
Electrochemistry Standards
Electrochemistry standards are critical reference materials used to ensure the accuracy and consistency of electrochemical measurements in research and industrial applications. These standards include a range of solutions and materials such as pH buffer solutions, turbidity standards, and conductivity standards, which are essential for calibrating instruments and validating methods. They support the maintenance of electrodes, ensure proper measurement of chemical oxygen demand (COD), and provide reliable redox standards for assessing oxidation-reduction potentials. Ionic strength adjustors and acid salts enhance the precision of electrochemical analyses, while physicochemical standards help in maintaining consistency across various testing environments. Proper care and calibration using these standards are vital for accurate electrochemical analysis, supporting applications in environmental monitoring, quality control, and scientific research. By providing reliable benchmarks, electrochemistry standards play a crucial role in achieving high-quality, reproducible results in electrochemical studies and applications.
Subcategories of "Electrochemistry Standards"
- Chemical Oxygen Demand Standards(26 products)
- Conductivity Standards(1,056 products)
- Electrode Care and Maintenance(36 products)
- Ionic Strength Adjustors(10 products)
- Redox. Standards(25 products)
- pH Buffer Solutions(758 products)
Found 790 products of "Electrochemistry Standards"
Sort by
Purity (%)
0
100
|
0
|
50
|
90
|
95
|
100
Potassium chloride, 0.00017M, Conductivity Standard
CAS:<p>This Thermo Scientific Chemicals brand product was originally part of the Alfa Aesar product portfolio. Some documentation and label information may refer to the legacy brand. The original Alfa Aesar product / item code or SKU reference has not changed as a part of the brand transition to Thermo Scientific Chemicals.</p>Formula:ClKColor and Shape:liquid, Colorless, clearMolecular weight:74.55Potassium tetrakis(4-chlorophenyl)borate
CAS:Formula:C24H16BCl4KPurity:98%Color and Shape:SolidMolecular weight:496.1051Reagecon Conductivity Standard 500 µS/cm at 25°C ISO 17034 Certified Reference Material
Reagecon's Conductivity Standard at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity sensors; quality control; method validation and instrument qualification. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST Standard Reference Materials; meets the specification requirements of all the major Pharmacopoeias. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the Standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of Standard every time it is used.Color and Shape:LiquidReagecon Conductivity Standard 1000 µS/cm at 25°C ISO 17034 Certified Reference Material
Reagecon's Conductivity Standard at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity sensors; quality control; method validation and instrument qualification. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST Standard Reference Materials; meets the specification requirements of all the major Pharmacopoeias. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the Standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of Standard every time it is used.Color and Shape:LiquidReagecon pH 6.86 Buffer Solution at 25°C in Twin Neck
Reagecon's pH Buffer Solution at 25°C tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Conductivity Standard 200 µS/cm at 25°C ISO 17034 Certified Reference Material
Reagecon's Conductivity Standard at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity sensors; quality control; method validation and instrument qualification. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST Standard Reference Materials; meets the specification requirements of all the major Pharmacopoeias. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the Standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of Standard every time it is used.Color and Shape:LiquidReagecon Ammonia 1ppm as NH₃ Ion Selective Electrode Standard
Reagecon's Ammonia 1ppm as as NH₃ Ion Selective Electrode Standard can be used at suitable concentrations to calibrate or control measurements that use Ion Selective Electrodes (ISE’s) as the sensing technology. - Reagecon’s Ion Selective Electrode (ISE) Standards; diluted to a suitable concentration; are particularly suitable for use as a calibration or control material; using Ion Selective Electrodes as the sensing technology. - Accurate to ± 0.5%. - Aqueous matrix. - Directly traceable to NIST standard reference materials. - Can be used for Method Validation or Instrument Qualification. - Can also be used as a calibrant for other techniques. - Safe; compatible with all types of ISE Electrodes. - Manufactured to exacting specifications with an extended shelf life & stability; even after opening the bottle.Color and Shape:LiquidReagecon Conductivity Standard 147 µS/cm at 25°C ISO 17034 Certified Reference Material
