Ion Selective Electrode Standard can be used at suitable concentrations to calibrate or control measurements that use Ion Selective Electrodes (ISE’s) as the sensing technology. - Reagecon’s Ion Selective Electrode (ISE) Standards; diluted to a suitable concentration; are particularly suitable for use as a calibration or control material; using Ion Selective Electrodes as the sensing technology. - Accurate to ± 0.5%. - Aqueous matrix. - Directly traceable to NIST standard reference materials. - Can be used for Method Validation or Instrument Qualification. - Can also be used as a calibrant for other techniques. - Safe; compatible with all types of ISE Electrodes. - Manufactured to exacting specifications with an extended shelf life & stability; even after opening the bottle.
    Color and Shape:Liquid

    Ref: 07-ISEF0505

    500ml
    135.00€
  • Reagecon Ammonium 1000ppm as NH₄ Ion Selective Electrode Standard


    Reagecon's Ammonium 1000ppm as NH₄ Ion Selective Electrode Standard can be used at suitable concentrations to calibrate or control measurements that use Ion Selective Electrodes (ISE’s) as the sensing technology. - Reagecon’s Ion Selective Electrode (ISE) Standards; diluted to a suitable concentration; are particularly suitable for use as a calibration or control material; using Ion Selective Electrodes as the sensing technology. - Accurate to ± 0.5%. - Aqueous matrix. - Directly traceable to NIST standard reference materials. - Can be used for Method Validation or Instrument Qualification. - Can also be used as a calibrant for other techniques. - Safe; compatible with all types of ISE Electrodes. - Manufactured to exacting specifications with an extended shelf life & stability; even after opening the bottle.
    Color and Shape:Liquid

    Ref: 07-ISENH45

    500ml
    117.00€
  • Reagecon ICP, ICP-MS Multi Element Standard (8 Elements) in 2-5% Nitric Acid (HNO₃) and 1% Hydrofluoric Acid (HF)


    Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon's Multi Element Standard for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) and 1% Hydrofluoric Acid (HF) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Antimony (Sb): 100 µg/mL (ppm). - Barium (Ba): 100 µg/mL (ppm). - Beryllium (Be): 100 µg/mL (ppm). - Cobalt (Co): 100 µg/mL (ppm). - Molybdenum (Mo): 100 µg/mL (ppm). - Selenium (Se): 100 µg/mL (ppm). - Silver (Ag): 100 µg/mL (ppm). - Thallium (Tl): 100 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-REICPCAL8SD

    250ml
    370.00€