
Physicochemical Standards
Physicochemical standards are essential reference materials used to ensure the accuracy and reliability of various analytical measurements in scientific research and industrial applications. This category includes a wide range of standards such as conductivity standards, electrochemistry standards, and ICP-OES/ICP-MS standards and reagents, which are critical for precise elemental analysis and conductivity measurements. pH buffer solutions and total organic/inorganic carbon reagents are vital for maintaining pH levels and measuring carbon content in samples. Standards from European Pharmacopoeia (EP), United States Pharmacopoeia (USP), and other pharmacopoeias provide benchmarks for pharmaceutical quality control. Additional standards like turbidity, density, refractometry, and viscosity standards ensure accurate physical property measurements. Specialized standards, such as those for wine, dairy, and petrochemical industries, support quality control and regulatory compliance in specific sectors. These physicochemical standards play a crucial role in ensuring the validity and reproducibility of experimental results, supporting a wide range of applications from environmental monitoring to pharmaceutical testing and materials science.
Subcategories of "Physicochemical Standards"
- Colour Standards(74 products)
- Cryoscope Standards(10 products)
- Density Standards(107 products)
- Melting Point Standards(16 products)
- Osmolality Standards(27 products)
- Refractive Index Standards(96 products)
- Turbidity Standards(137 products)
- Viscosity Standards(75 products)
Found 3970 products of "Physicochemical Standards"
Sort by
The purity filter is not visible because current products do not have associated purity data for filtering.
Reagecon Potassium Phosphate pH 7.2 Dissolution Media in accordance to United States (USP) and European Pharmacopoeias ( EP) Concentrate
Reagecon's Potassium Phosphate pH 7.2 Dissolution Media Concentrate is presented in concentrate form. This concentrate measures 230.85ml in volume in each bottle and the contents of each bottle can be diluted to produce 6L of working solution in water. This diluted volume is the working Dissolution Medium. The product is prepared and when diluted can be used in accordance with relevant pharmacopoeia requirements. - This product is presented as a concentrate in order to facilitate easy shipping, storage and handling. - The pack contains 12 bottles, each of which has a volume of 230.85ml of solution, each 230.85ml bottle is diluted to give 6L of ready to use Dissolution Medium.Color and Shape:LiquidReagecon S8000 Kinematic Viscosity, Dynamic Viscosity and Density Standard to 100°C
Reagecon's S8000 Kinematic Viscosity, Dynamic Viscosity and Density Standard can be used to calibrate, control or validate all types of viscometers including capillary, flow cup, rotational, falling ball, falling/rising object, stabinger and vibrational viscometers.This Viscosity Standard and all Reagecon Viscosity Standards are reported to 4 significant figures on their Certificate of Analysis.Only 2 significant figures are shown here for expediency of layout. - This product has been tested according to ASTM method D 2162 for Kinematic Viscosity using Ubbelohde Master Viscometers. - The Density has been tested in accordance with ASTM method D4052 (Kinematic Viscosity x Density = Dynamic Viscosity). - Kinematic Viscosity values and Density values are traceable to the Primary Standard of pure water at 20°C as adopted by NIST. Temperature values are traceable via National Standards to the ITS-90 temperature scale.Color and Shape:LiquidReagecon Iodine 0.05M Solution according to Chinese Pharmacopoeia (ChP)
Reagecon's Iodine 0.05M is a fully factorised, high purity, stable product, developed and tested for titrations. This is an Analytical Volumetric Solution, also called titrant, standard titrant or standard solution. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations also called potentiometric titration, to determine the end points by detection of any of several properties as detailed in several ChP monographs. - Titration is a rapid, economical and versatile analytical tool. This Reagecon Analytical Volumetric Solution is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stochiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon pH 1.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Ammonium Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in Water (H₂O)
Reagecon's Ammonium Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in H₂O is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon 60 NTU Ratio Turbidity Standard
Reagecon 60 NTU Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon Potassium Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)
Reagecon's Potassium Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon pH 7.00 Colour Coded Buffer Solution at 20°C in Twin Neck