Reagecon's Conductivity Standard at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity sensors; quality control; method validation and instrument qualification. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST Standard Reference Materials; meets the specification requirements of all the major Pharmacopoeias. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the Standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of Standard every time it is used.Color and Shape:LiquidReagecon Conductivity Standard 1413 µS/cm at 25°C ISO 17034 Certified Reference Material
Reagecon's Conductivity Standard at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity sensors; quality control; method validation and instrument qualification. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST Standard Reference Materials; meets the specification requirements of all the major Pharmacopoeias. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the Standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of Standard every time it is used.Color and Shape:LiquidReagecon Lead 1000ppm Ion Selective Electrode Standard
Reagecon's Lead 1000ppm Ion Selective Electrode Standard can be used at suitable concentrations to calibrate or control measurements that use Ion Selective Electrodes (ISE’s) as the sensing technology. - Reagecon’s Ion Selective Electrode (ISE) Standards; diluted to a suitable concentration; are particularly suitable for use as a calibration or control material; using Ion Selective Electrodes as the sensing technology. - Accurate to ± 0.5%. - Aqueous matrix. - Directly traceable to NIST standard reference materials. - Can be used for Method Validation or Instrument Qualification. - Can also be used as a calibrant for other techniques. - Safe; compatible with all types of ISE Electrodes. - Manufactured to exacting specifications with an extended shelf life & stability; even after opening the bottle.Color and Shape:LiquidReagecon Conductivity Standard 50 µS/cm at 25°C ISO 17034 Certified Reference Material
Reagecon's Conductivity Standard at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. The product is aqueous based; non-hazardous and accurate to a specification of ± 1%. - To enable analysts to achieve the correct result when measuring conductivity and to prove the correctness of that result; Reagecon has developed a high quality range of Conductivity Standards; which can be used for calibration of conductivity sensors; quality control; method validation and instrument qualification. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control. - Reagecon Conductivity Standards are aqueous based; thereby eliminating any errors attributable to matrix mismatch. - Directly traceable to NIST Standard Reference Materials; meets the specification requirements of all the major Pharmacopoeias. - The low temperature coefficient of variation; reduces measurement errors and enables non-temperature controlled use and is suitable for field work. - High accuracy ± 1% at 25°C; enables the Standards to be used as calibrators and/or controls; in accordance with the most exacting industrial requirements. - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle thereby eliminating the requirement to open a fresh bottle of Standard every time it is used.Color and Shape:LiquidReagecon pH 4.01 Buffer Solution at 25°C in Twin Neck
Reagecon's pH Buffer Solution at 25°C tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon pH 10.01 Buffer Solution at 25°C in Twin Neck
Reagecon's pH Buffer Solution at 25°C tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Fluoride 50 ppm Ion Selective Electrode Standard
Reagecon's Fluoride 50 ppm Ion Selective Electrode Standard can be used at suitable concentrations to calibrate or control measurements that use Ion Selective Electrodes (ISE’s) as the sensing technology. - Reagecon’s Ion Selective Electrode (ISE) Standards; diluted to a suitable concentration; are particularly suitable for use as a calibration or control material; using Ion Selective Electrodes as the sensing technology. - Accurate to ± 0.5%. - Aqueous matrix. - Directly traceable to NIST standard reference materials. - Can be used for Method Validation or Instrument Qualification. - Can also be used as a calibrant for other techniques. - Safe; compatible with all types of ISE Electrodes. - Manufactured to exacting specifications with an extended shelf life & stability; even after opening the bottle.Color and Shape:LiquidReagecon Fluoride 200 ppm Ion Selective Electrode Standard
