CymitQuimica logo
Physicochemical Standards

Physicochemical Standards

Physicochemical standards are essential reference materials used to ensure the accuracy and reliability of various analytical measurements in scientific research and industrial applications. This category includes a wide range of standards such as conductivity standards, electrochemistry standards, and ICP-OES/ICP-MS standards and reagents, which are critical for precise elemental analysis and conductivity measurements. pH buffer solutions and total organic/inorganic carbon reagents are vital for maintaining pH levels and measuring carbon content in samples. Standards from European Pharmacopoeia (EP), United States Pharmacopoeia (USP), and other pharmacopoeias provide benchmarks for pharmaceutical quality control. Additional standards like turbidity, density, refractometry, and viscosity standards ensure accurate physical property measurements. Specialized standards, such as those for wine, dairy, and petrochemical industries, support quality control and regulatory compliance in specific sectors. These physicochemical standards play a crucial role in ensuring the validity and reproducibility of experimental results, supporting a wide range of applications from environmental monitoring to pharmaceutical testing and materials science.

Subcategories of "Physicochemical Standards"

Found 3970 products of "Physicochemical Standards"

Sort by

The purity filter is not visible because current products do not have associated purity data for filtering.
products per page.
  • Reagecon 150 NTU Non Ratio Turbidity Standard


    Reagecon 150 NTU Non Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for non-ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - These Turbidity Standards remove the handling; stability and accuracy problems associated with traditional Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …
    Color and Shape:Liquid

    Ref: 07-CRS-150-500

    500ml
    426.00€
  • Reagecon ICP, ICP-MS Multi Element Standard (7 Elements) in 2-5% Nitric Acid (HNO₃)


    Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Arsenic (As): 100 µg/mL (ppm). - Cadmium (Cd): 100 µg/mL (ppm). - Cobalt (Co): 100 µg/mL (ppm). - Mercury (Hg): 100 µg/mL (ppm). - Nickel (Ni): 100 µg/mL (ppm). - Lead (Pb): 100 µg/mL (ppm). - Vanadium (V): 100 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-REICPCAL7AE

    100ml
    422.00€
  • Reagecon Refractive Index Standard (Solvent Based) 1.46768 nD units at 20°C

    CAS:
    Reagecon's Refractive Index Standards (Solvent Based) 1.46768 nD at 20°C is a high quality product; with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Refractive Index determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer; manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for the test method. - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.00014 nD units. It is stable for two years; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.000158 nD units) - Tested using a state of the art Refractometer
    Color and Shape:Liquid

    Ref: 07-RI0146

    15ml
    180.00€
  • Reagecon Iron (II) Sulphate 0.2M (0.2N) Analytical Volumetric Solution (AVL)


    Reagecon's Iron (II) Sulphate 0.2M (0.2N) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for oxidation/reduction titrations.  This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete.  The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties.  Oxidation/reduction titrations depend on changes in the electropotential of the oxidation reduction system and always involves a reaction between an oxidising and reducing pair. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.
    Color and Shape:Liquid

    Ref: 07-FES2021

    1l
    58.00€
  • Reagecon Density Standard Quality Range 0.8868 g/mL at 50°C


    This Reagecon Density Standard Quality Range 0.8868 g/mL at 50°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%
    Color and Shape:Liquid

    Ref: 07-DEN50120

    100ml
    128.00€
  • Reagecon S30000 Kinematic Viscosity, Dynamic Viscosity and Density Standard to 100°C


    Reagecon's S30000 Kinematic Viscosity, Dynamic Viscosity and Density Standard can be used to calibrate, control or validate all types of viscometers including capillary, flow cup, rotational, falling ball, falling/rising object, stabinger and vibrational viscometers.This Viscosity Standard and all Reagecon Viscosity Standards are reported to 4 significant figures on their Certificate of Analysis.Only 2 significant figures are shown here for expediency of layout.   - This product has been tested according to ASTM method D 2162 for Kinematic Viscosity using Ubbelohde Master Viscometers. - The Density has been tested in accordance with ASTM method D4052 (Kinematic Viscosity x Density = Dynamic Viscosity). - Kinematic Viscosity values and Density values are traceable to the Primary Standard of pure water at 20°C as adopted by NIST. Temperature values are traceable via National Standards to the ITS-90 temperature scale.
    Color and Shape:Liquid

    Ref: 07-REVISC-S30000

    500ml
    142.00€
  • Reagecon 3M Potassium Chloride Electrode Filling Solution Saturated with Silver Chloride (Electrolyte)