Reagecon's pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (4 Elements) in 5-10% Nitric Acid (HNO₃)
Reagecon's Multi Element Standard for ICP; ICP-MS in 5-10% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Barium (Ba): 700 µg/mL (ppm). - Chromium (Cr): 1100 µg/mL (ppm). - Copper (Cu): 300 µg/mL (ppm). - Lithium (Li): 250 µg/mL (ppm).Color and Shape:LiquidReagecon 1.8 NTU Non Ratio Turbidity Standard
Reagecon 1.8 NTU Non Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for non-ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - These Turbidity Standards remove the handling; stability and accuracy problems associated with traditional Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon Total Dissolved Solids (TDS) 100 mg/l Standard
Reagecon’s Total Dissolved Solids (TDS) 100 mg/L Standard is aqueous based, non-hazardous and accurate to a specification of ± 1%. The product because it is aqueous based, has a low temperature coefficient of variation and guaranteed stability throughout its entire shelf life, even after opening the bottle. The above TDS value is obtained by measurement of Conductivity at 25°C and conversion to TDS using a conversion factor of 0.45. Test Method used was TPCOND. Measurement taken by comparison with a standard prepared from National Institute of Standards and Technology (USA), Standard Reference Material 999 (Potassium Chloride). Electrode used for measurement: Platinised Platinum Dip Cell. Reference: ASTM D-1125 Method A. - This TDS standard is aqueous based, thereby eliminating any errors attributable to matrix mismatch. Each bottle is supplied with a comprehensive Certificate of Analysis. The low temperature coefficient of variation, reduces measurement errors and enables non-temperature controlled use and is suitable for field work - High accuracy ± 1% at 25°C, enables the standards to be used as calibrators and/or controls, in accordance with the most exacting industrial requirements - Guaranteed stability throughout entire shelf life, even after opening the bottle, eliminates the need to open a fresh bottle of standard every time it is usedColor and Shape:LiquidReagecon Fluoride TISAB IV Ionic Strength Adjuster Solution
The use of Reagecon's Fluoride TISAB IV Ionic Strength Adjuster (ISA) is necessary as an additive when using an Ion Selective Electrode (ISE) for the measurement of Fluoride. The ISA is added to both the Ion Selective Electrode Calibration Solution (ISE) and the sample; so as to keep the ionic strength of both standard and test high; eliminate matrix effects and suppress or eliminate interfering ions. - For use as an Ionic Strength Adjuster (ISA) when performing Fluoride TISAB IV measurement by Ion Selective Electrode (ISE) - Suppresses interfering ions; eliminates matrix; hysteresis and liquid junction potentials. - Eliminates or reduces error due to temperature co-efficient of variation between sample and calibration standard. - High ionic strength. - Aqueous matrix. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle.Color and Shape:LiquidReagecon Density Standard Premium Range 0.8207 g/mL at 40°C
This Reagecon Density Standard Premium Range 0.8207 g/mL at 40°C is manufactured and tested in accordance with ASTM D1480-12 for testing of density or relative density (specific and API gravity). It is tested by Bingham Pycnometry and can be used as a calibration or control standard for density measurement by pycnometer, vibrational, or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using Bingham Pycnometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 Accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). The density of the product is established and tested using high performance calibrated reference pycnometers. - High accuracy (± 0.00077 g/ml) - Tested using a fundamental measurement technique (Bingham Pycnometer)Color and Shape:LiquidReagecon Density Standard Quality Range 0.7454 g/mL at 50°C
This Reagecon Density Standard Quality Range 0.7454 g/mL at 50°C is manufactured and tested in accordance with ASTM D4052 for testing of density or relative density (specific and API gravity). It is tested by vibrational densitometer and can be used as a calibration or control standard for density measurement by vibrational or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using vibrational densitometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. The density of the product is established and tested using high performance calibrated vibrational densitometers. - High accuracy ± 0.16%Color and Shape:LiquidReagecon Ammonium Standard for Ion Chromatography (IC) 0.2 mg/mL (200 ppm) in Water (H₂O)
Reagecon's Ammonium Standard for Ion Chromatography (IC) 0.2 mg/mL (200 ppm) in H₂O is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Iodide Standard for Ion Chromatography (IC) 0.005 mg/mL (5 ppm) in Water (H₂O)
