Electrochemistry Standards
Electrochemistry standards are critical reference materials used to ensure the accuracy and consistency of electrochemical measurements in research and industrial applications. These standards include a range of solutions and materials such as pH buffer solutions, turbidity standards, and conductivity standards, which are essential for calibrating instruments and validating methods. They support the maintenance of electrodes, ensure proper measurement of chemical oxygen demand (COD), and provide reliable redox standards for assessing oxidation-reduction potentials. Ionic strength adjustors and acid salts enhance the precision of electrochemical analyses, while physicochemical standards help in maintaining consistency across various testing environments. Proper care and calibration using these standards are vital for accurate electrochemical analysis, supporting applications in environmental monitoring, quality control, and scientific research. By providing reliable benchmarks, electrochemistry standards play a crucial role in achieving high-quality, reproducible results in electrochemical studies and applications.
Subcategories of "Electrochemistry Standards"
- Chemical Oxygen Demand Standards(26 products)
- Conductivity Standards(1,056 products)
- Electrode Care and Maintenance(36 products)
- Ionic Strength Adjustors(10 products)
- Redox. Standards(25 products)
- pH Buffer Solutions(758 products)
Found 790 products of "Electrochemistry Standards"
Sort by
Purity (%)
0
100
|
0
|
50
|
90
|
95
|
100
Reagecon 10 NTU Ratio Turbidity Standard
Reagecon 10 NTU Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon 40 NTU Turbiform™ Stabilised Formazin Turbidity Standard
This standard is an aqueous suspension of a formazin type product that carries all of the advantages of formazin but eliminates its shortcomings. It is stable; safe; EPA approved and accurate. - Reagecon have developed a proprietary synthetic process that produces a family of products called Turbiform™. These products combine most of the positive attributes of the formazin and AMCO APEA-1 range of standards already available from Reagecon; whilst eliminating most of the shortcomings. Most importantly; this process does not interfere adversely with the status of formazin as the recognised primary standard. - Product exhibits a wide range of particle sizes; shapes and slopes (similar to formazin) mean diameter 3 µm with distribution of between 1 and 20 microns; which are similar to the particle size and distribution found in most sample types. - This product can be used to calibrate; control; validate or qualify; almost any make or model of Turbidity measuring instrument. - Traceable to NIST reference material 1690 and 1691 - Can be used to calibrate; control; validate or qualify almost any make or model of instrumentColor and Shape:LiquidReagecon pH 7.00 Technical Colour Coded Buffer Solution at 25°C
Reagecon’s Technical pH Buffer Solution at 25°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 50 NTU Non Ratio Turbidity Standard
Reagecon 50 NTU Non Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for non-ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - These Turbidity Standards remove the handling; stability and accuracy problems associated with traditional Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon 350,000 µS/cm Conductivity Standard at 25°C (CDt)
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon 40 NTU Non Ratio Turbidity Standard
Reagecon 40 NTU Non Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for non-ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - These Turbidity Standards remove the handling; stability and accuracy problems associated with traditional Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon 100 NTU Turbiform™ Stabilised Formazin Turbidity Standard
This standard is an aqueous suspension of a formazin type product that carries all of the advantages of formazin but eliminates its shortcomings. It is stable; safe; EPA approved and accurate. - Reagecon have developed a proprietary synthetic process that produces a family of products called Turbiform™. These products combine most of the positive attributes of the formazin and AMCO APEA-1 range of standards already available from Reagecon; whilst eliminating most of the shortcomings. Most importantly; this process does not interfere adversely with the status of formazin as the recognised primary standard. - Product exhibits a wide range of particle sizes; shapes and slopes (similar to formazin) mean diameter 3 µm with distribution of between 1 and 20 microns; which are similar to the particle size and distribution found in most sample types. - This product can be used to calibrate; control; validate or qualify; almost any make or model of Turbidity measuring instrument. - Traceable to NIST reference material 1690 and 1691 - Can be used to calibrate; control; validate or qualify almost any make or model of instrumentColor and Shape:LiquidReagecon pH 7.000 High Resolution Colour Coded Buffer Solution at 20°C
Reagecon's High Resolution Colour Coded pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 358 mV Redox Oxidation/Reduction (ORP) Standard at 25°C
This Reagecon's 358 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 358 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.Color and Shape:LiquidReagecon pH 6.86 Colour Coded Buffer Solution at 25°C in Twin Neck