    Concentrated or saturated Potassium Chloride (KCl) is the optimal electrolyte and filling solution for potentiometric titrations, direct pH measurement, redox or ion measurement where silver/silver chloride or calomel reference electrodes are used. However, saturated KCl is only sparingly soluble below 20°C, so if measurements below this temperature are to be carried out 3M Potassium Chloride remains in solution down to less than 10°C. Some electrode manufacturers recommend that the Potassium Chloride be saturated with Silver Chloride (AgCl) - A good electrolyte must fulfil a number of conditions. The equitransference of the cation/anion combination should be as close as possible to being equimobile, have constant chloride activity, be of high electrical conductance and be as non-chemically reactive as possible. Reagecon 3M Potassium Chloride Electrode Filling Solution Saturated with Silver Chloride is a high quality product that fulfils all of these criteria.
    Color and Shape:Liquid

    Ref: 07-EFS3AC5

    500ml
    100.00€
  • Reagecon GY1 to GY7 Colour Reference Set according to European Pharmacopoeia (EP)


    Reagecon’s GY1 to GY7 Colour Reference Set is formulated as a set of reference solutions for the examination of the degree of colour of liquids in accordance with the European Pharmacopoeia Chapter 2.2.2. These products are produced by combining Reagecon Primary Colour Solutions - Concentration verified using a high performance spectrophotometer
    Color and Shape:Liquid

    Ref: 07-EPRSGYAMPSET

    8x10ml
    266.00€
  • Reagecon Ion Chromatography (IC) Multi Element Anion Standard (7 Elements) in Water (H₂O)


    Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Fluoride (F⁻): 50 µg/mL (ppm). - Chloride (Cl⁻): 1000 µg/mL (ppm). - Bromide (Br⁻): 100 µg/mL (ppm). - Nitrite (NO₂): 20 µg/mL (ppm). - Nitrate (NO₃): 200 µg/mL (ppm). - Phosphate (PO₄³): 15 µg/mL (ppm). - Sulphate (SO₄²): 5000 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-ICA-LIS-601

    100ml
    1,487.00€
  • Reagecon Potassium Chloride 0.01M (0.01N) Analytical Volumetric Solution (AVL)


    Reagecon's Potassium Chloride 0.01M (0.01N) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for precipitation (argentometric) titrations.  This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete.  The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties.  Precipitation titrimetry is based on reactions that yield compounds of limited solubility. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.
    Color and Shape:Liquid

    Ref: 07-KCL20011

    1l
    255.00€
  • Reagecon Tellurium Standard for Atomic Absorption (AAS) 10,000 µg/mL (10,000 ppm) in 1M Hydrochloric Acid (HCl)


    Reagecon's Tellurium Standard for Atomic Absorption (AAS) 10;000 µg/mL in 1M Hydrochloric Acid (HCl) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.
    Color and Shape:Liquid

    Ref: 07-AATEM

    500ml
    272.00€
  • Ref: 07-KFECN10WV1

    1l
    84.00€
  • Reagecon Potassium Acetate TS Solution according to United States Pharmacopoeia (USP)


    Reagecon's Potassium Acetate TS Solution according to United States Pharmacopoeia (USP) is specified for use in individual United States Pharmacopoeia (USP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03); is NIST traceable and has guaranteed stability throughout its entire shelf life; even after opening the bottle.
    Color and Shape:Liquid

    Ref: 07-USP4505

    500ml
    91.00€
  • Reagecon Colour Reference Solution No.4 Orange Yellow according to Chinese Pharmacopoeia (ChP)


    Reagecon's Colour Reference Solution No.4 Orange Yellow is formulated as a reference solution for the examination of the degree of colouration of liquids in accordance with the Chinese Pharmacopoeia. This product is produced by combining Reagecon Primary Colour Solutions. - This Reference Colour Solution is a ready to use coloration standard presented in high quality, tamper evident bottles for use as a calibration and/or quality control standard. It is prepared by combining Reagecon Primary Colour Solutions. - Manufactured gravimetrically according to Chinese Pharmacopoeia guidelines. - Concentration verified using a high performance spectrophotometer.
    Color and Shape:Liquid