Reagecon's Iodide Standard for Ion Chromatography (IC) 0.005 mg/mL (5 ppm) in H₂O is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Refractive Index Standard (Solvent Based) 1.51248 nD units at 20°C
CAS:Reagecon's Refractive Index Standards (Solvent Based) 1.51248 nD at 20°C is a high quality product; with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Refractive Index determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer; manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for the test method. - High accuracy (± 0.00014 nD units) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon Total Acid Number (TAN) Standard 2.0 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix
Reagecon Total Acid Number (TAN) Standard 2.0 mg/g Potassium Hydroxide (KOH) in Synthetic Base Oil Matrix is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This high quality standard can be used to calibrate; control or validate the methodology or equipment used to perform TAN testing according to ASTM Method D664. - Produced in accordance with ASTM D664. - The TAN test method D664 is used to indicate relative changes that occur in oil during use under oxidising conditions regardless of the colour or other properties of the oil. - The test method D664 is also used as a guide in quality control of lubricating oil formulations or as a measure of lubricant degradation. - Standards are traceable to NIST. - The method has a very low uncertainty of measurement which is linked to the TAN value and is expressed as a percentage of that value. - Stability is proven (either opened or unopened) for the shelf life of this product. - This Standard forms part of the linearity set of TAN Standards that range in value from 0.5 mg/g KOH in a synthetic base oil up to 4.5 mg/g KOH. - Consistency of product - Independent; Traceable; Certified.Color and Shape:SolidReagecon Brix Standard (Stabilised) 60% at 20°C
Reagecon's Brix Standard (Stabilised) 60% at 20°C is a high quality product; with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Brix determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer; manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for the test method used to certify this product (TPR1A 01). - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.11%. It is stable for one year; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.11%) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (32 Elements) in 2-5% Nitric Acid (HNO₃), trace Hydrofluoric Acid (HF) and trace Hydrochloric Acid (HCl)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon's Multi Element Standard for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃); trace Hydrofluoric Acid (HF) and trace Hydrochloric Acid (HCl) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Antimony (Sb): 10 μg/mL (ppm). - Arsenic (As): 10 μg/mL (ppm). - Barium (Ba): 10 μg/mL (ppm). - Beryllium (Be): 10 μg/mL (ppm). - Bismuth (Bi): 10 μg/mL (ppm). - Boron (B): 10 μg/mL (ppm). - Cadmium (Cd): 10 μg/mL (ppm). - Chromium (Cr): 10 μg/mL (ppm). - Cobalt (Co): 10 μg/mL (ppm). - Copper (Cu): 10 μg/mL (ppm). - Dysprosium (Dy): 10 μg/mL (ppm). - Europium (Eu): 10 μg/mL (ppm). - Gadolinium (Gd): 10 μg/mL (ppm). - Hafnium (Hf): 10 μg/mL (ppm). - Holmium (Ho): 10 μg/mL (ppm). - Indium (In): 10 μg/mL (ppm). - Lead (Pb): 10 μg/mL (ppm). - Lithium (Li): 10 μg/mL (ppm). - Manganese (Mn): 10 μg/mL (ppm). - Molybdenum (Mo): 10 μg/mL (ppm). - Nickel (Ni): 10 μg/mL (ppm). - Niobium (Nb): 10 μg/mL (ppm). - Ruthenium (Ru): 10 μg/mL (ppm). - Samarium (Sm): 10 μg/mL (ppm). - Strontium (Sr): 10 μg/mL (ppm). - Tantalum (Ta): 10 μg/mL (ppm). - Thorium (Th): 10 μg/mL (ppm). - Tin (Sn): 10 μg/mL (ppm). - Titanium (Ti): 10 μg/mL (ppm). - Tungsten (W): 10 μg/mL (ppm). - Vanadium (V): 10 μg/mL (ppm). - Zirconium (Zr): 10 μg/mL (ppm).Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (6 Elements) in 15% Hydrochloric Acid (HCl), USP 232 Precious Metal Impurities B (with Os)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standard in 15% HCl is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Iridium (Ir): 100 µg/mL (ppm). - Osmium (Os): 100 µg/mL (ppm). - Palladium (Pd): 100 µg/mL (ppm). - Platinum (Pt): 100 µg/mL (ppm). - Rhodium (Rh): 100 µg/mL (ppm). - Ruthenium (Ru): 100 µg/mL (ppm).Color and Shape:LiquidReagecon Barium Chloride R1 Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Barium Chloride R1 Solution is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include the preparation of other reagents (4.1.1), use in identification reactions of ions and functional groups (2.3.1) and used as a reagent in the performance of tests outlined in several EP monographs. - NIST traceable - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Phenylhydrazine Hydrochloride Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