Reagecon's pH Buffer Solution at 25°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 3M Potassium Chloride Electrode Filling Solution (Electrolyte) Free from Silver Ion
Concentrated or saturated Potassium Chloride (KCl) is the optimal electrolyte and filling solution for potentiometric titrations, direct pH measurement, redox or ion measurement where silver/silver chloride or calomel reference electrodes are used. However, saturated KCl is only sparingly soluble below 20°C, so if measurements below this temperature are to be carried out 3M Potassium Chloride remains in solution down to less than 10°C. - A good electrolyte must fulfil a number of conditions. The equitransference of the cation/anion combination should be as close as possible to being equimobile, have constant chloride activity, be of high electrical conductance and be as non-chemically reactive as possible. Reagecon 3M Potassium Chloride Electrode Filling Solution is a high quality product that fulfils all of these criteria.Color and Shape:LiquidReagecon pH 9.00 Colour Coded Buffer Solution at 20°C
Reagecon's pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 10.00 Mercury Free Colour Coded Buffer Solution at 25°C
Reagecon’s Mercury Free pH Buffer Solution at 25°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 100 µS/cm Conductivity Standard at 25°C (CDt)
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon pH 8.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 4.000 High Resolution Colour Coded Buffer Solution at 20°C
Reagecon's High Resolution Colour Coded pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH Buffer Solution pH 7.00 ± 0.01 @ 38°C
Reagecon's pH Buffer Solution at 38°C is tested and NIST traceable.Color and Shape:LiquidReagecon 200 NTU Ratio Turbidity Standard
Reagecon 200 NTU Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon pH 11.00 Buffer Solution at 25°C in Twin Neck
Reagecon's pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 4.00 Colour Coded Buffer Solution at 25°C in Twin Neck
Reagecon's pH Buffer Solution at 25°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 1.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 4.00 Buffer Solution at 25°C
Reagecon’s pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 4 NTU Non Ratio Turbidity Standard
Reagecon 4 NTU Non Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for non-ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - These Turbidity Standards remove the handling; stability and accuracy problems associated with traditional Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon pH 7.00 Mercury Free Buffer Solution at 25°C
Reagecon’s Mercury Free pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Total Dissolved Solids (TDS) 2000 mg/l Standard
Reagecon’s Total Dissolved Solids (TDS) 2000 mg/L Standard is aqueous based, non-hazardous and accurate to a specification of ± 1%. The product because it is aqueous based, has a low temperature coefficient of variation and guaranteed stability throughout its entire shelf life, even after opening the bottle. The above TDS value is obtained by measurement of Conductivity at 25°C and conversion to TDS using a conversion factor of 0.45. Test Method used was TPCOND. Measurement taken by comparison with a standard prepared from National Institute of Standards and Technology (USA), Standard Reference Material 999 (Potassium Chloride). Electrode used for measurement: Platinised Platinum Dip Cell. Reference: ASTM D-1125 Method A. - This TDS standard is aqueous based, thereby eliminating any errors attributable to matrix mismatch. Each bottle is supplied with a comprehensive Certificate of Analysis. The low temperature coefficient of variation, reduces measurement errors and enables non-temperature controlled use and is suitable for field work - High accuracy ± 1% at 25°C, enables the standards to be used as calibrators and/or controls, in accordance with the most exacting industrial requirements - Guaranteed stability throughout entire shelf life, even after opening the bottle, eliminates the need to open a fresh bottle of standard every time it is usedColor and Shape:LiquidReagecon 2 NTU Ratio Turbidity Standard
Reagecon 2 NTU Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon pH 2.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 10.00 Colour Coded Buffer Solution at 20°C in Twin Neck
Reagecon's pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 3M Potassium Chloride Electrode Filling Solution (Electrolyte) Free from Silver Ion
Concentrated or saturated Potassium Chloride (KCl) is the optimal electrolyte and filling solution for potentiometric titrations, direct pH measurement, redox or ion measurement where silver/silver chloride or calomel reference electrodes are used. However, saturated KCl is only sparingly soluble below 20°C, so if measurements below this temperature are to be carried out 3M Potassium Chloride remains in solution down to less than 10°C. - A good electrolyte must fulfil a number of conditions. The equitransference of the cation/anion combination should be as close as possible to being equimobile, have constant chloride activity, be of high electrical conductance and be as non-chemically reactive as possible. Reagecon 3M Potassium Chloride Electrode Filling Solution is a high quality product that fulfils all of these criteria.Color and Shape:LiquidReagecon pH 8.00 Buffer Solution at 25°C