Reagecon's Fluoride 200 ppm Ion Selective Electrode Standard can be used at suitable concentrations to calibrate or control measurements that use Ion Selective Electrodes (ISE’s) as the sensing technology. - Reagecon’s Ion Selective Electrode (ISE) Standards; diluted to a suitable concentration; are particularly suitable for use as a calibration or control material; using Ion Selective Electrodes as the sensing technology. - Accurate to ± 0.5%. - Aqueous matrix. - Directly traceable to NIST standard reference materials. - Can be used for Method Validation or Instrument Qualification. - Can also be used as a calibrant for other techniques. - Safe; compatible with all types of ISE Electrodes. - Manufactured to exacting specifications with an extended shelf life & stability; even after opening the bottle.Color and Shape:LiquidReagecon pH 9.21 Buffer Solution at 25°C in Twin Neck
Reagecon's pH Buffer Solution at 25°C tested by our ISO 17025 Accredited Test Method (A2LA Ref: 6739.03) and NIST traceable.Color and Shape:LiquidReagecon Fluoride 0.8 ppm Ion Selective Electrode Standard
Reagecon's Fluoride 0.8 ppm Ion Selective Electrode Standard can be used at suitable concentrations to calibrate or control measurements that use Ion Selective Electrodes (ISE’s) as the sensing technology. - Reagecon’s Ion Selective Electrode (ISE) Standards; diluted to a suitable concentration; are particularly suitable for use as a calibration or control material; using Ion Selective Electrodes as the sensing technology. - Accurate to ± 0.5%. - Aqueous matrix. - Directly traceable to NIST standard reference materials. - Can be used for Method Validation or Instrument Qualification. - Can also be used as a calibrant for other techniques. - Safe; compatible with all types of ISE Electrodes. - Manufactured to exacting specifications with an extended shelf life & stability; even after opening the bottle.Color and Shape:LiquidReagecon Sodium 100 ppm Ion Selective Electrode Standard
Reagecon's Sodium 100 ppm Ion Selective Electrode Standard can be used at suitable concentrations to calibrate or control measurements that use Ion Selective Electrodes (ISE’s) as the sensing technology. - Reagecon’s Ion Selective Electrode (ISE) Standards; diluted to a suitable concentration; are particularly suitable for use as a calibration or control material; using Ion Selective Electrodes as the sensing technology. - Accurate to ± 0.5%. - Aqueous matrix. - Directly traceable to NIST standard reference materials. - Can be used for Method Validation or Instrument Qualification. - Can also be used as a calibrant for other techniques. - Safe; compatible with all types of ISE Electrodes. - Manufactured to exacting specifications with an extended shelf life & stability; even after opening the bottle.Color and Shape:LiquidReagecon Fluoride 1000ppm Ion Selective Electrode Standard
Reagecon's Fluoride 1000ppm Ion Selective Electrode Standard can be used at suitable concentrations to calibrate or control measurements that use Ion Selective Electrodes (ISE’s) as the sensing technology. - Reagecon’s Ion Selective Electrode (ISE) Standards; diluted to a suitable concentration; are particularly suitable for use as a calibration or control material; using Ion Selective Electrodes as the sensing technology. - Accurate to ± 0.5%. - Aqueous matrix. - Directly traceable to NIST standard reference materials. - Can be used for Method Validation or Instrument Qualification. - Can also be used as a calibrant for other techniques. - Safe; compatible with all types of ISE Electrodes. - Manufactured to exacting specifications with an extended shelf life & stability; even after opening the bottle.Color and Shape:LiquidReagecon Carbonate pH 8.00 Borax Free Buffer Standard at 25°C ISO 17034 Certified Reference Material
Reagecon Carbonate pH 8.00 Borax Free Buffer Standard at 25°C Certified Reference Material is produced under our ISO 17034 (A2LA Ref: 6739.01) Accreditation and is NIST traceable. - ISO 17034 accreditation requirements include raw material characterisation; homogeneity and stability studies; assignment of certified values as well as packaging and documentation control.Color and Shape:Liquid