Reagecon Phenylhydrazine Hydrochloride Solution is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include use as a reagent in the performance of tests outlined in several EP monographs. - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (9 Elements) in 2-5% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2-5% Nitric Acid (HNO₃) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Arsenic (As): 10 µg/mL (ppm). - Cadmium (Cd): 10 µg/mL (ppm). - Cobalt (Co): 10 µg/mL (ppm). - Copper (Cu): 10 µg/mL (ppm). - Mercury (Hg): 10 µg/mL (ppm). - Lithium (Li): 10 µg/mL (ppm). - Nickel (Ni): 10 µg/mL (ppm). - Lead (Pb): 10 µg/mL (ppm). - Vanadium (V): 10 µg/mL (ppm).Color and Shape:LiquidReagecon Brix Standard (Stabilised) 7% at 20°C
Reagecon's Brix Standard (Stabilised) 7% at 20°C is a high quality product; with an extended shelf life to be used either as a calibrant or analytical control material for use in Refractive Index based methods for Brix determination. This product can be used on any make or model of refractometer. The product is tested using a state of the art refractometer; manufactured gravimetrically and is traceable. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for the test method used to certify this product (TPR1A 01). - Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.03) for testing Refractive Index (Brix standards) using refractometry. This product has an uncertainty of measurement of ± 0.11%. It is stable for one year; either opened or unopened and is presented in a convenient 15ml dropper bottle. The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - High accuracy (± 0.11%) - Tested using a state of the art RefractometerColor and Shape:LiquidReagecon Sulphuric Acid 0.13M (0.26N ) Analytical Volumetric Solution (AVL)
Reagecon's Sulphuric Acid 0.13M (0.26N ) Analytical Volumetric Solution (AVL) is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). This product is a fully factorised; high purity; stable product; developed and tested for acid/base titrations. This Analytical Volumetric Solution; also called titrant; standard titrant or standard solution; is tested to a specification of ± 0.1%. It is a reagent of known concentration; that is dispensed from a burette or other dispensing apparatus to a sample (analyte); until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations; or more commonly automatic titrations; to determine the end points by detection of any of several properties. Acid/base titrations; also called neutralisation titrations; are used to determine either the amount of acid/base in a sample or the substance that can be converted to an acid/base. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Concentrate to make Ammonium (NH4) 1ppm Standard Solution according to European Pharmacopoeia (EP) Chapter 4 (4.1.2) Limit Test
Reagecon's Concentrate to make Ammonium (NH4) 1ppm Standard Solution is used in the preparation of other reagents and as specified in individual monographs. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density to a specification of ± 0.2%. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Density Standard Premium Range 1.5799 g/mL at 20°C
This Reagecon Density Standard Premium Range 1.5799 g/mL at 20°C is manufactured and tested in accordance with ASTM D1480-12 for testing of density or relative density (specific and API gravity). It is tested by Bingham Pycnometry and can be used as a calibration or control standard for density measurement by pycnometer, vibrational, or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using Bingham Pycnometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 Accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). The density of the product is established and tested using high performance calibrated reference pycnometers. - High accuracy (± 0.00077 g/ml) - Tested using a fundamental measurement technique (Bingham Pycnometer)Color and Shape:LiquidReagecon Spectrophotometry Bandwidth Standard Blank (Ph.Eur) Ratio of 268.7nm Peak to 266.8nm Trough
Reagecon's Spectrophotometry Bandwidth Standard Blank (Ph.Eur) Ratio of 268.7nm Peak to 266.8nm Trough produces a series of peaks and troughs over a very narrow change of wavelength. It enables a plot to be plotted that displays a maximum trough at an absorbance of 0.15A.Color and Shape:LiquidReagecon pH 12.46 Buffer Solution at 25°C
Reagecon’s pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Clinical Standard Sodium 120mmol/l and Potassium 80mmol/l for Flame Photometry
Reagecon's Sodium 120mmol/l and Potassium 80mmol/l Standard for Flame Photometry is manufactured from ultra-pure salts. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2% for each cation. The results are reported in mg/L on the basis of weight. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (10 Elements) in 2-5% Nitric Acid (HNO₃)
