Redox. Standards

Redox. Standards

Redox standards are used to calibrate and verify the performance of electrochemical systems that measure oxidation-reduction potential (ORP). These standards provide a reference for determining the redox state of various solutions in environmental, industrial, and research settings. CymitQuimica offers a broad range of redox standards to ensure accurate ORP measurements, supporting a wide range of electrochemical applications.

Found 25 products of "Redox. Standards"

Sort by

The purity filter is not visible because current products do not have associated purity data for filtering.
products per page.
  • Reagecon 300 mV Redox Oxidation/Reduction (ORP) Standard at 25°C


    This Reagecon's 300 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 300 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.
    Color and Shape:Liquid

    Ref: 07-RS300

    500ml
    71.00€
  • Reagecon 220 mV Redox Oxidation/Reduction (ORP) Standard at 25°C


    This Reagecon's 220 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 220 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.
    Color and Shape:Liquid

    Ref: 07-RS220

    500ml
    71.00€
  • Reagecon 250 mV Redox Oxidation/Reduction (ORP) Standard at 25°C


    This Reagecon's 250 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 250 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.
    Color and Shape:Liquid

    Ref: 07-RS25010

    10l
    897.00€
  • Reagecon 468 mV Redox Oxidation/Reduction (ORP) Standard at 25°C in Twin Neck


    This Reagecon's 468 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 468 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.
    Color and Shape:Liquid

    Ref: 07-RS46825TT

    250ml
    54.00€
  • Reagecon 124 mV Redox Oxidation/Reduction (ORP) Standard at 25°C


    This Reagecon 124 mV (± 5mV) Standard acts as a Control or Reference Material. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. This Standard verifies the functionality of the sensing and reference electrode; the analysts technique; environmental conditions and the operation of the measuring meter. The value of 124 mV quoted refers to the potentials of the platinum electrode v Ag/AgCl reference electrode. - Reagecon produces a complete range of high-quality Redox Standards for the control; validation or qualification of Redox measurement. - Very high specification (± 5mV). - Manufactured to exacting specifications with an extended shelf life and stability; even after opening the bottle. - All products are tested with proven verifiable accuracy and fully budgeted uncertainty of measurement.
    Color and Shape:Liquid

    Ref: 07-RS12410

    10l
    897.00€