    Ref: 07-CPRCSOY401

    100ml
    112.00€
  • Reagecon Osmolality Standard 100 mOsm/Kg


    Reagecon's Osmolality Standard 100 mOsm/kg is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). The Osmolality results are reported in milliOsmoles per kilogram water (mOsm/kg H₂O shortened to mOsm/kg for routine use). This product is manufactured in compliance with European; United States and Chinese Pharmacopoeia guidelines where appropriate. - Manufactured in accordance with European and United States Pharmacopoeia guidelines where appropriate. - These standards are used for calibration; quality control; method validation and instrument calibration irrespective of brand. - Low Uncertainty of Measurement. - Manufactured to exacting specifications with an extended shelf life and stability. - Consistency of product - Independent; Traceable; Tested.
    Color and Shape:Liquid

    Ref: 07-RE-OSM10001

    100ml
    314.00€
  • Reagecon 0.1 NTU Non Ratio Turbidity Standard


    Reagecon 0.1 NTU Non Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for non-ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - These Turbidity Standards remove the handling; stability and accuracy problems associated with traditional Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …
    Color and Shape:Liquid

    Ref: 07-CRS-0.1-500

    500ml
    212.00€
  • Reagecon Refractive Index Standard (Stabilised Sucrose) 1.42009 nD units at 20°C


    Reagecon's Refractive Index Standards (Stabilised Sucrose) 1.42009 nD at 20°C is a high quality product, with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Refractive Index determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer, manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation for the test method used to certify this product. - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.00014 nD units. It is stable for one year; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.00014 nD units) - Tested using a state of the art Refractometer
    Color and Shape:Liquid

    Ref: 07-RIBS50S6

    6x15ml
    486.00€
  • Reagecon Indium Standard for Atomic Absorption (AAS) 10,000 µg/mL (10,000 ppm) in 1M Nitric Acid (HNO₃)


    Reagecon's Indium Standard for Atomic Absorption (AAS) 10;000 µg/mL in 1M Nitric Acid (HNO₃) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.
    Color and Shape:Liquid

    Ref: 07-AAINM

    500ml
    464.00€
  • Reagecon Ion Chromatography (IC) Multi Element Anion Standard (5 Elements) in Water (H₂O)


    Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Chlorine (Cl): 50 µg/mL (ppm). - Fluorine (F): 2.5 µg/mL (ppm). - Nitrate (NO₃): 25 µg/mL (ppm). - Phosphate (PO₄³): 1 µg/mL (ppm). - Sulphate (SO₄²): 50 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-ICA5-MIX9-100

    100ml
    377.00€
  • Reagecon Hydrochloric Acid 5.0M (5.0N) Analytical Volumetric Solution (AVL)


    Reagecon's Hydrochloric Acid 5.0M (5.0N) Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.
    Color and Shape:Liquid

    Ref: 07-H25005

    5l
    99.00€
  • Reagecon Hydrochloric Acid 0.1M (0.1N) Analytical Volumetric Solution (AVL)


    Reagecon's Hydrochloric Acid 0.1M (0.1N) Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.
    Color and Shape:Liquid

    Ref: 07-H20101

    1l
    17.00€
  • Reagecon Gardner 2 Colour Standard


    Reagecon's Gardner 2 Colour Standard can be used to calibrate, control, qualify or validate colour measurement instruments. This product which is specified in ASTM D1544, D 6166, AOCS Td 1a and MS 817 Part 10 is very applicable to similarly coloured liquids including several vegetable and mineral oils.
    Color and Shape:Liquid

    Ref: 07-GARD02

    500ml
    257.00€
  • Reagecon Nitric Acid Dilute Solution according to United States Pharmacopoeia (USP)


    Reagecon's Nitric Acid Dilute Solution according to United States Pharmacopoeia (USP) is specified for use in individual United States Pharmacopoeia (USP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03); is NIST traceable and has guaranteed stability throughout its entire shelf life; even after opening the bottle.
    Color and Shape:Liquid

    Ref: 07-USP6905

    500ml
    58.00€
  • Reagecon ICP, ICP-MS Multi Element Standard (6 Elements) in 2-5% Nitric Acid (HNO₃)


    Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Calcium (Ca): 20000 µg/mL (ppm). - Sodium (Na): 20000 µg/mL (ppm). - Potassium (K): 4000 µg/mL (ppm). - Magnesium (Mg): 4000 µg/mL (ppm). - Iron (Fe): 2000 µg/mL (ppm). - Manganese (Mn): 1000 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-REICPCAL6AG

    100ml
    487.00€
  • Reagecon ICP, ICP-MS Multi Element Tuning Standard (10 Elements) in 2-5% Nitric Acid (HNO₃), trace Hydrochloric Acid (HCl) and trace Hydrofluoric Acid (HF)