Pricing displayed is Nett. For order quantities above 4 units, ask your sales contact for a quotation. Reagecon’s Multi Element Standards for ICP; ICP-MS in 2-5% HNO₃ is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Selenium (Se): 40 µg/mL (ppm). - Copper (Cu): 100 µg/mL (ppm). - Lithium (Li): 100 µg/mL (ppm). - Nickel (Ni): 100 µg/mL (ppm). - Strontium (Sr): 100 µg/mL (ppm). - Zinc (Zn): 100 µg/mL (ppm). - Aluminium (Al): 200 µg/mL (ppm). - Iron (Fe): 200 µg/mL (ppm). - Phosphorus (P): 500 µg/mL (ppm). - Boron (B): 1000 µg/mL (ppm).Color and Shape:LiquidReagecon Calcium Standard for Flame Photometry 10,000ppm
Reagecon’s Calcium Standard for Flame Photometry (10;000ppm) in H₂O is manufactured from ultra-pure salt. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Molybdenum Standard for Atomic Absorption (AAS) 1000 µg/mL (1000 ppm) in Water (H₂O)
Reagecon's Molybdenum Standard for Atomic Absorption (AAS) 1000 µg/mL in Water (H₂O) is manufactured from very pure metal or salt (at least 99.9%). This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; to a specification of ± 0.2%. The results are reported in mg/L on the basis of weight). Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards). The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Spectrophotometry Caffeine Absorbance/Transmission (Linearity) Standard 25 mg/L (5ml)
Reagecon Spectrophotometry Caffeine Absorbance/Transmission (Linearity) Standard 25 mg/L is a standard which gives a spectral scan at various wavelengths. - ACCREDITED CALIBRATION: Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for the calibration of laboratory balances. This accreditation underscores our commitment to quality and reliability.Color and Shape:LiquidReagecon Osmolality Standard 290 mOsm/Kg
Reagecon's Osmolality Standard 290 mOsm/kg is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03). The Osmolality results are reported in milliOsmoles per kilogram water (mOsm/kg H₂O shortened to mOsm/kg for routine use). This product is manufactured in compliance with European; United States and Chinese Pharmacopoeia guidelines where appropriate. - Manufactured in accordance with European and United States Pharmacopoeia guidelines where appropriate. - These standards are used for calibration; quality control; method validation and instrument calibration irrespective of brand. - Low Uncertainty of Measurement. - Manufactured to exacting specifications with an extended shelf life and stability. - Consistency of product - Independent; Traceable; Tested.Color and Shape:LiquidReagecon Ethanol Density Standard 20% v/v Ethanol/Water (Nominal Density 0.97356 g/mL)
Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (14 Elements) in 5% Nitric Acid (HNO₃) and 1% Hydrochloric Acid (HCl)
Reagecon’s Multi Element Standards for ICP; ICP-MS in 5% Nitric Acid (HNO₃) and 1% Hydrochloric Acid (HCl) is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 (A2LA Ref: 6739.02) accreditation for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Arsenic (As): 15 µg/mL (ppm). - Cadmium (Cd): 2 µg/mL (ppm). - Cobalt (Co): 5 µg/mL (ppm). - Lead (Pb): 5 µg/mL (ppm). - Copper (Cu): 300 µg/mL (ppm). - Mercury (Hg): 3 µg/mL (ppm). - Lithium (Li): 250 µg/mL (ppm). - Nickel (Ni): 20 µg/mL (ppm). - Palladium (Pd): 10 µg/mL (ppm). - Vanadium (V): 10 µg/mL (ppm). - Antimony (Sb): 90 µg/mL (ppm). - Tin (Sn): 600 µg/mL (ppm). - Chromium (Cr): 1100 µg/mL (ppm). - Molybdenum (Mo): 1500 µg/mL (ppm).Color and Shape:LiquidReagecon ICP, ICP-MS Multi Element Standard (12 Elements) in 2% Nitric Acid (HNO₃) and trace Hydrofluoric Acid (HF)
Reagecon’s Multi Element Standards for ICP; ICP-MS in 2% HNO₃ and trace HF is manufactured from ultra-pure metals or salts. This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Boron (B): 10 µg/mL (ppm). - Germanium (Ge): 10 µg/mL (ppm). - Molybdenum (Mo): 10 µg/mL (ppm). - Niobium (Nb): 10 µg/mL (ppm). - Phosphorus (P): 10 µg/mL (ppm). - Rhenium (Re): 10 µg/mL (ppm). - Sulfur (S): 10 µg/mL (ppm). - Silicon (Si): 10 µg/mL (ppm). - Tantalum (Ta): 10 µg/mL (ppm). - Titanium (Ti): 10 µg/mL (ppm). - Tungsten (W): 10 µg/mL (ppm). - Zirconium (Zr): 10 µg/mL (ppm).Color and Shape:LiquidReagecon Chloride Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in Water (H₂O)
Reagecon's Chloride Standard for Ion Chromatography (IC) 1 mg/mL (1000 ppm) in H₂O is manufactured from ultra-pure material. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density; to a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon holds ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Ion Chromatography (IC) Multi Element Anion Standard (7 Elements) in Water (H₂O)