Reagecon’s pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 7.00 Colour Coded Buffer Solution at 25°C in Twin Neck
Reagecon's pH Buffer Solution at 25°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 4000 NTU Ratio Turbidity Standard
Reagecon 4000 NTU Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon 468 mV Redox Oxidation/Reduction (ORP) Standard at 25°C in Twin Neck
This Reagecon's 468 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 468 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.Color and Shape:LiquidReagecon Resistivity A 0.1% Ammonium Chloride Solution at 25°C, according IEC 60112:2020
Color and Shape:LiquidReagecon pH 6.881 NIST Value Buffer Solution at 20°C in Bag-in-Box
Reagecon’s NIST Value pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 300 µS/cm Conductivity Standard at 25°C (CDt)
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:LiquidReagecon pH 7.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 4.001 NIST Value Buffer Solution at 20°C
Reagecon’s NIST Value pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Chemical Oxygen Demand (COD) 1% w/v Silver Sulphate in Sulphuric Acid
Chemical Oxygen Demand (COD) 1% Silver Sulphate in Sulphuric Acid (conc.) provides the primary and secondary digestion catalysts for oxidation of carbon during chemical oxidation.Color and Shape:LiquidReagecon 220 mV Redox Oxidation/Reduction (ORP) Standard at 25°C
This Reagecon's 220 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 220 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.Color and Shape:LiquidReagecon 400 mV Redox Oxidation/Reduction (ORP) Standard at 25°C
This Reagecon's 400 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 400 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.Color and Shape:LiquidReagecon pH 4.005 DIN 19266 Buffer Solution at 25°C in Bag-in-Box
Reagecon's DIN 19266 pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 40 NTU Ratio Turbidity Standard
Reagecon 40 NTU Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon pH 6.00 Buffer Solution at 20°C
Reagecon’s pH Buffer Solution at 20°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 4.000 High Resolution Buffer Solution at 25°C
Reagecon's High Resolution pH Buffer Solution at 25°C is tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 5 NTU Non Ratio Turbidity Standard
Reagecon 5 NTU Non Ratio Turbidity Standard is a suspension of polymer microspheres. The product has guaranteed stability throughout its entire shelf life; even after opening the bottle. - Reagecon’s Turbidity Standards for non-ratio instruments are composed of suspended polymer microspheres; with well defined spherical shape. - Designed and formulated to overcome the adverse safety; accuracy and stability issues experienced with Formazin Turbidity Standards. - These Turbidity Standards remove the handling; stability and accuracy problems associated with traditional Formazin Turbidity Standards. - Traceable to NIST standard reference materials. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - US EPA approved for drinking water turbidity. - Non-toxic and non-carcinogenic. - Reagecon also offers a range of Stabilised Formazin Turbidity Standards which are marketed under the Turbiform™ brand See More …Color and Shape:LiquidReagecon pH 10.00 Colour Coded Buffer Solution at 20°C
Reagecon's pH Buffer Solution at 20°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 4.00 Recal Colour Coded Buffer Solution at 25°C
Reagecon's pH Buffer Solution at 25°C is colour coded for ease of use. Tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon 3M Potassium Chloride Electrode Filling Solution Saturated with Silver Chloride (Electrolyte)
Concentrated or saturated Potassium Chloride (KCl) is the optimal electrolyte and filling solution for potentiometric titrations, direct pH measurement, redox or ion measurement where silver/silver chloride or calomel reference electrodes are used. However, saturated KCl is only sparingly soluble below 20°C, so if measurements below this temperature are to be carried out 3M Potassium Chloride remains in solution down to less than 10°C. Some electrode manufacturers recommend that the Potassium Chloride be saturated with Silver Chloride (AgCl) - A good electrolyte must fulfil a number of conditions. The equitransference of the cation/anion combination should be as close as possible to being equimobile, have constant chloride activity, be of high electrical conductance and be as non-chemically reactive as possible. Reagecon 3M Potassium Chloride Electrode Filling Solution Saturated with Silver Chloride is a high quality product that fulfils all of these criteria.Color and Shape:LiquidReagecon 50,000 µS/cm Conductivity Standard at 25°C (CDt)
Reagecon's Conductivity Standard at 25°C is tested by an ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity senors; quality control; method validation and instrument qualification. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST standard reference materials; meets the specification requirements of all the major Pharmacopoeias. - Each bottle is supplied with a comprehensive Certificate of Analysis and has a table of conductivity variation with temperature available via the product label; as are lot numbers and expiry dates for user convenience. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of standard every time it is used.Color and Shape:Liquid