    Reagecon's ICP; ICP-MS Multi Element Standard in 2-5% HNO, trace HCl and trace HF is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Barium (Ba): 10 µg/mL (ppm). - Beryllium (Be): 10 µg/mL (ppm). - Cerium (Ce): 10 µg/mL (ppm). - Cobalt (Co): 10 µg/mL (ppm). - Indium (In): 10 µg/mL (ppm). - Lithium (Li): 10 µg/mL (ppm). - Magnesium (Mg): 10 µg/mL (ppm). - Lead (Pb): 10 µg/mL (ppm). - Rhodium (Rh): 10 µg/mL (ppm). - Titanium (Ti): 10 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-REICPTUNE10B

    100ml
    240.00€
  • Reagecon Sodium Thiosulphate 0.1M (0.1N) Analytical Volumetric Solution (AVL)


    Reagecon's Sodium Thiosulphate 0.1M (0.1N) Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for oxidation/reduction titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Oxidation/reduction titrations depend on changes in the electropotential of the oxidation reduction system and always involves a reaction between an oxidising and reducing pair. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.
    Color and Shape:Liquid

    Ref: 07-T20101

    1l
    21.00€
  • Reagecon Nickel Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)


    Reagecon's Nickel Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.
    Color and Shape:Liquid

    Ref: 07-PNI2A2

    100ml
    98.00€
  • Ref: 07-HSP1031

    1l
    143.00€
  • Reagecon Ammoniacal Potassium Ferricyanide TS Solution according to United States Pharmacopoeia (USP)

    CAS:
    Reagecon's Ammoniacal Potassium Ferricyanide TS Solution according to United States Pharmacopoeia (USP) is specified for use in individual United States Pharmacopoeia (USP) Monographs. It is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03); is NIST traceable and has guaranteed stability throughout its entire shelf life; even after opening the bottle.
    Color and Shape:Liquid

    Ref: 07-USP0501

    100ml
    35.00€
  • Reagecon Cobalt Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)


    Reagecon's Cobalt Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.
    Color and Shape:Liquid

    Ref: 07-PCO2A2

    100ml
    98.00€
  • Reagecon ICP, ICP-MS Multi Element Tuning Standard (23 Elements) in 2-5% Nitric Acid (HNO₃)


    Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2-5% HNO₃ is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Aluminium (Al): 100 µg/mL (ppm). - Boron (B): 100 µg/mL (ppm). - Barium (Ba): 100 µg/mL (ppm). - Beryllium (Be): 100 µg/mL (ppm). - Bismuth (Bi): 100 µg/mL (ppm). - Calcium (Ca): 100 µg/mL (ppm). - Cadmium (Cd): 100 µg/mL (ppm). - Cobalt (Co): 100 µg/mL (ppm). - Chromium (Cr): 100 µg/mL (ppm). - Copper (Cu): 100 µg/mL (ppm). - Iron (Fe): 100 µg/mL (ppm). - Gallium (Ga): 100 µg/mL (ppm). - Potassium (K): 100 µg/mL (ppm). - Lithium (Li): 100 µg/mL (ppm). - Magnesium (Mg): 100 µg/mL (ppm). - Manganese (Mn): 100 µg/mL (ppm). - Sodium (Na): 100 µg/mL (ppm). - Nickel (Ni): 100 µg/mL (ppm). - Lead (Pb): 100 µg/mL (ppm). - Selenium (Se): 100 µg/mL (ppm). - Strontium (Sr): 100 µg/mL (ppm). - Tellurium (Te): 100 µg/mL (ppm). - Thallium (Tl): 100 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-REICPTUNE23A

    100ml
    1,157.00€
  • Reagecon Atomic Absorption (AAS) Multi Element Standard (3 Elements) 1000 µg/mL (1000 ppm) in 2% Nitric Acid (HNO₃)


    Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Atomic Absorption Multi Element Standard is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Cadmium (Cd): 1000 µg/mL (ppm). - Lead (Pb): 1000 µg/mL (ppm). - Nickel (Ni): 1000 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-AA-BIB-3-100

    100ml
    317.00€
  • Reagecon Total Base Number (TBN) Standard 1.0 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix


    Reagecon Total Base Number (TBN) Standard 1.0 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This high quality standard can be used to calibrate; control or validate the methodology or equipment used to perform TBN testing according to ASTM Method D2896. - Produced in accordance with ASTM D2896. - Test method D2896 is used for both new and used petroleum products that may contain basic constituents that may be present as additives. - The test method D2896 may also be used as a measure of lubricant degradation; but any condemning limits based on the test must be established on an individual basis. - Standards are traceable to NIST. - The method has a very low uncertainty of measurement. - Stability is proven (either opened or unopened) for the shelf life of this product. - This Standard forms part of the linearity set of TBN Standards that range in value from 1.0 mg/g KOH in a synthetic base oil up to 70 mg/g KOH. - Consistency of product - Independent; Traceable; Certified.
    Color and Shape:Solid