Reagecon’s Multi Element Anion Standard for Ion Chromatography (IC) in H₂O is manufactured from ultra-pure salts. This product is manufactured gravimetrically. Prior to bottling; the final product is tested and verified using a state of the art ion chromatograph and is reported using the gravimetric result; corrected for density. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment; using ultra-pure water (specially treated for the production of ion chromatography standards) and triple leached pre-cleaned bottles. All of the uncertainties of measurement for the product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level. Description | Concentration: - Flerovium (Fl): 50 µg/mL (ppm). - Chloride (Cl⁻): 50 µg/mL (ppm). - Bromide (Br⁻): 50 µg/mL (ppm). - Nitrite (NO₂): 50 µg/mL (ppm). - Nitrate (NO₃): 50 µg/mL (ppm). - Phosphate (PO₄³): 50 µg/mL (ppm). - Sulphate (SO₄²): 50 µg/mL (ppm).Color and Shape:LiquidReagecon Cryoscope Standard 577 (-0.557°C) (577m°H)
Reagecon's Cryoscope Standard 577 (-0.557°C) (577m°H) is used to calibrate, control, verify or validate Cryoscopes. The product is manufactured for use on all Cryoscopes compliant to International Reference Standard ISO5764/IDF108 for the determination of freezing point in milk.Color and Shape:LiquidReagecon 1 NTU Non Ratio Turbidity Standard
Reagecon 1 NTU Non Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for non-ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - These Turbidity Standards remove the handling; stability and accuracy problems associated with traditional Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon Yttrium Standard for ICP, ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃)
Reagecon's Yttrium Standard for ICP; ICP-MS 1000 µg/mL (1000 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Benzethonium Chloride 0.04M (0.04N) Analytical Volumetric Solution (AVL)
Reagecon's Benzethonium Chloride 0.04M (0.04N) Analytical Volumetric Solution (AVL) is a fully factorised, high purity, stable product, developed and tested for titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.1%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stoichiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Density Standard Premium Range 0.9098 g/mL at 20°C
This Reagecon Density Standard Premium Range 0.9098 g/mL at 20°C is manufactured and tested in accordance with ASTM D1480-12 for testing of density or relative density (specific and API gravity). It is tested by Bingham Pycnometry and can be used as a calibration or control standard for density measurement by pycnometer, vibrational, or hydrometer (specific gravity) based techniques. - The Test Method used by Reagecon for testing density standards using Bingham Pycnometers is accredited to ISO 17025 (A2LA Ref: 6739.03). The product is prepared gravimetrically on a weight/weight basis. Both solute and solvent are weighed on a balance calibrated by OIML traceable weights. Reagecon holds ISO 17025 Accreditation for calibration of laboratory balances (A2LA Ref: 6739.02). The density of the product is established and tested using high performance calibrated reference pycnometers. - High accuracy (± 0.00077 g/ml) - Tested using a fundamental measurement technique (Bingham Pycnometer)Color and Shape:LiquidReagecon Hydrochloric Acid 0.1N according to United States Pharmacopoeia (USP)
Reagecon's Hydrochloric Acid 0.1N is a fully factorised, high purity, stable product, developed and tested for titrations. This Analytical Volumetric Solution, also called titrant, standard titrant or standard solution, is tested to a specification of ± 0.2%. It is a reagent of known concentration, that is dispensed from a burette or other dispensing apparatus to a sample (analyte), until a reaction between the two liquids is judged to be complete. The product may be used for manual titrations, or more commonly automatic titrations, to determine the end points by detection of any of several properties as detailed in several USP monographs. - Titration is a rapid, economical and versatile analytical tool. This Reagecon titrant is accurate, stable, reproducible and fully factorised. Titrations performed with this product, exhibit defined stochiometry, are quantitative, establish an equilibrium that is definitive and fast and provide unambiguous results. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:LiquidReagecon Iron Standard for ICP, ICP-MS 240 µg/mL (240 ppm) in 2-5% Nitric Acid (HNO₃)
Reagecon's Iron Standard for ICP; ICP-MS 240 µg/mL (240 ppm) in 2-5% Nitric Acid (HNO₃) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. Reagecon hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances. - GHS/OSHA compliant, REACH - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.Color and Shape:LiquidReagecon Zinc Chloride Solution Iodinated according to European Pharmacopoeia (EP) Chapter 4 (4.1.1)
CAS:Reagecon Zinc Chloride Solution Iodinated is a high purity stable product developed and tested for European Pharmacopoeia (EP) applications. These include use as a reagent in the performance of tests outlined in several EP monographs. - This Reagecon EP reagent is accurate, stable and reproducible. Stability is proven (either opened or unopened) for the shelf life of this product.Color and Shape:Liquid