    Ref: 07-RETBN1S

    3x100g
    761.00€
  • Reagecon Acetone 1% w/w in Water


    Color and Shape:Liquid

    Ref: 07-RACET0100

    500ml
    149.00€
  • Reagecon pH 9.22 Buffer Solution at 20°C in Twin Neck


    Reagecon's pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.
    Color and Shape:Liquid

    Ref: 07-10922CTT

    1l
    39.00€
  • Reagecon Ion Chromatography (IC) Multi Element Anion Standard (3 Elements) in Water (H₂O)


    Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Chloride (Cl⁻): 150 µg/mL (ppm). - Nitrate (NO₃): 100 µg/mL (ppm). - Sulphate (SO₄²): 500 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-ICA3-MIX2-500

    500ml
    685.00€
  • Reagecon pH 1.07 Antimony Buffer Solution at 25°C


    Reagecon’s Antimony pH Buffer Solution is phosphate free. This pH Buffer Solution is formulated for use in intra-gastric pH analysis using antimony or equivalent electrodes. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.
    Color and Shape:Liquid

    Ref: 07-10725050

    500ml
    59.00€
  • Reagecon Bromocresol Purple 0.04% Indicator Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)


    Reagecon's Bromocresol Purple 0.04% Indicator Solution is a high quality Indicator Solution produced from the highest quality raw materials and manufactured and tested under rigorous conditions. For manual titrations; indicator titrant or analyte change colour and this colour change is by far the most important method of end point detection, in such titrations. A high quality indicator solution such as Reagecon's facilitates end point detection, in a clear and unambiguous manner and is an imperative for accurate manual titrimetry.
    Color and Shape:Liquid

    Ref: 07-1012701

    100ml
    48.00€
  • Reagecon Total Base Number (TBN) Standard 30 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix


    Reagecon Total Base Number (TBN) Standard 30 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This high quality standard can be used to calibrate; control or validate the methodology or equipment used to perform TBN testing according to ASTM Method D2896. - Produced in accordance with ASTM D2896. - Test method D2896 is used for both new and used petroleum products that may contain basic constituents that may be present as additives. - The test method D2896 may also be used as a measure of lubricant degradation; but any condemning limits based on the test must be established on an individual basis. - Standards are traceable to NIST. - The method has a very low uncertainty of measurement. - Stability is proven (either opened or unopened) for the shelf life of this product. - This Standard forms part of the linearity set of TBN Standards that range in value from 1.0 mg/g KOH in a synthetic base oil up to 70 mg/g KOH. - Consistency of product - Independent; Traceable; Certified.
    Color and Shape:Solid

    Ref: 07-RETBN30

    50g
    319.00€
  • Reagecon Platinum-Cobalt (Hazen) 10 Colour Standard


    Reagecon's Platinum-Cobalt (Hazen) 10 Colour Standard can be used to calibrate, control, qualify or validate colour measurement instruments. This standard can be described as Platinum-Cobalt, Pt-Co, Hazen or APHA colour. All descriptions are interchangeable. This product is used extensively in the water industry and several other industries. The standard covers the requirements of ASTM Method D 1209.
    Color and Shape:Liquid

    Ref: 07-HAZ10

    1l
    135.00€
  • Reagecon ICP, ICP-MS Multi Element Standard (26 Elements) in 2-5% Nitric Acid (HNO₃)


    Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2-5% HNO₃ is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Silver (Ag): 10 µg/mL (ppm). - Aluminium (Al): 10 µg/mL (ppm). - Arsenic (As): 10 µg/mL (ppm). - Barium (Ba): 10 µg/mL (ppm). - Beryllium (Be): 10 µg/mL (ppm). - Calcium (Ca): 10 µg/mL (ppm). - Cadmium (Cd): 10 µg/mL (ppm). - Cobalt (Co): 10 µg/mL (ppm). - Chromium (Cr): 10 µg/mL (ppm). - Cesium (Cs): 10 µg/mL (ppm). - Copper (Cu): 10 µg/mL (ppm). - Iron (Fe): 10 µg/mL (ppm). - Gallium (Ga): 10 µg/mL (ppm). - Potassium (K): 10 µg/mL (ppm). - Lithium (Li): 10 µg/mL (ppm). - Magnesium (Mg): 10 µg/mL (ppm). - Manganese (Mn): 10 µg/mL (ppm). - Sodium (Na): 10 µg/mL (ppm). - Nickel (Ni): 10 µg/mL (ppm). - Lead (Pb): 10 µg/mL (ppm). - Rubidium (Rb): 10 µg/mL (ppm). - Selenium (Se): 10 µg/mL (ppm). - Strontium (Sr): 10 µg/mL (ppm). - Thallium (Tl): 10 µg/mL (ppm). - Uranium (U): 10 µg/mL (ppm). - Vanadium (V): 10 µg/mL (ppm).
    Color and Shape:Liquid

    Ref: 07-REICPCAL26A

    100ml
    1,245.00€
  • Reagecon pH 4.00 Colour Coded Buffer Solution at 25°C in Twin Neck


    Reagecon's pH Buffer Solution at 25°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.
    Color and Shape:Liquid

    Ref: 07-1040525CTT

    500ml
    31.00€
  • Reagecon Total Base Number (TBN) Standard 6.0 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix


    Reagecon Total Base Number (TBN) Standard 6.0 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This high quality standard can be used to calibrate; control or validate the methodology or equipment used to perform TBN testing according to ASTM Method D2896. - Produced in accordance with ASTM D2896. - Test method D2896 is used for both new and used petroleum products that may contain basic constituents that may be present as additives. - The test method D2896 may also be used as a measure of lubricant degradation; but any condemning limits based on the test must be established on an individual basis. - Standards are traceable to NIST. - The method has a very low uncertainty of measurement. - Stability is proven (either opened or unopened) for the shelf life of this product. - This Standard forms part of the linearity set of TBN Standards that range in value from 1.0 mg/g KOH in a synthetic base oil up to 70 mg/g KOH. - Consistency of product - Independent; Traceable; Certified.
    Color and Shape:Solid

    Ref: 07-RETBN6R

    100g
    521.00€
  • Reagecon Aluminium Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)


    Reagecon's Aluminium Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.
    Color and Shape:Liquid

    Ref: 07-PAL2C2

    500ml
    196.00€
  • Reagecon 0.5 mg/L C from USP 1,4-Benzoquinone Total Organic Carbon (TOC) Standard for Membrapure Analyser


    Reagecon's 0.5 mg/L C from USP 1,4- Benzoquinone Total Organic Carbon (TOC) Standard is a product of extremely high specification and purity. The product is produced from ultra pure raw materials including water that is prepared by a special proprietary process. The product is presented in bottles that are manufactured, cleaned and leached, by a special proprietary process specifically for the product.
    Color and Shape:Liquid

    Ref: 07-ISTOC1287

    500ml
    477.00€
  • Reagecon Calibration Kit to C USP Sucrose for Total Organic Carbon (TOC) suitable for use with Membrapure Analyser


    Reagecon's Calibration Kit to C USP Sucrose for Total Organic Carbon (TOC) is a product of extremely high specification and purity. The product is produced from ultra pure raw materials including water that is prepared by a special proprietary process. The product is presented in bottles that are manufactured, cleaned and leached, by a special proprietary process specifically for the product - The product RTOCRS1 from the table above is prepared gravimetrically on a weight/volume basis to a specification of ± 2%. Reagecon holds IEC/ISO 17025 accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). Products are tested using a high performance calibrated Total Organic Carbon Analyser (TOC Instrument); RTOCRS1 is tested within the scope of Reagecon’s ISO 17025 accredited test method (A2LA Ref: 6739.03) and RTOCW500 is not tested within the scope of the accredited test method. Item No - Description | Qty: - RTOCW500-TOC Standard USP Reagent Water Rw: 1. - RTOCRS1-TOC Standard USP Sucrose Solution: 1.
    Color and Shape:Liquid

    Ref: 07-ISTOC1178

    2x500ml
    694.00€
  • Reagecon Bromine (Bromate/Bromide) 0.05M (0.1N) Analytical Volumetric Solution (AVL)


    Reagecon's Bromine (Bromate/Bromide) 0.05M (0.1N) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for oxidation/reduction titrations.  This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete.  The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties.  Oxidation/reduction titrations depend on changes in the electropotential of the oxidation reduction system and always involves a reaction between an oxidising and reducing pair. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.
    Color and Shape:Liquid

    Ref: 07-BR20101

    1l
    55.00€